Direct electrochemistry and electrocatalytic properties of hemoglobin immobilized on a carbon ionic liquid electrode modified with mesoporous molecular sieve MCM-41

被引:25
|
作者
Li, Yonghong [1 ]
Zeng, Xiandong [1 ]
Liu, Xiaoying [1 ]
Liu, Xinsheng [2 ]
Wei, Wanzhi [1 ]
Luo, Shenglian [1 ]
机构
[1] Hunan Univ, State Key Lab Chemo Biosensing & Chemometr, Coll Chem & Chem Engn, Changsha 410082, Hunan, Peoples R China
[2] Hunan Nonferrous Fluoride Chem Co Ltd, Xiangxiang 411400, Hunan, Peoples R China
基金
美国国家科学基金会;
关键词
Hemoglobin; MCM-41; Carbon ionic liquid electrode; Direct electrochemistry; Hydrogen peroxide; BY-LAYER FILMS; PASTE ELECTRODE; CHITOSAN; SILICA; SILVER;
D O I
10.1016/j.colsurfb.2010.04.001
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The direct electron transfer and electrocatalysis of hemoglobin (Hb) entrapped in the MCM-41 modified carbon ionic liquid electrode (CILE) were investigated by using cyclic voltammetry in 0.10 M pH 7.0 phosphate buffer solution (PBS). Due to its uniform pore structure, high surface areas and good bio-compatibility, the mesoporous silica sieve MCM-41 provided a suitable matrix for immobilization of biomolecule. The MCM-41 modified CILE showed significant promotion to the direct electron transfer of Hb, which exhibited a pair of well defined and quasi-reversible peaks for heme Fe(III)/Fe(II) with a formal potential of -0.284V (vs. Ag/AgCl). Additionally, the Hb immobilized on the MCM-41 modified carbon ionic liquid electrode showed excellent electrocatalytic activity toward H2O2. The electrocatalytic current values were linear with increasing concentration of H2O2 in a wide range of 5-310 mu M and the corresponding detection limit was calculated to be 5 x 10(-8) M (S/N = 3). The surface coverage of Hb immobilized on the MCM-41 modified carbon ionic liquid electrode was about 2.54 x 10(-9) mol cm(-2). The Michaelis-Menten constant K-m(app) of 214 mu M indicated that the Hb immobilized on the modified electrode showed high affinity to H2O2. The proposed electrode had high stability and good reproducibility clue to the protection effect of MCM-41 and ionic liquid, and it would have wide potential applications in direct electrochemistry, biosensors and biocatalysis. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:241 / 245
页数:5
相关论文
共 50 条
  • [1] Direct Electrochemistry and Electrocatalytic Properties of Hemoglobin Immobilized on Carbon Nanotubes Ionic Liquid Electrode
    Moheimanian, Niloofar
    Raoof, Jahan Bakhsh
    Safavi, Afsaneh
    Ojani, Reza
    [J]. ELECTROANALYSIS, 2012, 24 (06) : 1386 - 1393
  • [2] Fabrication of carbon paste electrode containing 1:12 phosphomolybdic anions encapsulated in modified mesoporous molecular sieve MCM-41 and its electrochemistry
    Li, LD
    Li, WJ
    Sun, CQ
    Li, LS
    [J]. ELECTROANALYSIS, 2002, 14 (05) : 368 - 375
  • [3] Advances in mesoporous molecular sieve MCM-41
    Zhao, XS
    Lu, GQM
    Millar, GJ
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 1996, 35 (07) : 2075 - 2090
  • [4] Electrorheological properties of a suspension of a mesoporous molecular sieve (MCM-41)
    Choi, HJ
    Cho, MS
    Kang, KK
    Ahn, WS
    [J]. MICROPOROUS AND MESOPOROUS MATERIALS, 2000, 39 (1-2) : 19 - 24
  • [5] Direct Electrochemistry and Electrocatalysis of Hemoglobin on Bimetallic Au–Pt Inorganic–Organic Nanofiber Hybrid Nanocomposite and Mesoporous Molecular Sieve MCM-41
    Azadeh Azadbakht
    Amir Reza Abbasi
    Mohammad Bagher Gholivand
    Zohreh Derikvand
    [J]. Journal of Inorganic and Organometallic Polymers and Materials, 2014, 24 : 573 - 581
  • [6] Direct Electrochemistry of Hemoglobin Immobilized in Polyvinylalcohol and Clay Composite Film Modified Carbon Ionic Liquid Electrode
    Hui, Ni
    Gao, Rui-fang
    Li, Xiao-qing
    Sun, Wei
    Jiao, Kui
    [J]. JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2009, 20 (02) : 252 - 258
  • [7] Direct Electrochemistry of Hemoglobin in a Nafion and CuS Microsphere Modified Carbon Ionic Liquid Electrode and its Electrocatalytic Behavior
    Sun, W.
    Gao, R. -F.
    Zhao, R. -J.
    Zhu, H. -T.
    Jiao, K.
    [J]. JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2010, 7 (02) : 470 - 477
  • [8] Direct electrochemistry of hemoglobin in a nafion and CuS microsphere modified carbon ionic liquid electrode and its electrocatalytic behavior
    W. Sun
    R.-F. Gao
    R.-J. Zhao
    H.-T. Zhu
    K. Jiao
    [J]. Journal of the Iranian Chemical Society, 2010, 7 : 470 - 477
  • [9] CERIUM INCORPORATED INTO A MESOPOROUS MOLECULAR SIEVE (MCM-41)
    do Nascimento, G. E.
    Duarte, M. M. M. B.
    Barbosa, C. M. B. M.
    [J]. BRAZILIAN JOURNAL OF CHEMICAL ENGINEERING, 2016, 33 (03) : 541 - 547
  • [10] Synthesis of silica mesoporous molecular sieve MCM-41
    Zhang, B.
    Shen, L.
    Zhou, C.H.
    Cai, Y.
    Ge, Z.H.
    [J]. Gao Xiao Hua Xue Gong Cheng Xue Bao/Journal of Chemical Engineering of Chinese Universities, 2001, 15 (01): : 29 - 34