Interosseous ligament tears of the wrist: Comparison of multi-detector row CT arthrography and MR imaging

被引:76
|
作者
Schmid, MR
Schertler, T
Pfirrmann, CW
Saupe, N
Manestar, M
Wildermuth, S
Welshaupt, D
机构
[1] Balgrist Univ Hosp, Dept Radiol, CH-8008 Zurich, Switzerland
[2] Univ Zurich, Dept Diagnost Radiol, CH-8006 Zurich, Switzerland
[3] Univ Zurich, Dept Anat, CH-8006 Zurich, Switzerland
关键词
D O I
10.1148/radiol.2373041450
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare the accuracy of multi-detector row computed tomographic (CT) arthrography and magnetic resonance (MR) imaging in depicting tears of dorsal, central, and palmar segments of scapholunate (SL) and lunotriquetral (LT) ligaments in cadavers. MATERIALS AND METHODS: Cadaver wrists were obtained and used according to institutional guidelines and with informed consent of donors prior to death. Nine cadaver wrists of eight subjects were evaluated. MR images were obtained with a 1.5-T MR unit. Imaging protocol included intermediate-weighted coronal and transverse fast spin-echo and coronal three-dimensional gradient-echo sequences. Multidetector row CT arthrography was performed after tricompartmental injection of 3-6 mL of contrast material with a concentration of 160 mg per milliliter of iodine. Palmar, dorsal, and central segments of both ligaments were analyzed on transverse and coronal MR images and multiplanar multi-detector row CT reconstructions by two musculoskeletal radiologists working independently. Open inspection of the wrists was the reference standard. Sensitivity, specificity, accuracy, and positive and negative predictive values were calculated from the imaging and gross pathologic readings. Statistical significance was calculated with the McNemar test. Weighted K values for interobserver agreement were calculated for both imaging modalities. RESULTS: All ligament segments could be visualized in all cases with both imaging modalities. CT arthrography was more sensitive (100%) than MR imaging (60%) in detection of palmar segment tears (P =.62); specificity of both imaging modalities was 77%. Sensitivity (CT arthrography, 86%; MR imaging, 79%) and specificity (CT arthrography, 50%; MR imaging, 25%) for detection of the central segment tears were determined. Dorsal segment tears were detected only with CT arthrography, while all tears were missed with MR imaging (P =.02). Interobserver agreement was better for multi-detector row CT arthrography (K = 0.37-0.78) than for MR imaging (K = -0.33 to -0.10). CONCLUSION: Performance in depiction of palmar and central segment tears of SL and LT ligaments is almost equal for multi-detector row CT arthrography and MR imaging, with much higher interobserver reliability for CT arthrography. CT arthrography is significantly superior to MR imaging in the detection of dorsal segment tears of SL and LT ligaments. (c) RSNA, 2005.
引用
收藏
页码:1008 / 1013
页数:6
相关论文
共 50 条
  • [41] Acute aortic syndromes: Role of multi-detector row CT
    Salvolini, Luca
    Renda, Pietro
    Fiore, Davide
    Scaglione, Mariano
    Piccoli, GianPiero
    Giovagnoni, Andrea
    EUROPEAN JOURNAL OF RADIOLOGY, 2008, 65 (03) : 350 - 358
  • [42] Orthopedic hardware complications diagnosed with multi-detector row CT
    Ohashi, K
    El-Khoury, GY
    Bennett, DL
    Restrepo, JM
    Berbaum, KS
    RADIOLOGY, 2005, 237 (02) : 570 - 577
  • [43] Virtual endoscopy of dogs using multi-detector row CT
    Yamada, Kazutaka
    Morimoto, Manabu
    Kishimoto, Miori
    Wisner, Erik R.
    VETERINARY RADIOLOGY & ULTRASOUND, 2007, 48 (04) : 318 - 322
  • [44] Multi-detector row CT angiography in patients with abdominal angina
    Cademartiri, F
    Raaijmakers, RHJM
    Kuiper, JW
    van Dijk, LC
    Pattynama, PMT
    Krestin, GP
    RADIOGRAPHICS, 2004, 24 (04) : 969 - 984
  • [45] Multi-detector row CT of pancreatic islet cell tumors
    Horton, Karen M.
    Hruban, Ralph H.
    Yeo, Charles
    Fishman, Elliot K.
    RADIOGRAPHICS, 2006, 26 (02) : 453 - U10
  • [46] Multi-detector row CT: Principles and practice for abdominal applications
    Saini, S
    RADIOLOGY, 2004, 233 (02) : 323 - 327
  • [47] Application of multi-detector row helical scanning to postmyelographic CT
    Tsuchiya, K
    Katase, S
    Aoki, C
    Hachiya, J
    EUROPEAN RADIOLOGY, 2003, 13 (06) : 1438 - 1443
  • [48] Recent Technologic Advances in Multi-Detector Row Cardiac CT
    Halliburton, Sandra Simon
    CARDIOLOGY CLINICS, 2009, 27 (04) : 655 - +
  • [49] Comparison of MRI & direct MR arthrography with arthroscopy in diagnosing ligament injuries of wrist
    Cherian, Blessin S.
    Bhat, Anil K.
    Rajagopal, K., V
    Maddukuri, Satish B.
    Paul, Don
    Mathai, Naveen Joseph
    JOURNAL OF ORTHOPAEDICS, 2020, 19 : 203 - 207