Studies of Positron Range in Tissue-Equivalent Materials

被引:0
|
作者
Alva-Sanchez, Hector [1 ]
Quintana-Bautista, Christian [2 ]
Martinez-Davalos, Arnulfo [1 ]
Angel Avila-Rodriguez, Miguel [3 ]
Rodriguez-Villafuerte, Mercedes [1 ]
机构
[1] Univ Nacl Autonoma Mexico, Inst Fis, AP 20-364, Mexico City 01000, DF, Mexico
[2] Univ Nacl Autonoma Mexico, Fac Ciencias, Mexico City, DF, Mexico
[3] Univ Nacl Autonoma Mexico, Fac Med, Mexico City, DF, Mexico
关键词
SPATIAL-RESOLUTION; PET;
D O I
10.1063/1.4954131
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In this work microPET scans and Monte Carlo simulations of line sources containing F-18, N-13 and Ga-68 were performed to study the effect that positron range has over the spatial resolution of PET images. The experimental studies were carried out using a microPET Focus 120 scanner with a reported axial spatial resolution of 1.44 mm. Line sources consisted of thin capillary tubes filled with a water solution containing a known activity concentration of the radionuclides and placed inside six different tissue equivalent cylindrical phantoms. Image reconstruction was performed using filtered backprojection and from the axial images, radial profiles were extracted to compute the spatial resolution for all radionuclide-material combinations. One dimensional line sources inside cylinders were simulated using PENELOPE to obtain the line spread functions (LSFs) of all the radionuclide-material combinations. Our results indicate that spatial resolution depends strongly on the radionuclide (positron energy) and the density of the tissue in which they travel before annihilation.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] Characterising breast tissue for the development of a tissue-equivalent phantom
    MJ Farquharson
    Breast Cancer Research, 2 (Suppl 2)
  • [42] A TISSUE-EQUIVALENT MODIFIED FBX DOSIMETRIC SYSTEM
    UPADHYAY, SN
    REDDY, AR
    GUPTA, MM
    NAGARATNAM, A
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1982, 33 (01): : 47 - 49
  • [43] TISSUE-EQUIVALENT DEVICES FOR MIXED FIELD DOSIMETRY
    LUCAS, AC
    HEALTH PHYSICS, 1970, 19 (02): : 328 - +
  • [44] Analysis of characteristics for tissue-equivalent chamber by simulation
    Li, Da
    Jiang, Xin-Biao
    Liu, Shu-Huan
    Quan, Lin
    Miao, Liang-Liang
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2010, 44 (04): : 469 - 473
  • [45] CRYOINJURY OF A CONTRACTILE TISSUE-EQUIVALENT: IN VITRO EXPERIMENTS
    Elkhalil, H.
    Bischof, J. C.
    Barocas, V. H.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE 2008, PTS A AND B, 2009, : 465 - 466
  • [46] ULTRASONIC SHEAR-WAVE PROPERTIES OF MAMMALIAN-TISSUES AND TISSUE-EQUIVALENT MATERIALS
    MADSEN, EL
    SATHOFF, HJ
    ZAGZEBSKI, JA
    GOODSITT, M
    ULTRASONIC IMAGING, 1980, 2 (02) : 186 - 186
  • [47] THERMALLY STIMULATED CURRENT IN TISSUE-EQUIVALENT MATERIALS FOR RADIATION-DOSIMETRY - PRELIMINARY ASSESSMENT
    HARPER, MW
    THOMAS, B
    PHYSICS IN MEDICINE AND BIOLOGY, 1973, 18 (03): : 409 - 420
  • [48] Tissue-equivalent proportional counters in radiation protection
    McDonald, JC
    RADIATION PROTECTION DOSIMETRY, 1998, 77 (03) : 147 - 149
  • [49] Linear attenuation coefficients of tissue-equivalent materials of differing compositions for low energy photons
    Sharma, RC
    Haridasan, TK
    HEALTH PHYSICS, 1999, 77 (02): : 196 - 199
  • [50] Assessment of doses caused by electrons in thin layers of tissue-equivalent materials, using MCNP
    Heide, Bernd