Variation in tube voltage for pediatric neck 64VCT: Effect on radiation dose and image quality

被引:1
|
作者
Chen, Li-Guo [1 ]
Wu, Ping-An [1 ]
Tu, Hsing-Yang [1 ]
Sheu, Ming-Huei [1 ]
Huang, Li-Chuan [1 ,2 ]
机构
[1] Buddhist Tzu Chi Med Fdn, Hualien Tzu Chi Hosp, Dept Med Imaging, Hualien, Taiwan
[2] Tzu Chi Univ Sci & Technol, Dept Med Imaging & Radiol Sci, Hualien, Taiwan
来源
PLOS ONE | 2021年 / 16卷 / 11期
关键词
CT; PHANTOM; RECONSTRUCTION; REDUCTION; EXPOSURE;
D O I
10.1371/journal.pone.0259772
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Exposure to ionizing radiation can cause cancer, especially in children. In computed tomography (CT), a trade-off exists between the radiation dose and image quality. Few studies have investigated the effect of dose reduction on image quality in pediatric neck CT. We aimed to assess the effect of peak kilovoltage on the radiation dose and image quality in pediatric neck multidetector-row CT. Measurements were made using three phantoms representative of children aged 1, 5, and 10 years, with tube voltages of 80, 100, and 120 kilovoltage peak (kVp); tube current of 10, 40, 80, 120, 150, 200, and 250 mA; and exposure time = 0.5 s (pitch, 0.984:1). Radiation dose estimates were derived from the dose-length product with a 64-multidetector-row CT scanner. Images obtained from the control protocol (120 kVp) were compared with the 80- and 100-kVp protocols. The effective dose (ED) was determined for each protocol and compared with the 120-kVp protocol. Quantitative analysis entailed noise measurements by recording the standard deviation of attenuation for a circular 1-cm(2) region of interest placed on homogeneous soft tissue structures in the phantom. The mean noise of the various kVp protocols was compared using the unpaired Student t-test. Reduction of ED was 37.58% and 68.58% for neck CT with 100 kVp and 80 kVp, respectively. The image noise level increased with the decrease in peak kilovoltage. Noise values were higher at 80 kVp at all neck levels, but did not increase at 100 kVp, compared to 120 kVp in the three phantoms. The measured noise difference was the greatest at 80 kVp (absolute increases<2.5 HU). The subjective image quality did not differ among the protocols. Thus, reducing voltage from 120 to 80 kVp for neck CT may achieve ED reduction of 68.58%, without compromising image quality.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Radiation Dose Reduction at Pediatric CT: Use of Low Tube Voltage and Iterative Reconstruction
    Nagayama, Yasunori
    Oda, Seitaro
    Nakaura, Takeshi
    Tsuji, Akinori
    Urata, Joji
    Furusawa, Mitsuhiro
    Utsunomiya, Daisuke
    Funama, Yoshinori
    Kidoh, Masafumi
    Yamashita, Yasuyuki
    [J]. RADIOGRAPHICS, 2018, 38 (05) : 1421 - +
  • [32] Improvement of image quality and radiation dose of CT perfusion of the brain by means of low-tube voltage (70 KV)
    Li, Zhen-lin
    Li, Hang
    Zhang, Kai
    Li, Wang-jiang
    Chen, Xian
    Wu, Bin
    Song, Bin
    [J]. EUROPEAN RADIOLOGY, 2014, 24 (08) : 1906 - 1913
  • [33] Study of Image Quality, Radiation Dose and Low Contrast Resolution from MSCT Head by Using Low Tube Voltage
    Jumriah
    Dewang, Syamsir
    Abdullah, Bualkar
    Tahir, Dahlang
    [J]. 2ND INTERNATIONAL CONFERENCE ON SCIENCE (ICOS), 2018, 979
  • [34] Improvement of image quality and radiation dose of CT perfusion of the brain by means of low-tube voltage (70 KV)
    Zhen-lin Li
    Hang Li
    Kai Zhang
    Wang-jiang Li
    Xian Chen
    Bin Wu
    Bin Song
    [J]. European Radiology, 2014, 24 : 1906 - 1913
  • [35] Abdominal CT with low tube voltage: Preliminary observations about radiation dose, contrast enhancement, image quality, and noise
    Nakayama, Y
    Awai, K
    Funama, Y
    Hatemura, M
    Imuta, M
    Nakaura, T
    Ryu, D
    Morishita, S
    Sultana, S
    Sato, N
    Yamashita, Y
    [J]. RADIOLOGY, 2005, 237 (03) : 945 - 951
  • [36] Correlation between low tube voltage in dual source CT coronary artery imaging with image quality and radiation dose
    Zi-qiao Lei
    Ping Han
    Hai-bo Xu
    Jian-ming Yu
    Hong-li Liu
    [J]. Journal of Huazhong University of Science and Technology [Medical Sciences], 2014, 34 : 616 - 620
  • [37] Correlation between Low Tube Voltage in Dual Source CT Coronary Artery Imaging with Image Quality and Radiation Dose
    雷子乔
    韩萍
    徐海波
    余建明
    刘红利
    [J]. Journal of Huazhong University of Science and Technology(Medical Sciences), 2014, 34 (04) : 616 - 620
  • [38] Studies on the radiation dose, image quality and low contrast detectability from MSCT abdomen by using low tube voltage
    A. Mokhtar
    Z. A. Aabdelbary
    A. Sarhan
    H. M. Gad
    M. T. Ahmed
    [J]. Egyptian Journal of Radiology and Nuclear Medicine, 52
  • [39] Studies on the radiation dose, image quality and low contrast detectability from MSCT abdomen by using low tube voltage
    Mokhtar, A.
    Aabdelbary, Z. A.
    Sarhan, A.
    Gad, H. M.
    Ahmed, M. T.
    [J]. EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2021, 52 (01):
  • [40] Correlation between low tube voltage in dual source CT coronary artery imaging with image quality and radiation dose
    Lei, Zi-qiao
    Han, Ping
    Xu, Hai-bo
    Yu, Jian-ming
    Liu, Hong-li
    [J]. JOURNAL OF HUAZHONG UNIVERSITY OF SCIENCE AND TECHNOLOGY-MEDICAL SCIENCES, 2014, 34 (04) : 616 - 620