Clinical Use of Real-Time Continuous Glucose Monitoring

被引:24
|
作者
Battelino, Tadej [1 ]
Bolinder, Jan [2 ]
机构
[1] UMC Univ Childrens Hosp, Vrazov Trg 1, Ljubljana 1000, Slovenia
[2] Karolinska Univ Hosp Huddinge, Karolinska Inst, Dept Med, Stockholm, Sweden
关键词
D O I
10.2174/157339908785294352
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Maintaining near-normal glycaemia in all patients with diabetes mellitus (DM) has become a standard and a well accepted recommendation. Unfortunately, most people with DM do not achieve this clinical goal because of marked glycaemic fluctuations and hypoglycaemia. Real-time continuous glucose monitoring (RT-CGM) has been introduced recently into clinical practice offering more knowledge about current glucose concentration and trend and enabling people with DM to intervene and prevent unwanted glucose excursions by acting upon real-time and predictive alarms. Several RT-CGM devices proved to be sufficiently accurate and feasible for routine use. Observational reports with The Guardian and Paradigm RT by Medtronic, the STS by DexCom, FreeStyle Navigator by Abbott and GlucoDay by Menarini established initial clinical benefit. Five randomised controlled trials (RCT) demonstrated significantly improved glucose variability or metabolic control, one of them showing a statistically significant and clinically meaningful decrease of HbA1c with a 3 months use of the Guardian RT (Medtronic, Northridge, CA). The great potential of RT-CGM devices to improve daily glucose control and quality of life in people with DM can only be developed further through RCTs, clarifying in more details the optimal clinical use and the most beneficial indications for this novel technique.
引用
收藏
页码:218 / 222
页数:5
相关论文
共 50 条
  • [1] Real-time continuous glucose monitoring: proven clinical indiciations
    Gomez Peralta, Fernando
    Abreu Padin, Cristina
    [J]. AVANCES EN DIABETOLOGIA, 2011, 27 (06): : 198 - 203
  • [2] Clinical Implications of Real-time and Intermittently Scanned Continuous Glucose Monitoring
    Edelman, Steven V.
    Argento, Nicholas B.
    Pettus, Jeremy
    Hirsch, Irl B.
    [J]. DIABETES CARE, 2018, 41 (11) : 2265 - 2274
  • [3] Type 2 Diabetes and the Use of Real-Time Continuous Glucose Monitoring
    Jackson, Melanie A.
    Ahmann, Andrew
    Shah, Viral N.
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 : S27 - S34
  • [4] Reduced Glycemic Variability with the Use of Real-Time Continuous Glucose Monitoring
    Rodbard, David
    Jovanovic, Lois
    Garg, Satish K.
    Matsubara, Bradley S.
    Nakamura, Katherine
    Bailey, Timothy
    Zisser, Howard
    Kaplan, Roy
    [J]. DIABETES, 2009, 58 : A55 - A55
  • [5] Real-time continuous glucose monitoring in the ICU
    J Gios
    B Manuel-y-Keenoy
    P Rogiers
    [J]. Critical Care, 19 (Suppl 1):
  • [6] Practical Aspects of Real-Time Continuous Glucose Monitoring
    Gilliam, Lisa K.
    Hirsch, Irl B.
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2009, 11 : S75 - S82
  • [7] Real-Time Continuous Glucose Monitoring in Preterm Infants
    Joseph, Rachel
    Rosa, Jenna Hope-Altomari
    [J]. NEONATAL NETWORK, 2022, 41 (06): : 376 - 376
  • [8] Reliability of real-time continuous glucose monitoring in infants
    Tomotaki, Seiichi
    Toyoshima, Katsuaki
    Shimokaze, Tomoyuki
    Kawai, Masahiko
    [J]. PEDIATRICS INTERNATIONAL, 2019, 61 (10) : 1001 - 1006
  • [9] Real-Time Improvement of Continuous Glucose Monitoring Accuracy
    Facchinetti, Andrea
    Sparacino, Giovanni
    Guerra, Stefania
    Luijf, Yoeri M.
    DeVries, J. Hans
    Mader, Julia K.
    Ellmerer, Martin
    Benesch, Carsten
    Heinemann, Lutz
    Bruttomesso, Daniela
    Avogaro, Angelo
    Cobelli, Claudio
    [J]. DIABETES CARE, 2013, 36 (04) : 793 - 800
  • [10] Benefits of Real-Time Continuous Glucose Monitoring in Pregnancy
    Yamamoto, Jennifer M.
    Murphy, Helen R.
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 : S8 - S14