CO2-controlled sampling of alveolar gas in mechanically ventilated patients

被引:100
|
作者
Schubert, JK [1 ]
Spittler, KH [1 ]
Braun, G [1 ]
Geiger, K [1 ]
Guttmann, J [1 ]
机构
[1] Univ Hosp Freiburg, Dept Anesthesiol & Intens Care Med, D-79106 Freiburg, Germany
关键词
acetone; breath analysis; isoflurane; isoprene; pentane;
D O I
10.1152/jappl.2001.90.2.486
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
A newly designed gas-sampling device using end-tidal CO2 to separate dead space gas from alveolar gas was evaluated in 12 mechanically ventilated patients. For that purpose, CO2-controlled sampling was compared with mixed expiratory sampling. Alveolar sampling valves were easily controlled via CO2 concentration. Concentrations of four volatile substances were determined in the expired and inspired gas. Isoflurane and isoprene, which did not occur in the inspired air, had ratios of end-tidal to mixed expired concentrations of 1.75 and 1.81, respectively. Acetone and pentane, found in both the inspired and expired air, showed ratios of 0.96 and 1.0, respectively. Precision of concentration measurements was between 2.4% (isoprene) and 11.2% (isoflurane); reproducibility las coefficient of variation) was 5%. Because the only possible source of isoflurane and isoprene in this setting was patients' blood, selective enrichment of alveolar gas was demonstrated. By using the new sampling technique, sensitivity of breath analysis was nearly doubled.
引用
收藏
页码:486 / 492
页数:7
相关论文
共 50 条
  • [21] Optimization of Endotracheal Tube Cuff Pressure by Monitoring CO2 Levels in the Subglottic Space in Mechanically Ventilated Patients: A Randomized Controlled Trial
    Efrati, Shai
    Bolotin, Gil
    Levi, Leon
    Zaaroor, Menashe
    Guralnik, Ludmila
    Weksler, Natan
    Levinger, Uriel
    Soroksky, Md Arie
    Denman, William T.
    Gurman, Gabriel M.
    ANESTHESIA AND ANALGESIA, 2017, 125 (04): : 1309 - 1315
  • [22] The effect of Shiatsu massage on agitation in mechanically ventilated patients: A randomized controlled trial
    Harorani, Mehdi
    Garshasbi, Masoumeh
    Sediqi, Mohamad
    Farahani, Zohreh
    Habibi, Danial
    Farahani, Mahtab
    Amini, Nazanin
    Velashjerdi, Zahra
    HEART & LUNG, 2021, 50 (06): : 893 - 897
  • [23] DESIGN AND VALIDATION OF AN INDICATOR GAS INJECTOR FOR MULTIPLE GAS WASHOUT TESTS IN MECHANICALLY VENTILATED PATIENTS
    HUYGEN, PEM
    FEENSTRA, BWA
    HOLLAND, WPJ
    INCE, C
    STAM, H
    BRUINING, HA
    CRITICAL CARE MEDICINE, 1990, 18 (07) : 754 - 759
  • [24] EVALUATION OF AN EQUIPMENT FOR CONTINUOUS GAS-EXCHANGE MONITORING IN MECHANICALLY VENTILATED PATIENTS
    CARLSSON, M
    FORSBERG, E
    THORNE, A
    NORDENSTROM, J
    HEDENSTIERNA, G
    JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 1984, 8 (01) : 93 - 93
  • [25] Comparison of two methods to assess blood CO2 equilibration curve in mechanically ventilated patients
    Cavaliere, F
    Giovannini, N
    Chiarla, C
    Conti, G
    Pennisi, MA
    Montini, L
    Gaspari, R
    Proietti, R
    RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY, 2005, 146 (01) : 77 - 83
  • [26] Carbonic anhydrases are upstream regulators of CO2-controlled stomatal movements in guard cells
    Hu, Honghong
    Boisson-Dernier, Aurelien
    Israelsson-Nordstroem, Maria
    Boehmer, Maik
    Xue, Shaowu
    Ries, Amber
    Godoski, Jan
    Kuhn, Josef M.
    Schroeder, Julian I.
    NATURE CELL BIOLOGY, 2010, 12 (01) : 87 - U234
  • [27] Alternative to arterial blood gas sampling to assess oxygenation status in mechanically ventilated patients with severe coronavirus disease 2019: An exploratory analysis
    Goudarzi, Sogand
    Mukerji, Shivali
    Reich, John Adam
    Nozari, Ala
    Quraishi, Sadeq
    ANESTHESIA AND ANALGESIA, 2022, 134 : 325 - 326
  • [28] Design and Modelling of a Continuum Robot for Distal Lung Sampling in Mechanically Ventilated Patients in Critical Care
    Mitros, Zisos
    Thamo, Balint
    Bergeles, Christos
    da Cruz, Lyndon
    Dhaliwal, Kevin
    Khadem, Mohsen
    FRONTIERS IN ROBOTICS AND AI, 2021, 8
  • [29] Simple device for the sampling of alveolar CO2
    Goiffon, R
    COMPTES RENDUS DES SEANCES DE LA SOCIETE DE BIOLOGIE ET DE SES FILIALES, 1928, 99 : 377 - 377
  • [30] Validation of Math Model Using Porous Media for Determining Alveolar CO2 in Ventilated Patients
    Jimenez-Posada, L. D.
    Palacio-Sanchez, A. F.
    Montagut-Ferizzola, Y. J.
    Ardila-Villegas, M.
    Maya, Juan C.
    CRITICAL CARE MEDICINE, 2024, 52 (10) : e503 - e511