Ultra-high-resolution Mapping of Cortical Layers 3T-Guided 7T MRI

被引:2
|
作者
Ramadass, Karthik [1 ]
Rheault, Francois [3 ]
Cai, Leon Y. [2 ]
Remedios, Lucas W. [1 ]
DArchangel, Micah [5 ]
Lyu, Ilwoo [3 ,4 ]
Barquero, Laura A. [5 ]
Newton, Allen T. [2 ,6 ]
Cutting, Laurie E. [5 ]
Huo, Yuankai [1 ,3 ]
Landman, Bennett A. [1 ,2 ,3 ,5 ,6 ]
机构
[1] Vanderbilt Univ, Dept Comp Sci, Nashville, TN 37235 USA
[2] Vanderbilt Univ, Dept Biomed Engn, Nashville, TN 37235 USA
[3] Vanderbilt Univ, Dept Elect & Comp Engn, 221 Kirkland Hall, Nashville, TN 37235 USA
[4] Ulsan Natl Inst Sci & Technol, Dept Comp Sci & Engn, Ulsan, South Korea
[5] Vanderbilt Univ, Vanderbilt Brain Inst, 221 Kirkland Hall, Nashville, TN 37235 USA
[6] Vanderbilt Univ, Inst Imaging Sci, 221 Kirkland Hall, Nashville, TN 37235 USA
来源
基金
美国国家卫生研究院;
关键词
MRI; cortical surface mapping; T1-weighted; SWI;
D O I
10.1117/12.2611857
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
7T MRI provides unprecedented resolution for examining human brain anatomy in vivo. For example, 7T MRI enables deep thickness measurement of laminar subdivisions in the right fusiform area. Existing laminar thickness measurement on 7T is labor intensive, and error prone since the visual inspection of the image is typically along one of the three orthogonal planes (axial, coronal, or sagittal view). To overcome this, we propose a new analytics tool that allows flexible quantification of cortical thickness on a 2D plane that is orthogonal to the cortical surface (beyond axial, coronal, and sagittal views) based on the 3D computational surface reconstruction. The proposed method further distinguishes high quality 2D planes and the low-quality ones by automatically inspecting the angles between the surface normals and slice direction. In our approach, we acquired a pair of 3T and 7T scans (same subject). We extracted the brain surfaces from the 3T scan using MaCRUISE and projected the surface to the 7T scan's space. After computing the angles between the surface normals and axial direction vector, we found that 18.58% of surface points were angled at more than 80 degrees with the axial direction vector and had 2D axial planes with visually distinguishable cortical layers. 15.12% of the surface points with normal vectors angled at 30 degrees or lesser with the axial direction, had poor 2D axial slices for visual inspection of the cortical layers. This effort promises to dramatically extend the area of cortex that can be quantified with ultra-high resolution in-plane imaging methods.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Segmentation of supragranular and infragranular layers in ultra-high-resolution 7T ex vivo MRI of the human cerebral cortex
    Zeng, Xiangrui
    Puonti, Oula
    Sayeed, Areej
    Herisse, Rogeny
    Mora, Jocelyn
    Evancic, Kathryn
    Varadarajan, Divya
    Balbastre, Yael
    Costantini, Irene
    Scardigli, Marina
    Ramazzotti, Josephine
    DiMeo, Danila
    Mazzamuto, Giacomo
    Pesce, Luca
    Brady, Niamh
    Cheli, Franco
    Saverio Pavone, Francesco
    Hof, Patrick R.
    Frost, Robert
    Augustinack, Jean
    van der Kouwe, Andre
    Iglesias, Juan Eugenio
    Fischl, Bruce
    CEREBRAL CORTEX, 2024, 34 (09)
  • [2] Assessment of perilesional pathology in cortical and leukocortical lesions in MS by ultra high resolution quantitative 7T MRI
    Louapre, C.
    Govindaraja, S. T.
    Gianni, C.
    Sloane, J. A.
    Kinkel, R. P.
    Mainero, C.
    MULTIPLE SCLEROSIS JOURNAL, 2015, 21 : 13 - 13
  • [3] In vivo detection of cerebral cortical microinfarcts with high-resolution 7T MRI
    van Veluw, Susanne J.
    Zwanenburg, Jaco J. M.
    Engelen-Lee, JooYeon
    Spliet, Wim G. M.
    Hendrikse, Jeroen
    Luijten, Peter R.
    Biessels, Geert Jan
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2013, 33 (03): : 322 - 329
  • [4] Quantitative Susceptibility Mapping: MRI at 7T versus 3T
    Spincemaille, Pascal
    Anderson, Julie
    Wu, Gaohong
    Yang, Baolian
    Fung, Maggie
    Li, Ke
    Li, Shaojun
    Kovanlikaya, Ilhami
    Gupta, Ajay
    Kelley, Douglas
    Benhamo, Nissim
    Wang, Yi
    JOURNAL OF NEUROIMAGING, 2020, 30 (01) : 65 - 75
  • [5] HIGH RESOLUTION T1ρ MAPPING OF HUMAN KNEE CARTILAGE AT 7T
    Singh, A.
    Haris, M.
    Cai, K.
    Kogan, F.
    Hendler, B.
    Nanga, R. P.
    Witschey, W. R.
    Borthakur, A.
    Hariharan, H.
    Reddy, R.
    OSTEOARTHRITIS AND CARTILAGE, 2013, 21 : S200 - S201
  • [6] Ultra high spatial and temporal resolution breast imaging at 7T
    van de Bank, B. L.
    Voogt, I. J.
    Italiaander, M.
    Stehouwer, B. L.
    Boer, V. O.
    Luijten, P. R.
    Klomp, D. W. J.
    NMR IN BIOMEDICINE, 2013, 26 (04) : 367 - 375
  • [7] Hippocampal Sulcus Remnant: Common Finding in Nonelderly Adults on Ultra-High-Resolution 7T Magnetic Resonance Imaging
    Yamashita, Koji
    Zong, Xiaopeng
    Hung, Sheng-Che
    Lin, Weili
    Castillo, Mauricio
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2020, 44 (01) : 43 - 46
  • [8] High-Resolution 7T MRI of the Human Hippocampus In Vivo
    Thomas, Bradley P.
    Welch, E. Brian
    Niederhauser, Blake D.
    Whetsell, William O., Jr.
    Anderson, Adam W.
    Gore, John C.
    Avison, Malcolm J.
    Creasy, Jeffrey L.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 28 (05) : 1266 - 1272
  • [9] Cortical Localization of Microbleeds in Cerebral Amyloid Angiopathy: An Ultra High-Field 7T MRI Study
    Ni, Jun
    Auriel, Eithan
    Martinez-Ramirez, Sergi
    Keil, Boris
    Reed, Anne K.
    Fotiadis, Panagiotis
    Gurol, Edip Mahmut
    Greenberg, Steven M.
    Viswanathan, Anand
    JOURNAL OF ALZHEIMERS DISEASE, 2015, 43 (04) : 1325 - 1330
  • [10] High-Resolution Diffusion MRI Of The Trigeminal Nerve Using 7T MRI
    Lenglet, Christophe
    Sein, Julien
    Tokarev, Julian
    Grande, Andrew
    Jagadeesan, Bharathi
    van de Moortele, Pierre-Francois
    JOURNAL OF NEUROSURGERY, 2013, 119 (02) : A566 - A566