中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Blood flow rate is a critical parameter for diagnosing dialysis access function during fistulography where a flow rate of 600 ml/min in arteriovenous graft or 400-500 ml/min in arteriovenous fistula is considered the clinical threshold for fully functioning access. In this study, a flow rate computational model for calculating intra-access flow to evaluate dialysis access patency was developed and validated in an in vitro set up using digital subtraction angiography. Flow rates were computed by tracking the bolus through two regions of interest using cross correlation (XCOR) and mean arrival time (MAT) algorithms, and correlated versus an in-line transonic flow meter measurement. The mean difference (mean. standard deviation) between XCOR and in-line flow measurements for in vitro setup at 3, 6, 7.5 and 10 frames/s was 118 +/- 63; 37 +/- 59; 31 +/- 31; and 46.+/- 57 ml/min respectively while for MAT method it was 86 +/- 56; 57 +/- 72; 35 +/- 85; and 19 +/- 129 ml/min respectively. The result of this investigation will be helpful for selecting candidate algorithms while blood flow computational tool is developed for clinical application.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Blood Flow Simulation in a Giant Intracranial Aneurysm and Its Validation by Digital Subtraction Angiography
    Ho, Harvey
    Wu, Jian
    Hunter, Peter
    COMPUTATIONAL BIOMECHANICS FOR MEDICINE: SOFT TISSUES AND THE MUSCULOSKELETAL SYSTEM, 2011, : 15 - 26
  • [42] DUPLEX ULTRASONOGRAPHY, DIGITAL SUBTRACTION ANGIOGRAPHY, AND CONVENTIONAL ANGIOGRAPHY IN ASSESSING CAROTID ATHEROSCLEROSIS
    GLOVER, JL
    BENDICK, PJ
    JACKSON, VP
    BECKER, GJ
    DILLEY, RS
    HOLDEN, RW
    ARCHIVES OF SURGERY, 1984, 119 (06) : 664 - 669
  • [43] Quantification of volumetric coronary blood flow with dual-energy digital subtraction angiography
    Molloi, S
    Ersahin, A
    Tang, J
    Hicks, J
    Leung, CY
    CIRCULATION, 1996, 93 (10) : 1919 - 1927
  • [44] CORONARY BLOOD-FLOW VELOCITY IN MAN - PRELIMINARY-RESULTS USING DIGITAL SUBTRACTION CORONARY ANGIOGRAPHY
    WHITE, HJ
    OHLEY, WJ
    SRINIVASAN, L
    MOST, AS
    WILLIAMS, DO
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1986, 12 (04): : 283 - 283
  • [45] DUPLEX ULTRASOUND SCANNING IN THE ASSESSMENT OF ARTERIOVENOUS-FISTULAS CREATED FOR HEMODIALYSIS ACCESS - COMPARISON WITH DIGITAL SUBTRACTION ANGIOGRAPHY
    TORDOIR, JHM
    DEBRUIN, HG
    HOENEVELD, H
    EIKELBOOM, BC
    KITSLAAR, PJEHM
    JOURNAL OF VASCULAR SURGERY, 1989, 10 (02) : 122 - 128
  • [46] THE CEPHALIC VEIN AS AN ACCESS ROUTE IN INTRAVENOUS DIGITAL SUBTRACTION ANGIOGRAPHY
    SMITH, DC
    ROLD, KD
    HEWES, RC
    MERA, SS
    BRITISH JOURNAL OF RADIOLOGY, 1985, 58 (691): : 670 - 672
  • [47] Evaluation of intra-aneurysmal blood flow by digital subtraction angiography: Blood flow change after coil embolization
    Asakura, F
    Tenjin, H
    Sugawa, N
    Kimura, S
    Oki, F
    Yonekawa, Y
    SURGICAL NEUROLOGY, 2003, 59 (04): : 310 - 319
  • [48] DIGITAL SUBTRACTION ANGIOGRAPHY WITH DYNAMIC COLOR FUNCTION IMAGES
    HAENDLE, H
    HAENDLE, J
    MAASS, W
    FINKLER, K
    DIGITALE BILDDIAGNOSTIK, 1984, 4 (04): : 153 - 157
  • [49] PARAMETRIC IMAGING USING DIGITAL SUBTRACTION ANGIOGRAPHY
    HUNTER, GJS
    HUNTER, JV
    BROWN, NJG
    BRITISH JOURNAL OF RADIOLOGY, 1986, 59 (697): : 7 - 11
  • [50] INTRAVENOUS ANGIOGRAPHY USING DIGITAL VIDEO SUBTRACTION
    OVITT, TW
    CAPP, MP
    CHRISTENSON, PC
    FISHER, HD
    FROST, M
    NUDELMAN, S
    ROEHRIG, H
    SEELEY, G
    INVESTIGATIVE RADIOLOGY, 1980, 15 (05) : 408 - 408