Direct Electrochemistry of Hemoglobin Immobilized on Hydrophilic Ionic Liquid-chiitosan-ZrO2 Nanoparticles Composite Film with Carbon Ionic Liquid Electrode as the Platform

被引:4
|
作者
Qiao, Lifang [1 ]
Gao, Ruifang [1 ]
Zheng, Jianbin [1 ]
机构
[1] NW Univ Xian, Inst Analyt Sci, Shaanxi Prov Key Lab Electroanalyt Chem, Xian 710069, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
PYROLYTIC-GRAPHITE ELECTRODES; HYDROGEN-PEROXIDE BIOSENSOR; BIOMEMBRANE-LIKE FILMS; LAYER-BY-LAYER; HORSERADISH-PEROXIDASE; CYTOCHROME-C; AMPEROMETRIC BIOSENSOR; SILICA NANOCOMPOSITE; TRICHLOROACETIC-ACID; GOLD NANOPARTICLE;
D O I
10.2116/analsci.26.1181
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A stable composite film composed of 1-butyl-3-methyl-imidazolium tetrafluoroborate, chitosan, zirconia nanoparticles and the hemoglobin (Hb) was cast on the surface of an ionic liquid of an N-butylpyridinium hexafluorophosphate modified carbon paste electrode to fabricate a modified electrode. Scanning electron microscopy images of the modified electrode indicated that there was a dendritic structure on the modified electrode, and UV-Vis and FT-IR spectra showed that Hb in the composite film retained its native structure. Voltammetric experiments at the modified electrode showed that, in a pH 7.0 phosphate buffer solution, a pair of well-defined and quasi-reversible redox voltammetric peaks was obtained with the formal potential located at 0.216 V. The electrochemical parameters of Hb in the composite film were further carefully calculated: the electron-transfer rate constant was 0.52 s(-1) and the charge transfer coefficient was 0.34. The catalytic reduction peak current had a linear relationship with the concentration of trichloroacetic acid (TCA) in the range from 0.2 to 10.3 mmol/L with a detection limit of 66.7 mu mol/L. Therefore, the composite film as a novel matrix opened up a possibility for further study on the design of enzymatic biosensors with potential applications.
引用
收藏
页码:1181 / 1186
页数:6
相关论文
共 50 条
  • [31] Direct electrochemistry of myoglobin based on electrodeposition of Pd nanoparticles with carbon ionic liquid electrode as basic electrode
    Jinmei Huang
    Jianbin Zheng
    Qinglin Sheng
    Microchimica Acta, 2011, 173 : 157 - 163
  • [32] Direct electrochemistry of hemoglobin and its electrocatalytic effect based on its direct immobilization on carbon ionic liquid electrode
    Safavi, Afsaneh
    Maleki, Norouz
    Moradlou, Omran
    Sorouri, Mohsen
    ELECTROCHEMISTRY COMMUNICATIONS, 2008, 10 (03) : 420 - 423
  • [33] Direct electrochemistry and electrocatalysis of hemoglobin in composite film based on ionic liquid and NiO microspheres with different morphologies
    Dong, Sheying
    Zhang, Penghui
    Liu, Hui
    Li, Nan
    Huang, Tinglin
    BIOSENSORS & BIOELECTRONICS, 2011, 26 (10): : 4082 - 4087
  • [34] Application of N-doped graphene modified carbon ionic liquid electrode for direct electrochemistry of hemoglobin
    Sun, Wei
    Dong, Lifeng
    Deng, Ying
    Yu, Jianhua
    Wang, Wencheng
    Zhu, Qianqian
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2014, 39 : 86 - 91
  • [35] Direct electrochemistry of hemoglobin based on chitosan-ionic liquid-ferrocene/graphene composite film
    Huang, Ke-Jing
    Miao, Yong-Xia
    Wang, Lan
    Gan, Tian
    Yu, Meng
    Wang, Ling-Ling
    PROCESS BIOCHEMISTRY, 2012, 47 (07) : 1171 - 1177
  • [36] Application of NiMoO4 Nanorods for the Direct Electrochemistry and Electrocatalysis of Hemoglobin with Carbon Ionic Liquid Electrode
    Hu, Song
    Cao, Lili
    Sun, Zhaolan
    Xiang, Jun
    Lu, Ming
    Sun, Wei
    ELECTROANALYSIS, 2012, 24 (02) : 278 - 285
  • [37] Direct electrochemistry and electrocatalysis of hemoglobin on three-dimensional graphene modified carbon ionic liquid electrode
    Sun, Wei
    Hou, Fei
    Gong, Shixing
    Han, Lin
    Wang, Wencheng
    Shi, Fan
    Xi, Jingwen
    Wang, Xiuli
    Li, Guangjiu
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 219 : 331 - 337
  • [38] Direct electrochemistry and electrocatalysis of hemoglobin immobilized into poly (lactic-co-glycolic acid)/room temperature ionic liquid composite film
    Zhang, Yao
    Sun, Xiumei
    Jia, Nengqin
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 157 (02): : 527 - 532
  • [39] Direct electrochemistry and electrocatalytic properties of hemoglobin immobilized on a carbon ionic liquid electrode modified with mesoporous molecular sieve MCM-41
    Li, Yonghong
    Zeng, Xiandong
    Liu, Xiaoying
    Liu, Xinsheng
    Wei, Wanzhi
    Luo, Shenglian
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2010, 79 (01) : 241 - 245
  • [40] Electrocatalysis of Hemoglobin in ZnO Nanoparticle/ionic Liquid Composite Film Modified Glassy Carbon Electrode
    Wang, Dan-Dan
    Liu, He-Jian
    Zhao, Chang-Zhi
    Hui, Ni
    Sun, Wei
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2010, 57 (01) : 99 - 104