Ultra-high-resolution Mapping of Cortical Layers 3T-Guided 7T MRI

被引:2
|
作者
Ramadass, Karthik [1 ]
Rheault, Francois [3 ]
Cai, Leon Y. [2 ]
Remedios, Lucas W. [1 ]
DArchangel, Micah [5 ]
Lyu, Ilwoo [3 ,4 ]
Barquero, Laura A. [5 ]
Newton, Allen T. [2 ,6 ]
Cutting, Laurie E. [5 ]
Huo, Yuankai [1 ,3 ]
Landman, Bennett A. [1 ,2 ,3 ,5 ,6 ]
机构
[1] Vanderbilt Univ, Dept Comp Sci, Nashville, TN 37235 USA
[2] Vanderbilt Univ, Dept Biomed Engn, Nashville, TN 37235 USA
[3] Vanderbilt Univ, Dept Elect & Comp Engn, 221 Kirkland Hall, Nashville, TN 37235 USA
[4] Ulsan Natl Inst Sci & Technol, Dept Comp Sci & Engn, Ulsan, South Korea
[5] Vanderbilt Univ, Vanderbilt Brain Inst, 221 Kirkland Hall, Nashville, TN 37235 USA
[6] Vanderbilt Univ, Inst Imaging Sci, 221 Kirkland Hall, Nashville, TN 37235 USA
来源
基金
美国国家卫生研究院;
关键词
MRI; cortical surface mapping; T1-weighted; SWI;
D O I
10.1117/12.2611857
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
7T MRI provides unprecedented resolution for examining human brain anatomy in vivo. For example, 7T MRI enables deep thickness measurement of laminar subdivisions in the right fusiform area. Existing laminar thickness measurement on 7T is labor intensive, and error prone since the visual inspection of the image is typically along one of the three orthogonal planes (axial, coronal, or sagittal view). To overcome this, we propose a new analytics tool that allows flexible quantification of cortical thickness on a 2D plane that is orthogonal to the cortical surface (beyond axial, coronal, and sagittal views) based on the 3D computational surface reconstruction. The proposed method further distinguishes high quality 2D planes and the low-quality ones by automatically inspecting the angles between the surface normals and slice direction. In our approach, we acquired a pair of 3T and 7T scans (same subject). We extracted the brain surfaces from the 3T scan using MaCRUISE and projected the surface to the 7T scan's space. After computing the angles between the surface normals and axial direction vector, we found that 18.58% of surface points were angled at more than 80 degrees with the axial direction vector and had 2D axial planes with visually distinguishable cortical layers. 15.12% of the surface points with normal vectors angled at 30 degrees or lesser with the axial direction, had poor 2D axial slices for visual inspection of the cortical layers. This effort promises to dramatically extend the area of cortex that can be quantified with ultra-high resolution in-plane imaging methods.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Prospective motion correction improves high-resolution quantitative susceptibility mapping at 7T
    Mattern, Hendrik
    Sciarra, Alessandro
    Luesebrink, Falk
    Acosta-Cabronero, Julio
    Speck, Oliver
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (03) : 1605 - 1619
  • [42] High resolution single-shot EPI at 7T
    Oliver Speck
    J. Stadler
    M. Zaitsev
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2008, 21
  • [43] High resolution single-shot EPI at 7T
    Speck, Oliver
    Stadler, J.
    Zaitsev, M.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2008, 21 (1-2) : 73 - 86
  • [44] Ultra-High Field 7T MRI: A New Tool for Studying Alzheimer's Disease
    Kerchner, Geoffrey A.
    JOURNAL OF ALZHEIMERS DISEASE, 2011, 26 : 91 - 95
  • [45] Widespread inflammation in CLIPPERS syndrome indicated by autopsy and ultra-high-field 7T MRI
    Blaabjerg, Morten
    Ruprecht, Klemens
    Sinnecker, Tim
    Kondziella, Daniel
    Niendorf, Thoralf
    Kerrn-Jespersen, Bjorg Morell
    Lindelof, Mette
    Lassmann, Hans
    Kristensen, Bjarne Winther
    Paul, Friedemann
    Illes, Zsolt
    NEUROLOGY-NEUROIMMUNOLOGY & NEUROINFLAMMATION, 2016, 3 (03):
  • [46] Ultra-High 7T MRI of Structural Age-Related Changes of the Subthalamic Nucleus
    Keuken, Max C.
    Bazin, Pierre-Louis
    Schaefer, Andreas
    Neumann, Jane
    Turner, Robert
    Forstmann, Birte U.
    JOURNAL OF NEUROSCIENCE, 2013, 33 (11): : 4896 - 4900
  • [47] Ultra High Field 7T MR Carotid Vessel Wall Imaging: Comparison with 3T
    Kroner, Eleanore S.
    Versluis, Maarten
    van der Wall, Ernst
    de Roos, Albert
    Webb, Andrew
    Siebelink, Hans-Marc
    Lamb, Hildo
    CIRCULATION, 2012, 126 (21)
  • [48] How to Implement Clinical 7T MRI-Practical Considerations and Experience with Ultra-High-Field MRI
    Cramer, Justin
    Ikuta, Ichiro
    Zhou, Yuxiang
    BIOENGINEERING-BASEL, 2024, 11 (12):
  • [49] Mapping of the internal structure of human habenula with ex vivo MRI at 7T
    Strotmann, Barbara
    Koegler, Carsten
    Bazin, Pierre-Louis
    Weiss, Marcel
    Villringer, Arno
    Turner, Robert
    FRONTIERS IN HUMAN NEUROSCIENCE, 2013, 7
  • [50] Selective activation of mesoscale functional circuits via multichannel infrared stimulation of cortical columns in ultra-high-field 7T MRI
    Tian, Feiyan
    Liu, Yipeng
    Chen, Meixuan
    Schriver, Kenneth Edward
    Roe, Anna Wang
    CELL REPORTS METHODS, 2025, 5 (01):