Blood Flow Measurement using Digital Subtraction Angiography for Assessing Hemodialysis Access Function

被引:4
|
作者
Koirala, Nischal [1 ,2 ]
Setser, Randolph M. [3 ]
Bullen, Jennifer [4 ]
McLennan, Gordon [2 ]
机构
[1] Cleveland State Univ, Dept Chem & Biomed Engn, Cleveland, OH 44115 USA
[2] Cleveland Clin, Dept Biomed Engn, Cleveland, OH 44106 USA
[3] Siemens Med Solut USA Inc, Cleveland, OH USA
[4] Cleveland Clin, Dept Quantitat Hlth Sci, Cleveland, OH 44106 USA
关键词
Blood flow; bolus tracking algorithm; cross correlation; digital subtraction angiography; flow phantom; hemodialysis access; indicator-dilution principle; thermodilution; DOPPLER ULTRASOUND; VELOCITY; QUANTIFICATION; CONTRAST; VALIDATION; ARTERIES;
D O I
10.1117/12.2253929
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Blood flow rate is a critical parameter for diagnosing dialysis access function during fistulography where a flow rate of 600 ml/min in arteriovenous graft or 400-500 ml/min in arteriovenous fistula is considered the clinical threshold for fully functioning access. In this study, a flow rate computational model for calculating intra-access flow to evaluate dialysis access patency was developed and validated in an in vitro set up using digital subtraction angiography. Flow rates were computed by tracking the bolus through two regions of interest using cross correlation (XCOR) and mean arrival time (MAT) algorithms, and correlated versus an in-line transonic flow meter measurement. The mean difference (mean. standard deviation) between XCOR and in-line flow measurements for in vitro setup at 3, 6, 7.5 and 10 frames/s was 118 +/- 63; 37 +/- 59; 31 +/- 31; and 46.+/- 57 ml/min respectively while for MAT method it was 86 +/- 56; 57 +/- 72; 35 +/- 85; and 19 +/- 129 ml/min respectively. The result of this investigation will be helpful for selecting candidate algorithms while blood flow computational tool is developed for clinical application.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] DIGITAL SUBTRACTION ANGIOGRAPHY SYSTEMS - ASSESSING PERFORMANCE WITH PHANTOMS
    GOODSITT, MM
    ABBATE, L
    HESSELINK, JR
    RADIOLOGY, 1985, 156 (03) : 811 - 815
  • [32] Evaluation of intra-aneurysmal blood flow by time density curve using digital subtraction angiography
    Tenjin, H
    Asakura, F
    Nakahara, Y
    Matsumoto, K
    Matsuo, T
    Urano, F
    Ueda, S
    STROKE, 1998, 29 (01) : 311 - 311
  • [33] ABSOLUTE VOLUMETRIC BLOOD-FLOW MEASUREMENTS USING DUAL-ENERGY DIGITAL SUBTRACTION ANGIOGRAPHY
    MOLLOI, S
    QIAN, YJ
    ERSAHIN, A
    MEDICAL PHYSICS, 1993, 20 (01) : 85 - 91
  • [34] HEMODIALYSIS GRAFTS - COLOR DOPPLER FLOW IMAGING CORRELATED WITH DIGITAL SUBTRACTION ANGIOGRAPHY AND FUNCTIONAL STATUS
    DOUSSET, V
    GRENIER, N
    DOUWS, C
    SENUITA, P
    SASSOUSTE, G
    ADA, L
    POTAUX, L
    RADIOLOGY, 1991, 181 (01) : 89 - 94
  • [35] EVALUATION OF LEFT-VENTRICULAR FUNCTION USING DIGITAL SUBTRACTION ANGIOGRAPHY
    KOZUKA, T
    OHTA, M
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1985, 49 (07): : 710 - 718
  • [36] HYSTEROSALPINGOGRAPHY USING DIGITAL SUBTRACTION ANGIOGRAPHY
    SIEGMUNDSCHULTZE, E
    JASPERS, V
    BLEIL, M
    HOTZINGER, H
    SPATLING, L
    QUAKERNACK, K
    ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 1993, 254 (1-4) : 195 - 196
  • [37] Evaluation of changes of intracranial blood flow after carotid artery stenting using digital subtraction angiography flow assessment
    Wada, Hajime
    Saito, Masato
    Kamada, Kyousuke
    WORLD JOURNAL OF RADIOLOGY, 2015, 7 (02): : 45 - 51
  • [38] The measurement of hemodialysis access blood flow rates by the hemodynamic monitor
    Lindsay, RM
    Blake, PG
    Malek, P
    Posen, G
    Martin, B
    Bradfield, E
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1996, 7 (09): : A0830 - A0830
  • [39] The Measurement of Hemodialysis Access Blood Flow by a Conductivity Step Method
    Lindsay, Robert M.
    Huang, Shih-Han S.
    Sternby, Jan
    Hertz, Thomas
    CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2010, 5 (09): : 1602 - 1606
  • [40] A comparison of methods for the measurement of hemodialysis access recirculation and access blood flow rate
    Lindsay, RM
    Bradfield, E
    Rothera, C
    Kianfar, C
    Malek, P
    Blake, PG