Optimal Number and Location of Power Quality Monitors for Power System

被引:0
|
作者
Li Hui [1 ]
机构
[1] Naval Univ Engn, Dept Elect Engn, Wuhan, Peoples R China
关键词
power quality monitoring; multi-objective evolutionary problem; genetic algorithm; pareto optimal solutions; radar chart;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
this work presents a method for solving optimal number and location of power quality monitors in transmission power systems. The problem is modeled as a multi -objective problem to acquire a tradeoff between the data redundancy and the economical efficiency. A multi-objective optimal placement model is built, in which the monitoring locations and the number of monitors are taken as objects. Adaptive genetic algorithm is used to solve the formulated optimal model problem. The evolution attenuator factor is introduced into the genetic algorithm, which enables the new adaptive genetic algorithm to adjust the possibilities of crossover and mutation adaptively according to both the individual fitness and evolution generations. The objective functions in Pareto optimal solution set are analyzed and the scheme corresponding to the maximum value is chosen as the appropriate optimal solution. Through the simulation of an IEEE 30-bus system, a reasonable scheme for the placement of power quality monitors is obtained; meanwhile the feasibility and effectiveness of the proposed method are verified.
引用
收藏
页码:1650 / 1654
页数:5
相关论文
共 50 条
  • [21] Optimal Location of SMES for Improving Power System Voltage Stability
    Huang, Xiaohua
    Zhang, Guomin
    Xiao, Liye
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2010, 20 (03) : 1312 - 1315
  • [22] Optimal location of PWM based series compensator in a power system
    Safari, A.
    Shayanfar, H. A.
    Kazemi, A.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2013, 51 : 127 - 133
  • [23] Optimal Location of Distribution Generation Source in Power System Network
    Shrivastava, Vivek Kumar
    Rahi, O. P.
    Gupta, Vaibhav Kumar
    Singh, Sameer Kumar
    2012 IEEE FIFTH POWER INDIA CONFERENCE, 2012,
  • [24] Optimal Location of Variable Impedance Device for Power System Oscillations
    Mustafa, N. Magaji M. W.
    Muda, Z. Bint
    2010 2ND INTERNATIONAL CONFERENCE ON COMPUTER AND AUTOMATION ENGINEERING (ICCAE 2010), VOL 5, 2010, : 97 - 101
  • [25] Allocation of Power Quality Monitors by Clonal Algorithm
    Teixeira Martins, Paulo Estevao
    Zvietcovich, Wilingthon Guerra
    de Oliveira Silva, Thiago Augusto
    de Jesus Junior, Belmir Jose
    PROCEEDINGS OF 2016 17TH INTERNATIONAL CONFERENCE ON HARMONICS AND QUALITY OF POWER (ICHQP), 2016, : 980 - 985
  • [26] Transmission Systems Power Quality Monitors Allocation
    Reis, D. C. S.
    Villela, P. R. C.
    Duque, C. A.
    Ribeiro, P. F.
    2008 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-11, 2008, : 4661 - +
  • [27] New portable analyzer monitors power quality
    不详
    HYDROCARBON PROCESSING, 1999, 78 (01): : 38 - 38
  • [28] Optimal location of UPQC for power quality improvement: novel hybrid approach
    Gaddala, Kaladhar
    Raju, P. Sangameswara
    JOURNAL OF ENGINEERING DESIGN AND TECHNOLOGY, 2020, 18 (06) : 1519 - 1541
  • [29] Optimal location of interline power flow controller in a power system network using ABC algorithm
    Sreejith, S.
    Psimon, Sishaj
    Selvan, M. P.
    ARCHIVES OF ELECTRICAL ENGINEERING, 2013, 62 (01) : 91 - 110
  • [30] Real-time monitoring and analysis system monitors industrial power quality
    Kubis, M
    Choo, CS
    CONTROL SOLUTIONS, 2003, 76 (03): : 17 - 18