Thermal helium desorption spectrometry of helium-implanted iron

被引:21
|
作者
Xu, Donghua [1 ]
Bus, Tjacka [1 ]
Glade, Stephen C. [1 ]
Wirth, Brian D. [1 ]
机构
[1] Univ Calif Berkeley, Dept Nucl Engn, Berkeley, CA 94720 USA
关键词
D O I
10.1016/j.jnucmat.2007.03.112
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Thermal helium desorption spectrometry (THDS) is employed to study the kinetics and energetics of helium in iron implanted with 100 keV He to 1 x 10(11), 1 x 10(13), and 1 x 10(15) He/cm(2). While no clear desorption signals are observed for the two lower dose samples, preliminary results reveal that the majority of the He atoms desorb at similar to 1000 degrees C and at > 1100 degrees C for the 1 x 10(15) He/cm(2) sample. Both conventional reaction model and Johnson-Mehl-Avrami (JMA) transformation model are utilized to analyze the similar to 1000 degrees C desorption event. The measured signal can be reproduced very well by combining a first-order and a higher order (n similar to 5.8) JMA fits. This event is observed repetitively during successive heating-cooling cycles. The success of the higher order JMA model and the repetitive appearance strongly suggest that this event is mainly associated with a <-> 7 phase transformation, while the dissociation of HeV clusters may also be involved. The observation of spurious peaks which may affect future studies is also reported. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:483 / 488
页数:6
相关论文
共 50 条
  • [21] Mechanical properties and microstructure of helium-implanted beryllium
    Kesternich, W
    Ullmaier, H
    JOURNAL OF NUCLEAR MATERIALS, 2003, 312 (2-3) : 212 - 223
  • [22] Helium bubble formation in YAG laser weldment of helium-implanted stainless steel
    Kuroda, T
    VACUUM, 2000, 59 (01) : 301 - 312
  • [23] About extended defect formation in helium-implanted germanium
    Rousselet, S.
    Declemy, A.
    Beaufort, M. -F.
    David, M. -L.
    Barbot, J. -F.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2012, 272 : 309 - 312
  • [24] Trapping of hydrogen impurities in helium-implanted niobium and tantalum
    1600, American Inst of Physics, Woodbury, NY, USA (75):
  • [25] MICROSTRUCTURE OF HELIUM-IMPLANTED NIMONIC PE16
    CZYRSKAFILEMONOWICZ, A
    GADALLA, AA
    WECKERMANN, B
    KESTERNICH, W
    JOURNAL OF NUCLEAR MATERIALS, 1987, 150 (01) : 24 - 30
  • [26] Cavity formation in helium-implanted silicon - Temperature dependence
    Barbot, JF
    Oliviero, E
    David, ML
    Rousselet, S
    Beaufort, MF
    van Veen, A
    DEFECTS AND DIFFUSION IN SEMICONDUCTORS, 2002, 210-2 : 37 - 42
  • [27] THERMAL-DESORPTION OF HELIUM FROM HOMOGENEOUSLY IMPLANTED GRAPHITE
    JUNG, P
    SCHROEDER, H
    JOURNAL OF NUCLEAR MATERIALS, 1991, 185 (02) : 149 - 153
  • [28] THERMAL HELIUM DESORPTION SPECTROMETRY ON PLASTICALLY DEFORMED MOLYBDENUM
    BUTERS, WTM
    VANDENBEUKEL, A
    JOURNAL OF NUCLEAR MATERIALS, 1985, 137 (01) : 57 - 62
  • [29] Helium retention and early stages of helium-vacancy complexes formation in low energy helium-implanted tungsten
    Lhuillier, P. E.
    Belhabib, T.
    Desgardin, P.
    Courtois, B.
    Sauvage, T.
    Barthe, M. F.
    Thomann, A. L.
    Brault, P.
    Tessier, Y.
    JOURNAL OF NUCLEAR MATERIALS, 2013, 433 (1-3) : 305 - 313
  • [30] Preservation dose of helium-implanted in nanocrystal titanium films
    Zheng, SX
    Luo, SZ
    Liu, ZY
    Long, XG
    Wang, PL
    Peng, SM
    Liao, XD
    Liu, N
    ACTA PHYSICA SINICA, 2004, 53 (02) : 555 - 560