Application of partial least-squares regression to near-infrared reflectance spectroscopic determination of shive content in flax

被引:11
|
作者
Sohn, M
Barton, FE
Morrison, WH
Archibald, DD
机构
[1] ARS, USDA, Richard B Russell Agr Res Ctr, Athens, GA 30605 USA
[2] Penn State Univ, Dept Crop & Soil Sci, University Pk, PA 16802 USA
关键词
flax fiber; shive; near-infrared spectroscopy; chemometrics; NIRS;
D O I
10.1366/000370203321666588
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Shive, the nonfiberous core portion of the stem, in flax fiber after retting is related to fiber quality. The objective of this study is to develop a standard calibration model for determining shive content in retted flax by using near-infrared reflectance spectroscopy. Calibration samples were prepared by manually mixing pure, ground shive and pure, ground fiber from flax retted by three different methods (water, dew, and enzyme retting) to provide a wide range of shive content from 0 to 100%. Partial least-squares (PLS) regression was used to generate a calibration model, and spectral data were processed using various pretreatments such as a multiplicative scatter correction (MSC), normalization, derivatives, and Martens' Uncertainty option to improve the calibration model. The calibration model developed with a single sample set resulted in a standard error of 1.8% with one factor. The best algorithm was produced from first-derivative processing of the spectral data. MSC was not effective processing for this model. However, a big bias was observed when independent sample sets were applied to this calibration model to predict shive content in flax fiber. The calibration model developed using a combination sample set showed a slightly higher standard error and number of factors compared to the model for a single sample set, but this model was sufficiently accurate to apply to each sample set. The best algorithm for the combination sample set was generated from second derivatives followed by MSC processing of spectral data and from Martens' Uncertainty option; it resulted in a standard error of 2.3% with 2 factors. The value of the digital second derivative centered at 1674 nm for these spectral data was highly correlated to shive content of flax and could form the basis for a simple, low-cost sensor for the shive or fiber content in retted flax.
引用
收藏
页码:551 / 556
页数:6
相关论文
共 50 条
  • [31] Improving the Robustness and Stability of Partial Least Squares Regression for Near-infrared Spectral Analysis
    Shao Xueguang
    Chen Da
    Xu Heng
    Liu Zhichao
    Cai Wensheng
    [J]. CHINESE JOURNAL OF CHEMISTRY, 2009, 27 (07) : 1328 - 1332
  • [32] Determination of quercetin in extracts of Ginkgo biloba L. leaves by near-infrared reflectance spectroscopy based on interval partial least-squares (iPLS) model
    Zhou, Xiaohua
    Xiang, Bingren
    Wang, Zhirnei
    Zhang, Mei
    [J]. ANALYTICAL LETTERS, 2007, 40 (16-18) : 3383 - 3391
  • [33] Genetic algorithm-based method for selecting wavelengths and model size for use with partial least-squares regression: Application to near-infrared spectroscopy
    Bangalore, AS
    Shaffer, RE
    Small, GW
    Arnold, MA
    [J]. ANALYTICAL CHEMISTRY, 1996, 68 (23) : 4200 - 4212
  • [34] Reflectance Near-Infrared Spectroscopic Method with a Chemometric Technique Using Partial Least Squares Multivariate Calibration for Simultaneous Determination of Chondroitin, Glucosamine, and Ascorbic Acid
    El-Gindy, Alaa
    Attia, Khalid Abdel-Salam
    Nassar, Mohammad Wafaa
    El-Abasawy, Nasr M. A.
    Shoeib, Maisra Al-Shabrawi
    [J]. JOURNAL OF AOAC INTERNATIONAL, 2012, 95 (03) : 724 - 732
  • [35] Application of latent root regression for calibration in near-infrared spectroscopy. Comparison with principal component regression and partial least squares
    Vigneau, E
    Bertrand, D
    Qannari, EM
    [J]. CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1996, 35 (02) : 231 - 238
  • [36] Application of Partial Least-Squares Regression in Seasonal Streamflow Forecasting
    Abudu, Shalamu
    King, J. Phillip
    Pagano, Thomas C.
    [J]. JOURNAL OF HYDROLOGIC ENGINEERING, 2010, 15 (08) : 612 - 623
  • [37] Partial least-squares near-infrared determination of hydrocarbons removed from polluted waters by using tanned solid wastes
    Gammoun, A.
    Moros, J.
    Tahiri, S.
    Garrigues, S.
    de la Guardia, M.
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 385 (04) : 766 - 770
  • [38] Determination of Protein Secondary Structure from Infrared Spectra Using Partial Least-Squares Regression
    Wilcox, Kieaibi E.
    Blanch, Ewan W.
    Doig, Andrew J.
    [J]. BIOCHEMISTRY, 2016, 55 (27) : 3794 - 3802
  • [39] Partial least-squares near-infrared determination of hydrocarbons removed from polluted waters by using tanned solid wastes
    A. Gammoun
    J. Moros
    S. Tahiri
    S. Garrigues
    M. de la Guardia
    [J]. Analytical and Bioanalytical Chemistry, 2006, 385 : 766 - 770
  • [40] Simultaneous determination of human serum albumin, γ-globulin, and glucose in a phosphate buffer solution by near-infrared spectroscopy with moving window partial least-squares regression
    Kasemsumran, S
    Du, YP
    Murayama, K
    Huehne, M
    Ozaki, Y
    [J]. ANALYST, 2003, 128 (12) : 1471 - 1477