Mechanical properties of dura mater from the rat brain and spinal cord

被引:133
|
作者
Maikos, Jason T. [1 ]
Elias, Ragi A. I. [1 ]
Shreiber, David I. [1 ]
机构
[1] Rutgers State Univ, Dept Biomed Engn, Piscataway, NJ 08854 USA
关键词
constitutive modeling; injury biomechanics; spinal cord injury; tissue mechanics; traumatic brain injury; viscoelasticity;
D O I
10.1089/neu.2007.0348
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The dura mater is the outermost and most substantial meningial layer of central nervous system (CNS) tissue that acts as a protective membrane for the brain and spinal cord. In animal models of traumatic brain injury and spinal cord injury, mechanical insults are often delivered directly to the dura to injure the underlying tissue. As such, including a description of the mechanical properties of dura mater is critical for biomechanical analyses of these models. We have characterized the mechanical response of dura mater from the rat brain and spinal cord in uniaxial tension. Testing was performed at low (0.0014 sec(-1)) and high (19.42 sec(-1)) strain rates. Both rat cranial dura and spinal dura demonstrated non-linear stress-strain responses characteristic of collagenous soft tissues. The non-linear increase in stress lagged in the spinal dura compared to the cranial dura. The slow rate data was fit to a one-term Ogden hyperelastic constitutive law, and significant differences were observed for the stiffness, G, and the parameter, alpha, which nominally introduces non-linearity. High strain rate stress-relaxation tests were performed to 10% strain, which was held for 10 sec. The relaxation was fit to a four-term Prony series exponential decay. Cranial dura and spinal dura demonstrated similar overall relaxation, but significant differences were identified in the distribution of the relaxation over the Prony series parameters, which demonstrated that cranial dura tended to relax faster. Polarized light microscopy revealed that the structural entities of spinal dura were aligned in the axial direction, whereas cranial dura did not demonstrate a preferential alignment. This was confirmed qualitatively with Masson's Tri-chrome and Verhoeff's Van Gieson staining for collagen and elastin, which also indicated greater elastin content for the spinal dura than for the cranial dura.
引用
收藏
页码:38 / 51
页数:14
相关论文
共 50 条
  • [41] SOME DATA CONCERNING ARTERIOLE-VENULE ANASTOMOSES IN DURA MATER OF HUMAN SPINAL-CORD
    RESHETILOV, VI
    ZHURNAL NEVROPATOLOGII I PSIKHIATRII IMENI S S KORSAKOVA, 1978, 78 (07): : 1003 - 1008
  • [42] BIOGENIC MONOAMINES IN THE PIA MATER OF THE VERTEBRATE BRAIN AND SPINAL-CORD
    MOTAVKIN, PA
    PIGOLKIN, YI
    LOMAKIN, AV
    KREIMER, DI
    JOURNAL OF EVOLUTIONARY BIOCHEMISTRY AND PHYSIOLOGY, 1989, 25 (05) : 406 - 409
  • [43] Damage accumulation modeling and rate dependency of spinal dura mater
    Ramo, Nicole
    Shetye, Snehal S.
    Puttlitz, Christian M.
    Journal of Engineering and Science in Medical Diagnostics and Therapy, 2018, 1 (01)
  • [44] Mechanical properties of solvent-dehydrated bovine pericardium xenograft for dura mater repair
    Quaglini, V.
    Villa, T.
    JOURNAL OF APPLIED BIOMATERIALS & BIOMECHANICS, 2007, 5 (01) : 34 - 40
  • [45] Histological Investigation of Resected Dura Mater Attached to Spinal Meningioma
    Yamamuro, Kenichi
    Seichi, Atsushi
    Kimura, Atsushi
    Kikkawa, Ichiro
    Kojima, Masahiro
    Inoue, Hirokazu
    Hoshino, Yuichi
    SPINE, 2012, 37 (22) : E1398 - E1401
  • [46] PRESUMED MYELOPOIESIS IN SPINAL DURA MATER OF NORMAL BOVINE FETUSES
    TERLECKI, S
    BRADLEY, R
    JOURNAL OF COMPARATIVE PATHOLOGY, 1983, 93 (03) : 347 - 352
  • [47] DAMAGE ACCUMULATION MODELING AND RATE DEPENDENCY OF SPINAL DURA MATER
    Ramo, Nicole L.
    Shetye, Snehal S.
    Puttlitz, Christian M.
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2017, VOL 3, 2018,
  • [48] Dopaminergic receptors in rat dura mater: Pharmacological characteristics
    Cavallotti, C
    Frati, A
    Cavallotti, D
    Leali, FMT
    CLINICAL AND EXPERIMENTAL PHARMACOLOGY AND PHYSIOLOGY, 2004, 31 (03): : 190 - 194
  • [49] Investigation of connective tissue attachments to the cervical spinal dura mater
    Humphreys, BK
    Kenin, S
    Hubbard, BB
    Cramer, GD
    CLINICAL ANATOMY, 2003, 16 (02) : 152 - 159
  • [50] The spinal cord dura mater reaction to nitinol and titanium alloy particles: a 1-year study in rabbits
    Souad Rhalmi
    Sylvie Charette
    Michel Assad
    Christine Coillard
    Charles H. Rivard
    European Spine Journal, 2007, 16 : 1063 - 1072