Acute Coronary Syndrome after 17 Years of Bare Metal Stent Implantation: "Very" Very Late Stent Thrombosis

被引:4
|
作者
Rao, Raghavendra K. [1 ]
Reddy, S. [1 ]
Kashyap, J. R. [1 ]
Vikas, K. [1 ]
Reddy, Hithesh [1 ]
Ramalingam, Vadivelu [2 ]
机构
[1] Govt Med Coll & Hosp, Dept Cardiol, Sect 32, Chandigarh 160030, India
[2] Velammal Med Coll Hosp & Res Inst, Dept Cardiol, Madurai 625009, Tamil Nadu, India
关键词
ELUTING STENTS; EFFICACY;
D O I
10.1155/2020/9628719
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Very late stent thrombosis (VLST) is a catastrophic and life-threatening complication after percutaneous coronary intervention which presents as an acute coronary syndrome with significantly high mortality and morbidity. VLST is a rare entity with drug-eluting stents and even rarer with bare metal stents. The exact pathophysiologic mechanism of VLST after BMS implantation is not known although various mechanisms have been proposed. Recently, in-stent neoatherosclerosis with intimal plaque rupture has been proposed as a potential mechanism of VLST after BMS. We report a rare case of VLST occurring 17 years after BMS implantation with angiographic and intravascular imaging evidence which provides insight into the mechanisms of VLST.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Very late thrombosis in a bare metal stent: An under-recognized problem
    Fineschi, Massimo
    Gori, Tommaso
    CANADIAN JOURNAL OF CARDIOLOGY, 2008, 24 (02) : E6 - E7
  • [42] Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation
    Cook, Stephane
    Wenaweser, Peter
    Togni, Mario
    Billinger, Michael
    Morger, Cyrill
    Seiler, Christian
    Vogel, Rolf
    Hess, Otto
    Meier, Bernhard
    Windecker, Stephan
    CIRCULATION, 2007, 115 (18) : 2426 - 2434
  • [43] Very Late (10-Year-Old) Bare Metal Stent Thrombosis
    Shaw, Eric Scot
    Singh, Vikas
    Martinezclark, Pedro
    O'Neill, William W.
    CARDIOLOGY, 2010, 115 (02) : 127 - 129
  • [44] Integrity® coronary stent: A very limber bare-metal stent
    Belardi, Jorge A.
    Albertal, Mariano
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2011, 78 (06) : 909 - 909
  • [45] Optical Frequency Domain Imaging of Very Late Stent Thrombosis Following Bare-Metal Stent Implantation for Acute Myocardial Infarction A Case Report
    Masuda, Shinichiro
    Shibui, Takashi
    Kawamura, Ryuki
    Saiki, Hitoshi
    Hata, Akihiro
    INTERNATIONAL HEART JOURNAL, 2018, 59 (01) : 209 - 212
  • [46] Very late thrombosis after sirolimus-eluting stent implantation
    Pasceri, Vincenzo
    Pelliccia, Francesco
    Cianfrocca, Cinzia
    Pristipino, Christian
    Santini, Massimo
    Richichi, Giuseppe
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2006, 7 (06) : 438 - 442
  • [47] A case of very late thrombosis of bare metal stent successfully treated with Excimer Laser Coronary Angioplasty
    Larosa, Claudio
    Ricco, Annalisa
    Cosentino, Nicola
    Marino, Marcello
    Mongiardo, Rocco
    Niccoli, Giampaolo
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2010, 145 (02) : E60 - E63
  • [48] Very late stent thrombosis with bare-metal stent: identifying severe stent malapposition and underexpansion by intravascular ultrasound
    Caixeta, Adriano
    Salomon Palma Braga, Vanessa Cristina
    Mintz, Gary S.
    EINSTEIN-SAO PAULO, 2013, 11 (03): : 364 - 366
  • [49] Very late bare metal stent thrombosis in the setting of discontinuation of optimal medical therapy for 2 years
    Murai, Kota
    Sakata, Kenji
    Mabuchi, Tomohito
    Yamaguchi, Masato
    Mori, Masayuki
    Hayashi, Kenshi
    Kawashiri, Masa-Aki
    CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2018, 8 (02) : 186 - 189
  • [50] Late stent malapposition after drug eluting stent implantation is related to high incidence of very late stent thrombosis
    Qian, J. Y.
    Zhang, F.
    Wu, H. Y.
    Fan, B.
    Wang, Q. B.
    Ge, L.
    Ge, J. B.
    EUROPEAN HEART JOURNAL, 2007, 28 : 328 - 328