Noncontact SpO2 Measurement Using Eulerian Video Magnification

被引:26
|
作者
Galvao Rosa, Alessandra de Fatima [1 ]
Betini, Roberto Cesar [1 ]
机构
[1] Fed Univ Thchnol Parana, Acad Dept Informat, BR-80230901 Curitiba, Parana, Brazil
关键词
Image photoplethysmography (iPPG); noncontact monitoring; peripheral oxygen saturation (SpO(2)); remote photoplethysmography (rPPG); OXYGEN-SATURATION; PULSE OXIMETRY; HEART-RATE; REFLECTANCE; CALIBRATION; LIGHT;
D O I
10.1109/TIM.2019.2920183
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Peripheral oxygen saturation (SpO(2)) monitoring is critical during surgery and in intensive care units (ICS). Over the last decades, several studies have addressed the noncontact monitoring of vital signs, but few reports have focused on SpO(2). This paper presents an SpO(2) monitoring method without physical contact with the patient using imaging photoplethysmography (iPPG). Eulerian video magnification (EVM) was employed in the proposed solution to amplify the changes in skin color due to the heart cycle. The developed software operates on a widely available, low-cost hardware platform. Experiments were performed with nine healthy individuals. When comparing the experimental SpO(2) results to those obtained with a reference pulse oximeter, the proposed solution showed good accuracy, with differences of less than 2%.
引用
收藏
页码:2120 / 2130
页数:11
相关论文
共 50 条
  • [41] Detection of Limb Ischemia Based on Eulerian Video Magnification
    Liu, Nenrong
    Wang, Jing
    Yuan, Hui
    Shi, Xiaowei
    Zhang, Xianzeng
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS VIII, 2018, 10820
  • [42] Eulerian Video Magnification for Revealing Subtle Changes in the World
    Wu, Hao-Yu
    Rubinstein, Michael
    Shih, Eugene
    Guttag, John
    Durand, Fredo
    Freeman, William
    ACM TRANSACTIONS ON GRAPHICS, 2012, 31 (04):
  • [43] A Patch-Type Wireless Forehead Pulse Oximeter for SpO2 Measurement
    Azhari, A.
    Yoshimoto, S.
    Nezu, T.
    Iida, H.
    Ota, H.
    Noda, Y.
    Araki, T.
    Uemura, T.
    Sekitani, T.
    Morii, K.
    2017 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2017,
  • [44] SpO2 Detecting Applied on Android Platform
    Hu, Zhongshun
    Li, Shuyu
    Li, Deyu
    SENSORS, MEASUREMENT AND INTELLIGENT MATERIALS, PTS 1-4, 2013, 303-306 : 659 - 662
  • [45] Contactless SpO2 Detection from Face Using Consumer Camera
    Zhu, Li
    Vatanparvar, Korosh
    Gwak, Migyeong
    Kuang, Jilong
    Gao, Alex
    2022 IEEE-EMBS INTERNATIONAL CONFERENCE ON BIOMEDICAL AND HEALTH INFORMATICS (BHI'22) JOINTLY ORGANISED WITH THE IEEE-EMBS INTERNATIONAL CONFERENCE ON WEARABLE AND IMPLANTABLE BODY SENSOR NETWORKS (BSN'22), 2022,
  • [46] A Deep Learning Approach for Estimating SpO2 Using a Smartphone Camera
    Lampier, Lucas C.
    Floriano, Alan
    Valadao, Carlos T.
    Silva, Leticia A.
    De O. Caldeira, Eliete M.
    Bastos-Filho, Teodiano F.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [47] Assessing Cardiovascular Comorbidities in Sleep Apnea Patients Using SpO2
    Deviaene, Margot
    Varon, Carolina
    Testelmans, Dries
    Buyse, Bertien
    Van Huffel, Sabine
    2017 COMPUTING IN CARDIOLOGY (CINC), 2017, 44
  • [48] Consideration of the Effect of Preference for Image Contents using Apparent SpO2
    Sato, Yudai
    Yang, Du
    Sawada, Daiki
    Horita, Yuukou
    2018 INTERNATIONAL WORKSHOP ON ADVANCED IMAGE TECHNOLOGY (IWAIT), 2018,
  • [49] The Development of a Measuring System for Intraoral SpO2
    Kashima, Yuki
    Onimaru, Minako
    Isogai, Ryosuke
    Kawai, Noboru
    Yoshida, Yoshifumi
    Maki, Koutaro
    SENSORS, 2024, 24 (02)
  • [50] THE OYGEN TISSUE SATURATION (SPO2) AUDIT
    Jones, M.
    PEDIATRIC RESEARCH, 2010, 68 : 239 - 239