Mechanical properties of dura mater from the rat brain and spinal cord

被引:133
|
作者
Maikos, Jason T. [1 ]
Elias, Ragi A. I. [1 ]
Shreiber, David I. [1 ]
机构
[1] Rutgers State Univ, Dept Biomed Engn, Piscataway, NJ 08854 USA
关键词
constitutive modeling; injury biomechanics; spinal cord injury; tissue mechanics; traumatic brain injury; viscoelasticity;
D O I
10.1089/neu.2007.0348
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The dura mater is the outermost and most substantial meningial layer of central nervous system (CNS) tissue that acts as a protective membrane for the brain and spinal cord. In animal models of traumatic brain injury and spinal cord injury, mechanical insults are often delivered directly to the dura to injure the underlying tissue. As such, including a description of the mechanical properties of dura mater is critical for biomechanical analyses of these models. We have characterized the mechanical response of dura mater from the rat brain and spinal cord in uniaxial tension. Testing was performed at low (0.0014 sec(-1)) and high (19.42 sec(-1)) strain rates. Both rat cranial dura and spinal dura demonstrated non-linear stress-strain responses characteristic of collagenous soft tissues. The non-linear increase in stress lagged in the spinal dura compared to the cranial dura. The slow rate data was fit to a one-term Ogden hyperelastic constitutive law, and significant differences were observed for the stiffness, G, and the parameter, alpha, which nominally introduces non-linearity. High strain rate stress-relaxation tests were performed to 10% strain, which was held for 10 sec. The relaxation was fit to a four-term Prony series exponential decay. Cranial dura and spinal dura demonstrated similar overall relaxation, but significant differences were identified in the distribution of the relaxation over the Prony series parameters, which demonstrated that cranial dura tended to relax faster. Polarized light microscopy revealed that the structural entities of spinal dura were aligned in the axial direction, whereas cranial dura did not demonstrate a preferential alignment. This was confirmed qualitatively with Masson's Tri-chrome and Verhoeff's Van Gieson staining for collagen and elastin, which also indicated greater elastin content for the spinal dura than for the cranial dura.
引用
收藏
页码:38 / 51
页数:14
相关论文
共 50 条
  • [1] Mechanical properties of porcine spinal dura mater and pericranium
    Cavelier, S.
    Quarrington, R. D.
    Jones, C. F.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2022, 126
  • [2] BIAXIAL RESPONSE OF OVINE SPINAL CORD DURA MATER
    Shetye, Snehal S.
    Puttlitz, Christian M.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2013, PT A, 2014,
  • [3] Mechanical properties of lumbar dura mater and biomechanics of spinal anesthesia procedure
    Pietrabissa, R
    Mantero, S
    Quaglini, V
    Contro, R
    Runza, M
    COMPUTER METHODS IN BIOMECHANICS & BIOMEDICAL ENGINEERING - 2, 1998, : 355 - 362
  • [4] Biaxial response of ovine spinal cord dura mater
    Shetye, Snehal S.
    Deault, Matthew M.
    Puttlitz, Christian M.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2014, 34 : 146 - 153
  • [5] Mechanical properties of cervical dura mater
    Mazgajczyk, Emilia
    Scigala, Krzysztof
    Czyz, Marcin
    Jarmundowicz, Wlodzimierz
    Bedzinski, Romuald
    ACTA OF BIOENGINEERING AND BIOMECHANICS, 2012, 14 (01) : 51 - 58
  • [6] A Technique for In Vitro Studying of the Permeability of the Spinal Cord Dura Mater
    V. V. Krasnov
    M. V. Stogov
    T. A. Silant’eva
    N. V. Kubrak
    E. A. Kireeva
    Bulletin of Experimental Biology and Medicine, 2018, 164 : 402 - 403
  • [7] A case of idiopathic spinal cord herniation with duplicated dura mater
    Sugimoto, T
    Kasai, Y
    Takegami, K
    Morimoto, R
    Maeda, M
    Uchida, A
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2005, 18 (01): : 106 - 111
  • [8] A Technique for In Vitro Studying of the Permeability of the Spinal Cord Dura Mater
    Krasnov, V. V.
    Stogov, M. V.
    Silant'eva, T. A.
    Kubrak, N. V.
    Kireeva, E. A.
    BULLETIN OF EXPERIMENTAL BIOLOGY AND MEDICINE, 2018, 164 (03) : 402 - 403
  • [9] Response properties of trigeminal brain stem neurons with input from dura mater encephali in the rat
    Schepelmann, K
    Ebersberger, A
    Pawlak, M
    Oppmann, M
    Messlinger, K
    NEUROSCIENCE, 1999, 90 (02) : 543 - 554
  • [10] Tensile properties of human spinal dura mater and pericranium
    Cavelier, Sacha
    Quarrington, Ryan D.
    Jones, Claire F.
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2022, 34 (01)