Revised load shedding schedule for power system incorporating the effect of transmission line performance

被引:6
|
作者
Chandekar, SM [1 ]
Tarnekar, SG [1 ]
机构
[1] NIT Lay Out, Nagpur 440022, Maharashtra, India
关键词
under-frequency; revised load-shedding; transmission line;
D O I
10.1016/S0142-0615(01)00035-7
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
There is a growing trend towards the use of sophisticated relays like frequency trend relays for the purpose of automatic load shedding to avert the major system collapses due to integrated operation of modern power system. Accurate load shedding saves loss of revenue to power utility in addition to avoiding unnecessary disruption of vital feeders. Face values of NW capacities of generation outages are normally used for estimating the system overloading and consequent quantum of load shed to recover the system to safe workable frequency. Inherent dependence of transmission line parameters upon the system frequency affects the line performance in terms of its reduced output during under-frequency condition. The paper has attempted to present a modified load shedding scheme incorporating the relieving effect of transmission network and showed the advantages over the conventional method. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:379 / 386
页数:8
相关论文
共 50 条
  • [1] Analysis of Power System Frequency Responses With Hydro Turbines Incorporating Load Shedding
    Gao, Lin
    Xia, Junrong
    Dai, Yiping
    ICIEA 2010: PROCEEDINGS OF THE 5TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOL 2, 2010, : 328 - 332
  • [2] Automatic load shedding in power system
    Perumal, N
    Amran, AC
    NATIONAL POWER ENGINEERING CONFERENCE PECON 2003, PROCEEDINGS, 2003, : 211 - 216
  • [3] Effect of rotational load shedding on overall power system adequacy indices
    Billinton, R
    Satish, J
    IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 1996, 143 (02) : 181 - 187
  • [4] Use of transmission line having SPFC for alleviation of line over load of transmission line of an interconnected power system
    Hazarika, Durlav
    Das, Bonita
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2014, 63 : 722 - 729
  • [5] Dynamic performance of a long transmission line incorporating static VAR system
    Dave, M.P.
    Kumar, N.
    Modelling, Measurement & Control A: General Physics, Electronics,Electrical Engineering, 1994, 56 (2-4): : 41 - 52
  • [6] Protective relay setting of the tie line tripping and load shedding for the industrial power system
    Chen, CS
    Ke, YL
    Hsu, CT
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2000, 36 (05) : 1226 - 1234
  • [7] Power system computer controlled load shedding
    Moya, O
    ELECTRIC POWER SYSTEMS RESEARCH, 1996, 37 (03) : 165 - 171
  • [8] Select Location for Load Shedding In Power System
    Trong Nghia Le
    Huy Anh Quyen
    Thi Thanh Binh Phan
    Ngoc Au Nguyen
    Tan Phung Trieu
    PROCEEDINGS OF 2018 4TH INTERNATIONAL CONFERENCE ON GREEN TECHNOLOGY AND SUSTAINABLE DEVELOPMENT (GTSD), 2018, : 13 - 17
  • [9] Method for generation shedding and load shedding in power system emergency control
    Zhang, Ruiqi
    Min, Yong
    Hou, Kaiyuan
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2003, 27 (18): : 6 - 12
  • [10] Effect of Advanced Static VAR Compensator on Control of Power System Load Shedding
    Rao, B. Venkateswara
    Kumar, G. V. Nagesh
    Kumari, R. V. S. Lakshmi
    Kumar, M. Vinay
    MEMS, NANO AND SMART SYSTEMS, PTS 1-6, 2012, 403-408 : 4867 - +