Analysis of Power System Frequency Responses With Hydro Turbines Incorporating Load Shedding

被引:0
|
作者
Gao, Lin [1 ]
Xia, Junrong [1 ]
Dai, Yiping [1 ]
机构
[1] Xi An Jiao Tong Univ, Inst Turbomachinery, Xian 710049, Peoples R China
来源
ICIEA 2010: PROCEEDINGS OF THE 5TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOL 2 | 2010年
关键词
frequency response model; hydro power sytem; load shedding;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
As shown in many recent works, the load-frequency behavior can be represented by system frequency response models especially for an islanding process. In this paper, a frequency response model incorporating an under-frequency load-shedding scheme is presented for islanding power system simulations. The model was applied for a practical power system with both hydro and fossil-fired power generators. The governing system models are involved in the model, which have great impact on the system dynamics. Parameter identification method is used to find and verify the model parameters. Similar responses were observed between the simulations and the accident records. The simulation results showed disadvantages of the primary frequency control systems of hydro power generators at the beginning of the load disturbances. An closed fossil fired power plant is proposed to serve against the load disturbances and improved stability was observed according to the system simulation results.
引用
收藏
页码:328 / 332
页数:5
相关论文
共 50 条
  • [31] Load Frequency Control for Power Systems with Wind Turbines
    Chen Wen
    Tan Wen
    2014 33RD CHINESE CONTROL CONFERENCE (CCC), 2014, : 4277 - 4282
  • [32] Select Location for Load Shedding In Power System
    Trong Nghia Le
    Huy Anh Quyen
    Thi Thanh Binh Phan
    Ngoc Au Nguyen
    Tan Phung Trieu
    PROCEEDINGS OF 2018 4TH INTERNATIONAL CONFERENCE ON GREEN TECHNOLOGY AND SUSTAINABLE DEVELOPMENT (GTSD), 2018, : 13 - 17
  • [33] Determination of frequency stability border of power system to set the thresholds of under frequency load shedding relays
    Amjady, Nima
    Fallahi, Farzad
    ENERGY CONVERSION AND MANAGEMENT, 2010, 51 (10) : 1864 - 1872
  • [34] Load Frequency Control of Three Area Hydro Thermal Power System with HFTID Controller
    Kumar, Ajay
    Dahiya, Ratna
    2014 IEEE 6th India International Conference on Power Electronics (IICPE), 2014,
  • [35] Method for generation shedding and load shedding in power system emergency control
    Zhang, Ruiqi
    Min, Yong
    Hou, Kaiyuan
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2003, 27 (18): : 6 - 12
  • [36] Application of a Hybrid Controller in Load Frequency Control of Hydro-thermal Power System
    Tushir, Meena
    Srivastava, Smriti
    2012 IEEE FIFTH POWER INDIA CONFERENCE, 2012,
  • [37] Load Frequency Control for a Distributed Grid System Involving Wind and Hydro Power Generation
    Sahoo, Ashwin Kumar
    Chitra, V
    Kanagapriya, T.
    2012 2ND INTERNATIONAL CONFERENCE ON POWER, CONTROL AND EMBEDDED SYSTEMS (ICPCES 2012), 2012,
  • [38] Robot control system for grinding of large hydro power turbines
    Thomessen, T
    Lien, TK
    Sannæs, PK
    INDUSTRIAL ROBOT, 2001, 28 (04): : 328 - 334
  • [39] Under Frequency Load Shedding Plan in Active Power Systems: Analysis and Innovative Proposals
    Scirocco, T. Baffa
    Bruno, G.
    Caciolli, L.
    Giannuzzi, G.
    Zaottini, R.
    Giorgi, A.
    Grasso, F.
    Rossi, G.
    2018 AEIT INTERNATIONAL ANNUAL CONFERENCE, 2018,
  • [40] Load Shedding control Strategy for power system Based on the system frequency and voltage stability(Apr 2018)
    Zhao Jianjun
    Zhou Dong
    Gao Yang
    Yu Zhihong
    2018 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2018, : 1352 - 1356