Interosseous ligament tears of the wrist: Comparison of multi-detector row CT arthrography and MR imaging

被引:76
|
作者
Schmid, MR
Schertler, T
Pfirrmann, CW
Saupe, N
Manestar, M
Wildermuth, S
Welshaupt, D
机构
[1] Balgrist Univ Hosp, Dept Radiol, CH-8008 Zurich, Switzerland
[2] Univ Zurich, Dept Diagnost Radiol, CH-8006 Zurich, Switzerland
[3] Univ Zurich, Dept Anat, CH-8006 Zurich, Switzerland
关键词
D O I
10.1148/radiol.2373041450
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare the accuracy of multi-detector row computed tomographic (CT) arthrography and magnetic resonance (MR) imaging in depicting tears of dorsal, central, and palmar segments of scapholunate (SL) and lunotriquetral (LT) ligaments in cadavers. MATERIALS AND METHODS: Cadaver wrists were obtained and used according to institutional guidelines and with informed consent of donors prior to death. Nine cadaver wrists of eight subjects were evaluated. MR images were obtained with a 1.5-T MR unit. Imaging protocol included intermediate-weighted coronal and transverse fast spin-echo and coronal three-dimensional gradient-echo sequences. Multidetector row CT arthrography was performed after tricompartmental injection of 3-6 mL of contrast material with a concentration of 160 mg per milliliter of iodine. Palmar, dorsal, and central segments of both ligaments were analyzed on transverse and coronal MR images and multiplanar multi-detector row CT reconstructions by two musculoskeletal radiologists working independently. Open inspection of the wrists was the reference standard. Sensitivity, specificity, accuracy, and positive and negative predictive values were calculated from the imaging and gross pathologic readings. Statistical significance was calculated with the McNemar test. Weighted K values for interobserver agreement were calculated for both imaging modalities. RESULTS: All ligament segments could be visualized in all cases with both imaging modalities. CT arthrography was more sensitive (100%) than MR imaging (60%) in detection of palmar segment tears (P =.62); specificity of both imaging modalities was 77%. Sensitivity (CT arthrography, 86%; MR imaging, 79%) and specificity (CT arthrography, 50%; MR imaging, 25%) for detection of the central segment tears were determined. Dorsal segment tears were detected only with CT arthrography, while all tears were missed with MR imaging (P =.02). Interobserver agreement was better for multi-detector row CT arthrography (K = 0.37-0.78) than for MR imaging (K = -0.33 to -0.10). CONCLUSION: Performance in depiction of palmar and central segment tears of SL and LT ligaments is almost equal for multi-detector row CT arthrography and MR imaging, with much higher interobserver reliability for CT arthrography. CT arthrography is significantly superior to MR imaging in the detection of dorsal segment tears of SL and LT ligaments. (c) RSNA, 2005.
引用
收藏
页码:1008 / 1013
页数:6
相关论文
共 50 条
  • [21] Multi-detector row CT imaging of vertebral microstructure for evaluation of fracture risk
    Ito, M
    Ikeda, K
    Nishiguchi, M
    Shindo, H
    Uetani, M
    Hosoi, T
    Orimo, H
    JOURNAL OF BONE AND MINERAL RESEARCH, 2005, 20 (10) : 1828 - 1836
  • [22] Multi-detector row CT urography in the evaluation of hematuria
    Joffe, SA
    Servaes, S
    Okon, S
    Horowitz, M
    RADIOGRAPHICS, 2003, 23 (06) : 1441 - 1455
  • [23] Pancreas divisum: Depiction with multi-detector row CT
    Soto, JA
    Lucey, BC
    Stuhlfaut, JW
    RADIOLOGY, 2005, 235 (02) : 503 - 508
  • [24] Multi-detector row CT artifacts that mimic disease
    Cody, DD
    Stevens, DM
    Ginsberg, LE
    RADIOLOGY, 2005, 236 (03) : 756 - 761
  • [25] 64 Slice multi-detector row cardiac CT
    Pannu H.K.
    Johnson P.T.
    Fishman E.K.
    Emergency Radiology, 2009, 16 (1) : 1 - 10
  • [26] Short pancreas: evaluation with multi-detector row CT
    Acar, Murat
    Degirmenci, Bumin
    Tatli, Servet
    SURGICAL AND RADIOLOGIC ANATOMY, 2010, 32 (09) : 853 - 858
  • [27] Colonic distention in multi-detector row CT colonography
    Bruzzi, JF
    Fenlon, HM
    RADIOLOGY, 2004, 231 (01) : 282 - 282
  • [28] Multi-detector row CT: Radiation dose characteristics
    Hamberg, LM
    Rhea, JT
    Hunter, GJ
    Thrall, JH
    RADIOLOGY, 2003, 226 (03) : 762 - 772
  • [29] Short pancreas: evaluation with multi-detector row CT
    Murat Acar
    Bumin Degirmenci
    Servet Tatli
    Surgical and Radiologic Anatomy, 2010, 32 : 853 - 858
  • [30] Hepatic metastases: Detection with multi-detector row CT, SPIO-enhanced MR imaging, and both techniques combined
    Onishi, H
    Murakami, T
    Kim, T
    Hori, M
    Iannaccone, R
    Kuwabara, M
    Abe, H
    Nakata, S
    Osuga, K
    Tomoda, K
    Passariello, R
    Nakamura, H
    RADIOLOGY, 2006, 239 (01) : 131 - 138