Noncontact SpO2 Measurement Using Eulerian Video Magnification

被引:26
|
作者
Galvao Rosa, Alessandra de Fatima [1 ]
Betini, Roberto Cesar [1 ]
机构
[1] Fed Univ Thchnol Parana, Acad Dept Informat, BR-80230901 Curitiba, Parana, Brazil
关键词
Image photoplethysmography (iPPG); noncontact monitoring; peripheral oxygen saturation (SpO(2)); remote photoplethysmography (rPPG); OXYGEN-SATURATION; PULSE OXIMETRY; HEART-RATE; REFLECTANCE; CALIBRATION; LIGHT;
D O I
10.1109/TIM.2019.2920183
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Peripheral oxygen saturation (SpO(2)) monitoring is critical during surgery and in intensive care units (ICS). Over the last decades, several studies have addressed the noncontact monitoring of vital signs, but few reports have focused on SpO(2). This paper presents an SpO(2) monitoring method without physical contact with the patient using imaging photoplethysmography (iPPG). Eulerian video magnification (EVM) was employed in the proposed solution to amplify the changes in skin color due to the heart cycle. The developed software operates on a widely available, low-cost hardware platform. Experiments were performed with nine healthy individuals. When comparing the experimental SpO(2) results to those obtained with a reference pulse oximeter, the proposed solution showed good accuracy, with differences of less than 2%.
引用
收藏
页码:2120 / 2130
页数:11
相关论文
共 50 条
  • [31] USING RESPIRATORY EFFORT AND SPO2 TO DETECT RESPIRATORY EVENTS
    Coronel, C.
    Wiesmeyr, C.
    Garn, H.
    Kohn, B.
    Wimmer, M.
    Mandl, M.
    Glos, M.
    Penzel, T.
    Kloesch, G.
    Stefanic-Kejik, A.
    Ock, M. B.
    Kaniusas, E.
    Seidel, S.
    SLEEP MEDICINE, 2019, 64 : S126 - S127
  • [32] 全麻术后SpO2监测
    牛录美,郑广德,张达仁
    河北医学院学报, 1995, (02) : 76 - 77
  • [33] Optimization of Sleep Apnea Detection using SpO2 and ANN
    Mostafa, Sheikh Shanawaz
    Carvalho, Joao Paulo
    Morgado-Dias, Fernando
    Ravelo-Garcia, Antonio
    2017 XXVI INTERNATIONAL CONFERENCE ON INFORMATION, COMMUNICATION AND AUTOMATION TECHNOLOGIES (ICAT), 2017,
  • [34] The Effect of Improper Pulse Oximetry Sensor Placement on SpO2 Measurement Accuracy
    Campbell, S. E.
    Hyde, L.
    Chung, P. A.
    ONeil, M. P.
    Mannheimer, P. D.
    ANESTHESIA AND ANALGESIA, 2007, 105 : S100 - S101
  • [35] Predictive agreement between the fetal SpO2 and cardiotocogram and between the fetal SpO2 and fetal scalp pH
    Kuhnert, M
    LABOR AND DELIVERY, 1998, : 144 - 148
  • [36] Detection of Muscle Tension Dysphonia Using Eulerian Video Magnification: A Pilot Study
    Adleberg, Jason
    Ferster, Ashley P. O'Connell
    Benito, Daniel A.
    Sataloff, Robert T.
    JOURNAL OF VOICE, 2020, 34 (04) : 622 - 628
  • [37] Trial of Measurement of Sleep Apnea Syndrome with Sound Monitoring and SpO2 at home
    Nobuyuki, Ashida
    Yasuhiro, Nasu
    Taiki, Teshima
    Miyae, Yamakawa
    Kiyoko, Makimoto
    Terumasa, Higashi
    2009 11TH INTERNATIONAL CONFERENCE ON E-HEALTH NETWORKING, APPLICATIONS AND SERVICES (HEALTHCOM 2009), 2009, : 66 - +
  • [38] Motion resistance in peripheral oxygen saturation monitoring using Biolight Analog SpO2 compared to Masimo SpO2: a non-inferiority study
    Yang, Ting
    Liu, Yong
    Cai, Fenghua
    Li, Yong
    Mudabbar, Muhammad Saqib
    BMC ANESTHESIOLOGY, 2024, 24 (01):
  • [39] Interactive Evolutionary Parameter Optimization for Eulerian Video Magnification
    Rizvi, Syed Raazi
    Rahnamayan, Shahryar
    2018 IEEE SYMPOSIUM SERIES ON COMPUTATIONAL INTELLIGENCE (IEEE SSCI), 2018, : 10 - 16
  • [40] Towards an Implantable Telemetry System for SpO2 and PWV Measurement in Small Animals
    Schonle, Philipp
    Wang, Qing
    Brun, Noe
    Boser, Jonathan
    Meier, Pascale
    Huang, Qiuting
    2017 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2017,