Analysis of Power System Frequency Responses With Hydro Turbines Incorporating Load Shedding

被引:0
|
作者
Gao, Lin [1 ]
Xia, Junrong [1 ]
Dai, Yiping [1 ]
机构
[1] Xi An Jiao Tong Univ, Inst Turbomachinery, Xian 710049, Peoples R China
关键词
frequency response model; hydro power sytem; load shedding;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
As shown in many recent works, the load-frequency behavior can be represented by system frequency response models especially for an islanding process. In this paper, a frequency response model incorporating an under-frequency load-shedding scheme is presented for islanding power system simulations. The model was applied for a practical power system with both hydro and fossil-fired power generators. The governing system models are involved in the model, which have great impact on the system dynamics. Parameter identification method is used to find and verify the model parameters. Similar responses were observed between the simulations and the accident records. The simulation results showed disadvantages of the primary frequency control systems of hydro power generators at the beginning of the load disturbances. An closed fossil fired power plant is proposed to serve against the load disturbances and improved stability was observed according to the system simulation results.
引用
收藏
页码:328 / 332
页数:5
相关论文
共 50 条
  • [1] The effect of hydro turbines and governors on power system low frequency oscillations
    Li, Xianshan
    Zhang, Chunli
    Zhu, Jianguo
    Hu, Xiangyong
    2006 INTERNATIONAL CONFERENCE ON POWER SYSTEMS TECHNOLOGY: POWERCON, VOLS 1- 6, 2006, : 2191 - 2194
  • [2] Optimal algorithm of low frequency load shedding in power system
    Li, Xiuqing
    Cai, Zexiang
    Dianli Xitong Zidonghue/Automation of Electric Power Systems, 1998, 22 (10): : 23 - 25
  • [3] Under-frequency Load Shedding Strategy for Power System Based on Analytical Frequency Response Model of Doubly-fed Wind Turbines
    Jiang C.
    Cai G.
    Yang D.
    Liu C.
    Sun Z.
    Liu X.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2023, 47 (21): : 108 - 118
  • [4] POWER SYSTEM MODELING FOR SELECTION OF AUTOMATIC FREQUENCY LOAD-SHEDDING
    SHCHERBINA, YV
    MELNIK, VP
    ROITELMAN, IG
    ELECTRICAL TECHNOLOGY, 1980, (02): : 53 - 63
  • [5] Underfrequency Load Shedding with Forecasting of the Power System's Frequency Response
    Rudez, Urban
    Mihalic, Rafael
    INTERNATIONAL REVIEW OF ELECTRICAL ENGINEERING-IREE, 2012, 7 (02): : 3969 - 3978
  • [6] ANALYSIS OF AUTOMATIC FREQUENCY LOAD SHEDDING DURING POWER SYSTEM OUT-OF-STEP CONDITIONS
    RABINOVI.RS
    ELECTRICAL TECHNOLOGY, 1969, 1 : 160 - &
  • [7] A method for frequency dynamics analysis and load shedding assessment based on the trajectory of power system simulation
    Li, Aimin
    Cai, Zexiang
    2008 THIRD INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES, VOLS 1-6, 2008, : 1335 - 1339
  • [8] Revised load shedding schedule for power system incorporating the effect of transmission line performance
    Chandekar, SM
    Tarnekar, SG
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2002, 24 (05) : 379 - 386
  • [9] Automatic frequency load shedding in power systems
    Pavlov, G.M.
    Merkur'ev, A.G.
    Shargin, Yu.M.
    Shiyou Xuebao, Shiyou Jiagong/Acta Petrolei Sinica (Petroleum Processing Section), 1998, 14 (04): : 23 - 27
  • [10] Automatic load shedding in power system
    Perumal, N
    Amran, AC
    NATIONAL POWER ENGINEERING CONFERENCE PECON 2003, PROCEEDINGS, 2003, : 211 - 216