Use of a real time continuous glucose monitoring system as an educational tool for patients with gestational diabetes

被引:30
|
作者
Alfadhli, Eman [1 ]
Osman, Eman [1 ]
Basri, Taghreed [2 ]
机构
[1] Taibah Univ, Medina, Saudi Arabia
[2] Madina Matern & Children Hosp, Medina, Saudi Arabia
来源
关键词
Gestational diabetes; Continuous glucose monitoring system; SMBG; Maternal glycemic control; Pregnancy outcomes; GLYCEMIC CONTROL; PREGNANCY;
D O I
10.1186/s13098-016-0161-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Women with gestational diabetes mellitus (GDM) are required to control their blood glucose shortly after GDM diagnosis to minimize adverse pregnancy outcomes. A real time-continuous glucose monitoring system (RT-CGMS) provides the patient with continuous information about the alterations in levels of the blood glucose. This visibility may empower the patient to modify her lifestyle and engage in therapeutic management. The aim of this study was to determine whether a single application of RT-CGMS to pregnant women shortly after GDM diagnosis is useful as an educational and motivational tool. Methods: This study was a prospective open label randomized controlled study conducted at Maternity and Children Hospital, Medina, Saudi Arabia. A total of 130 pregnant women with GDM were randomised to either blood glucose self-monitor alone (SMBG group) (n = 62) or in addition to SMBG, patients wore a Guardian (R) REAL-Time Continuous Glucose Monitoring System (Medtronic MiniMed) once for 3-7 days, within 2 weeks of GDM diagnosis (RT-CGMS group) (n = 68). The primary outcomes were maternal glycemic control and pregnancy outcomes. Secondary outcomes were the changes in parameters of glucose variability, which includes mean sensor readings, standard deviation (SD) of blood glucose, and area under the curve for hyper and hypoglycaemia at the end of the RT-CGMS application. Results: HbA1c, mean fasting and postprandial glucose levels were similar in both groups at the end of the pregnancy. Pregnancy outcomes were comparable. However, there was significant improvement in the parameters of glucose variability on the last day of sensor application; both mean glucose and the SD of mean glycaemia were reduced significantly; P = 0.016 and P = 0.034, respectively. The area under the curve for hyper and hypoglycaemia were improved, however, the results were not statistically significant. Conclusion: Although a single application of RT-CGMS shortly after GDM diagnosis is helpful as an educational tool, it was not associated with improvement in glycemic control or pregnancy outcomes.
引用
下载
收藏
页数:7
相关论文
共 50 条
  • [11] Guardian® RT Continuous Glucose Monitoring System with real time glucose values and alarms functions:: a new tool for improving glucose control in patients with type 1 diabetes mellitus?
    Bolinder, J
    Deiss, D
    Riveline, J
    Battelino, T
    Bosi, E
    Tubiana-Rufi, N
    Kerr, D
    Phillip, M
    DIABETOLOGIA, 2005, 48 : A49 - A49
  • [12] Evaluation of a new real-time blood continuous glucose monitoring system in pregnant women without gestational diabetes - A pilot study
    Porter, H
    Lookinland, S
    Belfort, MA
    JOURNAL OF PERINATAL & NEONATAL NURSING, 2004, 18 (02) : 93 - 102
  • [13] Clinical Use of Real-Time Continuous Glucose Monitoring
    Battelino, Tadej
    Bolinder, Jan
    CURRENT DIABETES REVIEWS, 2008, 4 (03) : 218 - 222
  • [14] Use of real time continuous glucose monitoring in type 1 diabetes patients on intraperitoneal insulin (CIPII). A feasibility study
    Bilo, H. J. G.
    Groenier, K. H.
    Kleefstra, N.
    Logtenberg, S. J. J.
    DIABETOLOGIA, 2008, 51 : S437 - S438
  • [16] DIABETES Under Control Real-Time Continuous Glucose Monitoring
    Ramchandani, Neesha
    Saadon, Yael
    Jornsay, Donna
    AMERICAN JOURNAL OF NURSING, 2010, 110 (04) : 60 - 63
  • [17] Use of Flash-Glucose-Monitoring Systems for Patients with Gestational Diabetes
    Weschenfelder, F.
    Schleussner, E.
    Groten, T.
    GEBURTSHILFE UND FRAUENHEILKUNDE, 2021, 81 (06) : E54 - E54
  • [18] The use of real time continuous glucose monitoring or flash glucose monitoring in the management of diabetes: A consensus view of Italian diabetes experts using the Delphi method
    Bruttomesso, D.
    Laviola, L.
    Avogaro, A.
    Bonora, E.
    Del Prato, S.
    Frontoni, S.
    Orsi, E.
    Rabbone, I
    Sesti, G.
    Purrello, F.
    NUTRITION METABOLISM AND CARDIOVASCULAR DISEASES, 2019, 29 (05) : 421 - 431
  • [19] Use of Continuous Glucose Monitoring in Patients with Type 1 Diabetes
    Ellis, Samuel L.
    Naik, Ramachandra G.
    Gemperline, Kate
    Garg, Satish K.
    CURRENT DIABETES REVIEWS, 2008, 4 (03) : 207 - 217
  • [20] The Use of Continuous Glucose Monitoring in Patients with Type 2 Diabetes
    Meade, Lisa T.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2012, 14 (02) : 190 - 195