Noncontact SpO2 Measurement Using Eulerian Video Magnification

被引:26
|
作者
Galvao Rosa, Alessandra de Fatima [1 ]
Betini, Roberto Cesar [1 ]
机构
[1] Fed Univ Thchnol Parana, Acad Dept Informat, BR-80230901 Curitiba, Parana, Brazil
关键词
Image photoplethysmography (iPPG); noncontact monitoring; peripheral oxygen saturation (SpO(2)); remote photoplethysmography (rPPG); OXYGEN-SATURATION; PULSE OXIMETRY; HEART-RATE; REFLECTANCE; CALIBRATION; LIGHT;
D O I
10.1109/TIM.2019.2920183
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Peripheral oxygen saturation (SpO(2)) monitoring is critical during surgery and in intensive care units (ICS). Over the last decades, several studies have addressed the noncontact monitoring of vital signs, but few reports have focused on SpO(2). This paper presents an SpO(2) monitoring method without physical contact with the patient using imaging photoplethysmography (iPPG). Eulerian video magnification (EVM) was employed in the proposed solution to amplify the changes in skin color due to the heart cycle. The developed software operates on a widely available, low-cost hardware platform. Experiments were performed with nine healthy individuals. When comparing the experimental SpO(2) results to those obtained with a reference pulse oximeter, the proposed solution showed good accuracy, with differences of less than 2%.
引用
收藏
页码:2120 / 2130
页数:11
相关论文
共 50 条
  • [1] A Non-Contact SpO2 estimation using a Video Magnification Technique
    Brieva, Jorge
    Moya-Albor, Ernesto
    Ponce, Hiram
    17TH INTERNATIONAL SYMPOSIUM ON MEDICAL INFORMATION PROCESSING AND ANALYSIS, 2021, 12088
  • [2] Wrist Pulse Measurement and Analysis using Eulerian Video Magnification
    He, Xiaochuan
    Goubran, Rafik A.
    Liu, Xiaoping P.
    2016 3RD IEEE EMBS INTERNATIONAL CONFERENCE ON BIOMEDICAL AND HEALTH INFORMATICS, 2016, : 41 - 44
  • [3] Accelerating Eulerian Video Magnification Using FPGA
    Zhang, Kening
    Jin, Xi
    Wu, An
    2017 19TH INTERNATIONAL CONFERENCE ON ADVANCED COMMUNICATIONS TECHNOLOGY (ICACT) - OPENING NEW ERA OF SMART SOCIETY, 2017, : 554 - 559
  • [4] A Multi-Channel Ratio-of-Ratios Method for Noncontact Hand Video Based SpO2 Monitoring Using Smartphone Cameras
    Tian, Xin
    Wong, Chau-Wai
    Ranadive, Sushant M.
    Wu, Min
    IEEE JOURNAL OF SELECTED TOPICS IN SIGNAL PROCESSING, 2022, 16 (02) : 197 - 207
  • [5] The wearable device for acute mountain sickness by using spo2 measurement
    Liu C.C.
    Huang S.
    Yang J.C.
    Lin T.-C.
    Huang L.-W.
    Kao B.H.
    Kuo C.W.
    Transactions of Japanese Society for Medical and Biological Engineering, 2018, 56 (Proc): : 49 - 50
  • [6] A study of the influence of video quality on Apparent SpO2
    Niigaki, Yota
    Du, Yang
    Sawada, Daiki
    Horita, Yuukou
    2018 INTERNATIONAL WORKSHOP ON ADVANCED IMAGE TECHNOLOGY (IWAIT), 2018,
  • [7] Using SpO2: Not as Simple as It Seems
    Hess, Dean R.
    RESPIRATORY CARE, 2023, 68 (05) : 708 - 711
  • [8] Eulerian Video Magnification and Analysis
    Wadhwa, Neal
    Wu, Hao-Yu
    Davis, Abe
    Rubinstein, Michael
    Shih, Eugene
    Mysore, Gautham J.
    Chen, Justin G.
    Buyukozturk, Oral
    Guttag, John V.
    Freeman, William T.
    Durand, Fredo
    COMMUNICATIONS OF THE ACM, 2017, 60 (01) : 87 - 95
  • [9] Enhanced Eulerian Video Magnification
    Liu, Le
    Lu, Le
    Luo, Jingjing
    Zhang, Jun
    Chen, Xiuhong
    2014 7TH INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING (CISP 2014), 2014, : 50 - 54
  • [10] Measurement of Arterial Oxygen Saturation (SpO2) using PPG Optical Sensor
    Mohan, P. Madhan
    Nisha, A. Annie
    Nagarajan, V.
    Jothi, E. Smiley Jeya
    2016 INTERNATIONAL CONFERENCE ON COMMUNICATION AND SIGNAL PROCESSING (ICCSP), VOL. 1, 2016, : 1136 - 1140