Studies of Positron Range in Tissue-Equivalent Materials

被引:0
|
作者
Alva-Sanchez, Hector [1 ]
Quintana-Bautista, Christian [2 ]
Martinez-Davalos, Arnulfo [1 ]
Angel Avila-Rodriguez, Miguel [3 ]
Rodriguez-Villafuerte, Mercedes [1 ]
机构
[1] Univ Nacl Autonoma Mexico, Inst Fis, AP 20-364, Mexico City 01000, DF, Mexico
[2] Univ Nacl Autonoma Mexico, Fac Ciencias, Mexico City, DF, Mexico
[3] Univ Nacl Autonoma Mexico, Fac Med, Mexico City, DF, Mexico
关键词
SPATIAL-RESOLUTION; PET;
D O I
10.1063/1.4954131
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In this work microPET scans and Monte Carlo simulations of line sources containing F-18, N-13 and Ga-68 were performed to study the effect that positron range has over the spatial resolution of PET images. The experimental studies were carried out using a microPET Focus 120 scanner with a reported axial spatial resolution of 1.44 mm. Line sources consisted of thin capillary tubes filled with a water solution containing a known activity concentration of the radionuclides and placed inside six different tissue equivalent cylindrical phantoms. Image reconstruction was performed using filtered backprojection and from the axial images, radial profiles were extracted to compute the spatial resolution for all radionuclide-material combinations. One dimensional line sources inside cylinders were simulated using PENELOPE to obtain the line spread functions (LSFs) of all the radionuclide-material combinations. Our results indicate that spatial resolution depends strongly on the radionuclide (positron energy) and the density of the tissue in which they travel before annihilation.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] ENDOTHERMIC PROCESSES IN TISSUE-EQUIVALENT PLASTIC
    FLEMING, DM
    GLASS, WA
    RADIATION RESEARCH, 1969, 37 (02) : 316 - &
  • [32] A TISSUE-EQUIVALENT GEL FOR NMR PHANTOMS
    DIXON, RL
    HINSON, WA
    EKSTRAND, KE
    MORAN, PR
    ROSEN, C
    MEDICAL PHYSICS, 1986, 13 (04) : 602 - 602
  • [33] NEW ULTRASOUND TISSUE-EQUIVALENT MATERIAL
    BURLEW, MM
    MADSEN, EL
    ZAGZEBSKI, JA
    BANJAVIC, RA
    SUM, SW
    RADIOLOGY, 1980, 134 (02) : 517 - 520
  • [34] Advancements in Tissue-Equivalent Gel Dosimeters
    Sagsoz, Mustafa Erdem
    Korkut, Ozlem
    Gallo, Salvatore
    GELS, 2025, 11 (02)
  • [35] Measurements of X-ray scatter signatures for some tissue-equivalent materials
    Poletti, ME
    Gonçalves, OD
    Mazzaro, I
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2004, 213 : 595 - 598
  • [36] TISSUE-EQUIVALENT PHANTOMS IN RADIOLOGICAL PROTECTION
    GUBATOVA, D
    VARCHENYA, V
    KRASTINYA, A
    KERNENERGIE, 1989, 32 (01): : 10 - 13
  • [37] DEVELOPMENT OF A TISSUE-EQUIVALENT PHANTOM FOR DIAPHANOGRAPHY
    LINFORD, J
    SHALEV, S
    BEWS, J
    BROWN, R
    SCHIPPER, H
    MEDICAL PHYSICS, 1986, 13 (06) : 869 - 875
  • [38] A TISSUE-EQUIVALENT UPPER ABDOMINAL PHANTOM
    SCHERZINGER, AL
    CARSON, PL
    CLAYMAN, W
    CARTER, W
    JOHNSON, ML
    RASHBAUM, C
    JOURNAL OF ULTRASOUND IN MEDICINE, 1983, 2 (10) : 455 - 462
  • [39] Evaluation of tissue-equivalent materials to be used as human brain tissue substitute in dosimetry for diagnostic radiology
    Ferreira, C. C.
    Ximenes Filho, R. E. M.
    Vieira, J. W.
    Tomal, A.
    Poletti, M. E.
    Garcia, C. A. B.
    Maia, A. F.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2010, 268 (16): : 2515 - 2521
  • [40] CALCULATED EFFECTIVE ATOMIC NUMBER AND KERMA VALUES FOR TISSUE-EQUIVALENT AND DOSIMETRY MATERIALS
    JAYACHANDRAN, CA
    PHYSICS IN MEDICINE AND BIOLOGY, 1971, 16 (04): : 617 - +