Graphitized mesoporous carbon modified glassy carbon electrode for selective sensing of xanthine, hypoxanthine and uric acid

被引:60
|
作者
Thangaraj, Rajendiran [1 ]
Kumar, Annamalai Senthil [1 ]
机构
[1] Vellore Inst Technol Univ, Sch Adv Sci, Environm & Analyt Chem Div, Vellore 632014, Tamil Nadu, India
关键词
PERFORMANCE LIQUID-CHROMATOGRAPHY; PYROCHLORE MODIFIED ELECTRODE; ELECTROCATALYTIC OXIDATION; ASCORBIC-ACID; CAPILLARY-ELECTROPHORESIS; AMPEROMETRIC DETECTION; PURINE DERIVATIVES; PASTE ELECTRODE; SEPARATION; SENSOR;
D O I
10.1039/c2ay25029b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An efficient electrochemical sensor for simultaneous electrochemical sensing of three purine compounds, uric acid (UA), xanthine (X) and hypoxanthine (HX), using a graphitized mesoporous carbon (GMC) modified glassy carbon electrode (GCE/GMC) has been demonstrated in pH 7 phosphate buffer solution without any enzyme, prior to electrode activation, surfactant and sample pre-concentration step. Electrochemical investigation of the GCE/GMC with [Fe(CN)(6)](3-) indicates metallic conductor like surface features of the modified electrode. A diffusion controlled reaction mechanism was identified for the electro-oxidation of the three purine compounds with an electrocatalytic pathway, except for the UA, where it shows a surface area effect with a mixed-diffusion and adsorption controlled mechanism at higher scan rates (>70 mV s(-1)). Calculated full-width of the half maximum values for the simultaneous detection of the three purine compounds are 42, 53 and 64 mV respectively and these are the lowest values ever reported in the literature, suggesting effective electron-transfer behaviour of the modified electrode for the purine oxidations. Calibration plots for the simultaneous detection of the purine compounds were linear in the concentration range of 20-400 mu M, 20-320 mu M and 20-240 mu M for UA, X and HX with detection limit values of 110 nM, 388 nM, and 351 nM respectively. Selective sensing of the purine compounds in human blood-plasma, urine and fish samples was successfully demonstrated with recovery values similar to 100%.
引用
收藏
页码:2162 / 2171
页数:10
相关论文
共 50 条
  • [31] Selective determination of dopamine in the presence of high concentration ascorbic acid and uric acid using carbon nanotube modified glassy carbon electrode
    Sun, YY
    Wu, KB
    Hu, SS
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2002, 23 (11): : 2067 - 2069
  • [32] SIMULTANEOUS DETERMINATION OF URIC-ACID, XANTHINE AND HYPOXANTHINE WITH AN ELECTROCHEMICALLY PRETREATED CARBON-PASTE ELECTRODE
    CAI, X
    KALCHER, K
    NEUHOLD, C
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 348 (10): : 660 - 665
  • [33] Selective Determination of Uric Acid, Tryptphan, and Serotonin at Glassy Carbon Paste Electrode
    Nishiyama, Katsuhiko
    Inada, Kazufumi
    Taniguchi, Isao
    ELECTROCHEMISTRY, 2010, 78 (02) : 165 - 169
  • [34] Selective Simultaneous Determination of Paracetamol and Uric Acid Using a Glassy Carbon Electrode Modified with Multiwalled Carbon Nanotube/Chitosan Composite
    Babaei, Ali
    Garrett, David J.
    Downard, Alison J.
    ELECTROANALYSIS, 2011, 23 (02) : 417 - 423
  • [35] Selective Detection of Serotonin from the Interference by Ascorbic Acid and Uric Acid at Poly(thionine)-modified Glassy Carbon Electrode
    Ahammad, A. J. Saleh
    Nath, Narayan Chandra Deb
    Kim, Sunghyun
    Kim, Youngjun
    Lee, Jae-Joon
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2011, 32 (03): : 779 - 780
  • [36] Electrochemical detection of uric acid and xanthine in human urine using the Co/UiO-66 modified glassy carbon electrode
    Nguyen, Vo Thang
    Manh, Tran Duc
    Man, Nguyen Quang
    Thoa, Pham Thi Huyen
    Khieu, Dinh Quang
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2024, 54 (10) : 2361 - 2376
  • [37] Selective Determination of Dopamine and Uric Acid at Poly(acid red 176) Modified Glassy Carbon Electrode in the Presence of Ascorbic Acid
    Li, Xiao-bo
    Xu, Guang-ri
    Hu, Rui-yuan
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2013, 8 (02): : 1920 - 1927
  • [38] Glassy carbon electrode modified with an ordered mesoporous carbon/Ag nanoparticle nanocomposite for the selective detection of iodate
    Heidari, Hassan
    Habibi, Biuck
    Vaigan, Fatemeh Bonyadi
    ANALYTICAL METHODS, 2016, 8 (22) : 4406 - 4412
  • [39] Electrochemical Sensing of Uric Acid Using Glassy Carbon Modified with Multiwall Carbon Nanotubes Dispersed in Polyethylenimine
    Gutierrez, Alejandro
    Lozano, Maria L.
    Galicia, Laura
    Ferreyra, Nancy F.
    Rivas, Gustavo A.
    ELECTROANALYSIS, 2014, 26 (10) : 2191 - 2196
  • [40] Norepinephrine-modified glassy carbon electrode for the simultaneous determination of ascorbic acid and uric acid
    Zare, HR
    Memarzadeh, F
    Mazloum-Ardakani, M
    Namazian, M
    Golabi, SM
    ELECTROCHIMICA ACTA, 2005, 50 (16-17) : 3495 - 3502