Average glandular dose with sectra MDM in routine mammography screening

被引:0
|
作者
Hemdal, B
Hermsdorf, L
Martin, M
Andersson, I
Bengtsson, G
Heddson, B
Olsson, M
机构
[1] Malmo Univ Hosp, Malmo, Sweden
[2] RTI Elect AB, Gothenburg, Sweden
[3] Therapy Phys Inc, Bellflower, CA USA
[4] Univ Lund Hosp, S-22185 Lund, Sweden
[5] Hosp Helsingborg, Helsingborg, Sweden
关键词
D O I
10.1118/1.1997516
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of this work was to implement different International protocols to estimate average glandular dose levels for the first Sectra MicroDose Mammography (MDM) unit used in routine mammography screening (Helsingborg, Sweden). Method and Materials: The Sectra MDM is a scanning multislit digital mammography system which uses a direct photon counting technique with a solid‐state detector, Si(B). A substantial dose reduction can be expected due to high photon absorption in the detector (90%) and scatter rejection (97%) as well as improved energy weighting compared to other mammography systems on the market. The multislit pre‐collimator scans with a distance of only 115 mm above the breast support making it impossible to follow the usual procedure for half value layer (HVL) measurement. Instead, a sensitive and well‐collimated solid state detector with simultaneous correction for the energy dependence (Barracuda X‐ray multimeter, RTI Electronics AB, Sweden) is used for non‐invasive measurements of the HVL. Results: The average glandular dose was found to be e.g. 0.28 mGy for a 50 mm standard breast with 50 % glandularity simulated with 45 mm PMMA according to the so‐called European protocol from 1996. Conclusion: Methods of how to perform absorbed dose measurements according to European and American protocols on the Sectra MDM have been developed. The average glandular dose is much lower than for any other mammography unit on the market today. However, for increased accuracy, the dose protocols should be revised to account for the anode/filter combination used with the Sectra unit (W/Al), the scattered radiation from the multislit pre‐collimator device and the occurrence of a dose profile in the scanning direction. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:1912 / 1912
页数:1
相关论文
共 50 条
  • [1] Average glandular dose in routine mammography screening using a Sectra MicroDose Mammography unit
    Hemdal, B
    Herrnsdorf, L
    Andersson, I
    Bengtsson, G
    Heddson, B
    Olsson, M
    [J]. RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) : 436 - 443
  • [2] Digital mammography screening: Average glandular dose and first performance parameters
    Weigel, S.
    Girnus, R.
    Czwoydzinski, J.
    Decker, T.
    Spital, S.
    Heindel, W.
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2007, 179 (09): : 892 - 895
  • [3] Patient Specific Average Glandular Dose in Mammography
    Patel, V.
    Highnam, R.
    Tromans, C.
    Pizzutiello, R. J.
    Destounis, S.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [4] NORMALIZED AVERAGE GLANDULAR DOSE IN MAGNIFICATION MAMMOGRAPHY
    LIU, B
    GOODSITT, M
    CHAN, HP
    [J]. RADIOLOGY, 1995, 197 (01) : 27 - 32
  • [5] Method for the evaluation of a average glandular dose in mammography
    Okunade, AA
    [J]. MEDICAL PHYSICS, 2006, 33 (04) : 1153 - 1164
  • [6] Can the average glandular dose in routine digital mammography screening be reduced?: A pilot study using revised image quality criteria
    Heindal, B
    Andersson, I
    Grahn, A
    Håkansson, M
    Ruschin, M
    Thilander-Klang, A
    Båth, M
    Börjesson, S
    Medin, J
    Tingberg, A
    Månsson, LG
    Mattsson, S
    [J]. RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) : 383 - 388
  • [7] New Way for Calculating the Average Glandular Dose in the Mammography
    Penchev, P.
    Schopphoven, S.
    Smirnov, A.
    Bock, K.
    Fiebich, M.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [8] Parametrization of mammography normalized average glandular dose tables
    Sobol, WT
    Wu, XZ
    [J]. MEDICAL PHYSICS, 1997, 24 (04) : 547 - 554
  • [9] Average Glandular Dose in Digital Mammography and Breast Tomosynthesis
    Olgar, T.
    Kahn, T.
    Gosch, D.
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2012, 184 (10): : 911 - 918
  • [10] Average glandular dose and phantom image quality in mammography
    Oliveira, M.
    Noguelra, M. S.
    Guedes, E.
    Andrade, M. C.
    Peixoto, J. E.
    Joana, G. S.
    Castro, J. G.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01): : 574 - 577