Optimal Number and Location of Power Quality Monitors for Power System

被引:0
|
作者
Li Hui [1 ]
机构
[1] Naval Univ Engn, Dept Elect Engn, Wuhan, Peoples R China
关键词
power quality monitoring; multi-objective evolutionary problem; genetic algorithm; pareto optimal solutions; radar chart;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
this work presents a method for solving optimal number and location of power quality monitors in transmission power systems. The problem is modeled as a multi -objective problem to acquire a tradeoff between the data redundancy and the economical efficiency. A multi-objective optimal placement model is built, in which the monitoring locations and the number of monitors are taken as objects. Adaptive genetic algorithm is used to solve the formulated optimal model problem. The evolution attenuator factor is introduced into the genetic algorithm, which enables the new adaptive genetic algorithm to adjust the possibilities of crossover and mutation adaptively according to both the individual fitness and evolution generations. The objective functions in Pareto optimal solution set are analyzed and the scheme corresponding to the maximum value is chosen as the appropriate optimal solution. Through the simulation of an IEEE 30-bus system, a reasonable scheme for the placement of power quality monitors is obtained; meanwhile the feasibility and effectiveness of the proposed method are verified.
引用
收藏
页码:1650 / 1654
页数:5
相关论文
共 50 条
  • [1] Optimum number and location of power quality monitors
    Eldery, MA
    El-Saadany, EF
    Salama, MMA
    2004 11TH INTERNATIONAL CONFERENCE ON HARMONICS AND QUALITY OF POWER, 2004, : 50 - 57
  • [2] Optimal Number and Locations of Power Quality Monitors Considering System Topology
    Won, Dong-Jun
    Moon, Seung-Il
    2008 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-11, 2008, : 2586 - 2586
  • [3] Optimal number and locations of power quality monitors considering system topology
    Won, Dong-Jun
    Moon, Seung-Il
    IEEE TRANSACTIONS ON POWER DELIVERY, 2008, 23 (01) : 288 - 295
  • [4] Optimal location of Power Quality Monitors in distribution grids based on MRA methodology
    Ferreira V.
    Cerveira A.
    Baptista J.
    Renewable Energy and Power Quality Journal, 2022, 20 : 24 - 29
  • [5] Automatic Subtransmission Fault Location System using Power Quality Monitors
    Sabin, Daniel D.
    Dettloff, Andrew R.
    Golden, Paul
    2016 IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION (T&D), 2016,
  • [6] Optimal Location of Unified Power Quality Conditioner in Distribution System for Power Quality Improvement
    Sarker, Jayanti
    Goswami, S. K.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2016, 83 : 309 - 324
  • [7] Overview of an Automatic Distribution Fault Location System using Power Quality Monitors
    Sabin, Daniel D.
    Olechiw, Wieslaw Jerry
    Romero, Elder
    Manning, Robert
    Waclawiak, Marek
    2014 IEEE 16TH INTERNATIONAL CONFERENCE ON HARMONICS AND QUALITY OF POWER (ICHQP), 2014, : 502 - 506
  • [8] Redundancy-based approach for optimal number and location of power quality monitors in distribution systems with binary imperialist competitive approach
    Mohammadi, Mohammad
    AUTOMATIKA, 2022, 63 (01) : 132 - 148
  • [9] Optimal placement of power quality monitors by accounting for several key power quality disturbances
    Bosovic, Adnan
    Renner, Herwig
    Friedl, Herwig
    Abart, Andreas
    Traxler, Ewald
    Music, Mustafa
    ELECTRICAL ENGINEERING, 2024, 106 (03) : 2877 - 2892
  • [10] Optimized Allocation of Power Quality Monitors in Distribution Systems Considering Fault Location
    Teixeira Martins, Paulo Estevao
    Oleskovicz, Mario
    da Silva Pessoa, Andre Luis
    Faria, Iago de Moura
    2018 18TH INTERNATIONAL CONFERENCE ON HARMONICS AND QUALITY OF POWER (ICHQP), 2018,