SEISMIC ANALYSIS OF GUANG DONG SCIENCE CENTRE WITH OR WITHOUT BASE-ISOLATION: A CASE STUDY

被引:0
|
作者
Zhu, Yong [1 ]
Su, R. K. L.
Zhang, Ji Chao [1 ]
机构
[1] Guangzhou Univ, Sch Civil Engn, Guangzhou, Guangdong, Peoples R China
关键词
damper; isolator; mega-frame; response spectrum; seismic analysis; time history analysis;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Guang Dong Science Centre (GDSC), located in the west of Guang Zhou Mega University City, is currently one of the most important landmark buildings in Guang Zhou of Guang Dong province. The special form and style, and the use of mega-frame and long-span internal space of the building, not surprisingly, presented great challenges for structural engineers. In particular, its dynamic performance under earthquake or wind actions requires intensive research. In this study, a detailed seismic analysis of GDSC has been conducted to investigate GDSC's seismic performance with or without the application of base-isolation. In this analysis, earthquake spectra generated for Guang Zhou region according to Chinese Code and Component Attenuation Method (CAM) were adopted to calculate the lateral displacements and distributions of base column forces. Furthermore, elastic and inelastic time-history seismic analyses were carried out using scaled accelerograms representing earthquake events with return periods of 50-year, 475-year, and 2475-years, respectively. The computational results indicate that the building with mega-frame system possesses substantial reserved strength for resisting earthquake loads, and the structure could satisfy the design requirements under severe seismic events. The output of this study is of considerable interest and practical use to professionals and researchers involving in the design of mega-frame buildings.
引用
收藏
页码:417 / 423
页数:7
相关论文
共 50 条
  • [1] SEISMIC PROTECTION OF ARTEFACTS WITH ADHESIVES AND BASE-ISOLATION
    Dong, Claire
    De Francesco, Giovanni
    Sullivan, Timothy
    Dhakal, Rajesh P.
    Elder, Terri
    Fryer, Emily
    Velagapudi, Neeha
    BULLETIN OF THE NEW ZEALAND SOCIETY FOR EARTHQUAKE ENGINEERING, 2023, 56 (03): : 186 - 200
  • [2] Seismic base-isolation by use of a telescoping stepping mechanism
    Martinez-Rodrigo, MD
    Luco, JE
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2005, 34 (03): : 227 - 245
  • [3] EVALUATION METHODOLOGY FOR SEISMIC BASE-ISOLATION OF NUCLEAR EQUIPMENTS
    EBISAWA, K
    UGA, T
    NUCLEAR ENGINEERING AND DESIGN, 1993, 142 (2-3) : 319 - 326
  • [4] SEISMIC RESPONSE OF HEAVILY DAMPED BASE-ISOLATION SYSTEMS
    TSAI, HC
    KELLY, JM
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1993, 22 (07): : 633 - 645
  • [5] Seismic design optimization considering base-isolation system
    Ivanov, A. Y.
    Chernogorskiy, S. A.
    Vlasov, M. P.
    MAGAZINE OF CIVIL ENGINEERING, 2018, 80 (04): : 138 - 150
  • [6] Analysis of Base-Isolation building system
    Ni, Guowei
    Jiang, Dengling
    Qi, Jiarui
    Chen, Juannong
    ADVANCES IN CIVIL ENGINEERING AND ARCHITECTURE INNOVATION, PTS 1-6, 2012, 368-373 : 807 - +
  • [7] Nonlinear seismic analysis of RC framed structures with horizontal and vertical base-isolation
    Mazza, Fabio
    XIX ANIDIS CONFERENCE, SEISMIC ENGINEERING IN ITALY, 2023, 44 : 1172 - 1179
  • [8] Study of base-isolation building system
    Ni, G.W.
    Zhang, Y.M.
    Jiang, D.L.
    Chen, J.N.
    Liu, B.
    World Academy of Science, Engineering and Technology, 2010, 46 : 334 - 338
  • [9] Seismic Performance Analysis of A Smart Base-isolation System Considering Dynamics of MR Elastomers
    Jung, Hyung-Jo
    Eem, Seung-Hyun
    Jang, Dong-Doo
    Koo, Jeong-Hoi
    JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2011, 22 (13) : 1439 - 1450
  • [10] Static vulnerability of an existing r.c. structure and seismic retrofitting by CFRP and base-isolation: A case study
    Mazza, Fabio
    Pucci, Daniela
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2016, 84 : 1 - 12