Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation

被引:673
|
作者
Cook, Stephane [1 ]
Wenaweser, Peter [1 ]
Togni, Mario [1 ]
Billinger, Michael [1 ]
Morger, Cyrill [1 ]
Seiler, Christian [1 ]
Vogel, Rolf [1 ]
Hess, Otto [1 ]
Meier, Bernhard [1 ]
Windecker, Stephan [1 ]
机构
[1] Univ Hosp Bern, Dept Cardiol, CH-3010 Bern, Switzerland
关键词
coronary disease; imaging; patients; stents; ultrasonics;
D O I
10.1161/CIRCULATIONAHA.106.658237
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background - Stent thrombosis may occur late after drug-eluting stent (DES) implantation, and its cause remains unknown. The present study investigated differences of the stented segment between patients with and without very late stent thrombosis with the use of intravascular ultrasound. Methods and Results - Since January 2004, patients presenting with very late stent thrombosis (> 1 year) after DES implantation underwent intravascular ultrasound. Findings in patients with very late stent thrombosis were compared with intravascular ultrasound routinely obtained 8 months after DES implantation in 144 control patients, who did not experience stent thrombosis for >= 2 years. Very late stent thrombosis was encountered in 13 patients at a mean of 630 +/- 166 days after DES implantation. Compared with DES controls, patients with very late stent thrombosis had longer lesions (23.9 +/- 16.0 versus 13.3 +/- 7.9 mm; P < 0.001) and stents (34.6 +/- 22.4 versus 18.6 +/- 9.5 mm; P < 0.001), more stents per lesion (1.6 +/- 0.9 versus 1.1 +/- 0.4; P < 0.001), and stent overlap (39% versus 8%; P < 0.001). Vessel cross-sectional area was similar for the reference segment (cross-sectional area of the external elastic membrane: 18.9 +/- 6.9 versus 20.4 +/- 7.2 mm(2); P=0.46) but significantly larger for the in-stent segment (28.6 +/- 11.9 versus 20.1 +/- 6.7 mm(2); P=0.03) in very late stent thrombosis patients compared with DES controls. Incomplete stent apposition was more frequent (77% versus 12%; P < 0.001) and maximal incomplete stent apposition area was larger (8.3 +/- 7.5 versus 4.0 +/- 3.8 mm(2); P=0.03) in patients with very late stent thrombosis compared with controls. Conclusions - Incomplete stent apposition is highly prevalent in patients with very late stent thrombosis after DES implantation, suggesting a role in the pathogenesis of this adverse event.
引用
收藏
页码:2426 / 2434
页数:9
相关论文
共 50 条
  • [1] Incidence and predictors of very late Stent thrombosis after drug-eluting stent implantation
    Suh, Jon
    Lee, Seung-Whan
    Kim, Jeong-Hoon
    Park, Duk-Woo
    Lee, Jong-Young
    Kim, Young-Hak
    Lee, Cheol Whan
    Hong, Mveong-Ki
    Kim, Jae-Joong
    Park, Seong-Wook
    Park, Seung-Jung
    AMERICAN JOURNAL OF CARDIOLOGY, 2007, 100 (8A): : 113L - 113L
  • [2] Speculative Mechanisms for Very Late Stent Thrombosis After Drug-Eluting Stent Implantation
    Nakagawa, Yoshihisa
    CIRCULATION JOURNAL, 2011, 75 (04) : 779 - 780
  • [3] Very Late Stent Thrombosis 11 Years after Implantation of a Drug-Eluting Stent
    Liou, Kevin
    Jepson, Nigel
    TEXAS HEART INSTITUTE JOURNAL, 2015, 42 (05) : 487 - 490
  • [4] The conundrum of late and very late stent thrombosis following drug-eluting stent implantation
    Garg, Pallav
    Mauri, Laura
    CURRENT OPINION IN CARDIOLOGY, 2007, 22 (06) : 565 - 571
  • [5] A Case of Very Late Stent Thrombosis 11 Years After Drug-Eluting Stent Implantation
    Vijayvergiya, Rajesh
    Kumar, Basant
    Kasinadhuni, Ganesh
    Mohanty, Soumitra
    JOURNAL OF INVASIVE CARDIOLOGY, 2019, 31 (08): : E261 - E262
  • [6] Predictors for very late stent thrombosis after drug-eluting stent implantation in diabetic patients
    Vouidris, Vassilis
    Kariofillis, Panagiotis
    Thomopoulou, Sophia
    Patsilinakos, Sotiris
    Manginas, Athanasios
    Spargias, Constantinos
    Pavlides, Gregory
    Cokkinos, Dennis V.
    EUROINTERVENTION, 2009, 4 (04) : 485 - 491
  • [7] Predictors for very late stent thrombosis after drug-eluting stent implantation in diabetic patients
    Voudris, Vassilis
    Karyofillis, Panagiotis
    Thomopoulou, Sophia
    Patsilinakos, Sotitrios
    Manginas, Athanasios
    Spargias, Constantinos
    Pavides, Gregory
    Cokkinos, Dennis V.
    CIRCULATION, 2007, 116 (16) : 567 - 567
  • [8] Late incomplete stent apposition after drug-eluting stent implantation: a true risk factor or "an innocent bystander"?
    Colombo, Antonio
    Latib, Azeem
    HEART, 2008, 94 (03) : 253 - 254
  • [9] Efficacy of Endeavor zotarolimus-eluting stent implantation for the treatment of very late stent thrombosis with late-acquired incomplete stent apposition after sirolimus-eluting stent implantation
    Kakefuda, Yuki
    Sato, Akira
    Watabe, Hiroaki
    Aihara, Hideaki
    Nishina, Hidetaka
    Noguchi, Yuichi
    Hoshi, Tomoya
    Aonuma, Kazutaka
    HEART AND VESSELS, 2016, 31 (07) : 1196 - 1199
  • [10] Efficacy of Endeavor zotarolimus-eluting stent implantation for the treatment of very late stent thrombosis with late-acquired incomplete stent apposition after sirolimus-eluting stent implantation
    Yuki Kakefuda
    Akira Sato
    Hiroaki Watabe
    Hideaki Aihara
    Hidetaka Nishina
    Yuichi Noguchi
    Tomoya Hoshi
    Kazutaka Aonuma
    Heart and Vessels, 2016, 31 : 1196 - 1199