Graphitized mesoporous carbon modified glassy carbon electrode for selective sensing of xanthine, hypoxanthine and uric acid

被引:60
|
作者
Thangaraj, Rajendiran [1 ]
Kumar, Annamalai Senthil [1 ]
机构
[1] Vellore Inst Technol Univ, Sch Adv Sci, Environm & Analyt Chem Div, Vellore 632014, Tamil Nadu, India
关键词
PERFORMANCE LIQUID-CHROMATOGRAPHY; PYROCHLORE MODIFIED ELECTRODE; ELECTROCATALYTIC OXIDATION; ASCORBIC-ACID; CAPILLARY-ELECTROPHORESIS; AMPEROMETRIC DETECTION; PURINE DERIVATIVES; PASTE ELECTRODE; SEPARATION; SENSOR;
D O I
10.1039/c2ay25029b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An efficient electrochemical sensor for simultaneous electrochemical sensing of three purine compounds, uric acid (UA), xanthine (X) and hypoxanthine (HX), using a graphitized mesoporous carbon (GMC) modified glassy carbon electrode (GCE/GMC) has been demonstrated in pH 7 phosphate buffer solution without any enzyme, prior to electrode activation, surfactant and sample pre-concentration step. Electrochemical investigation of the GCE/GMC with [Fe(CN)(6)](3-) indicates metallic conductor like surface features of the modified electrode. A diffusion controlled reaction mechanism was identified for the electro-oxidation of the three purine compounds with an electrocatalytic pathway, except for the UA, where it shows a surface area effect with a mixed-diffusion and adsorption controlled mechanism at higher scan rates (>70 mV s(-1)). Calculated full-width of the half maximum values for the simultaneous detection of the three purine compounds are 42, 53 and 64 mV respectively and these are the lowest values ever reported in the literature, suggesting effective electron-transfer behaviour of the modified electrode for the purine oxidations. Calibration plots for the simultaneous detection of the purine compounds were linear in the concentration range of 20-400 mu M, 20-320 mu M and 20-240 mu M for UA, X and HX with detection limit values of 110 nM, 388 nM, and 351 nM respectively. Selective sensing of the purine compounds in human blood-plasma, urine and fish samples was successfully demonstrated with recovery values similar to 100%.
引用
收藏
页码:2162 / 2171
页数:10
相关论文
共 50 条
  • [21] Determination of Xanthine in the Presence of Ascorbic and Uric Acids on the Glassy Carbon Electrode Modified with Poly(sulfosalicylic acid) Nanorods
    Jo, Suhee
    Jeong, Haesang
    Bae, Si Ra
    Jeon, Seungwon
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2008, 29 (12) : 2407 - 2412
  • [22] Electrocatalytic oxidation of uric acid at cysteine modified glassy carbon electrode
    Yan, Z
    Zhang, JR
    Fang, HQ
    ANALYTICAL LETTERS, 1999, 32 (02) : 223 - 234
  • [23] Comparison of electrochemical property between multiwalled carbon nanotubes and porous graphitized carbon monolith modified glassy carbon electrode for the simultaneous determination of ascorbic acid and uric acid
    Mukdasai, Siriboon
    Moore, Eric
    Glennon, Jeremy D.
    He, Xiaoyun
    Nesterenko, Ekaterina P.
    Nesterenko, Pavel N.
    Paull, Brett
    Pravda, Mila
    Srijaranai, Supalax
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2014, 731 : 53 - 59
  • [24] Xanthine oxidase modified glassy carbon paste electrode
    Anik, U
    Timur, S
    Wang, J
    Telefoncu, A
    ELECTROCHEMISTRY COMMUNICATIONS, 2004, 6 (09) : 913 - 916
  • [25] A Silver Hexacyanoferrate-Graphene Modified Glassy Carbon Electrode in Electrochemical Sensing of Uric Acid and Dopamine
    Zhang, Fenghua
    Li, Sue
    Zhang, Hua
    Li, Huaixiang
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (12): : 11181 - 11194
  • [26] Graphene Nanocomposite Modified Glassy Carbon Electrode: As a Sensing Platform for Simultaneous Determination of Methyldopa and Uric Acid
    Movlaee, Kaveh
    Ganjali, Mohammad Reza
    Aghazadeh, Mostafa
    Beitollahi, Hadi
    Hosseini, Morteza
    Shahabi, Shirin
    Norouzi, Parviz
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (01): : 305 - 315
  • [27] Glassy carbon electrode modified with poly(dibromofluorescein) for the selective determination of dopamine and uric acid in the presence of ascorbic acid
    Wang, Yan
    Xiao, Yan
    MICROCHIMICA ACTA, 2012, 178 (1-2) : 123 - 130
  • [28] Glassy carbon electrode modified with poly(dibromofluorescein) for the selective determination of dopamine and uric acid in the presence of ascorbic acid
    Yan Wang
    Yan Xiao
    Microchimica Acta, 2012, 178 : 123 - 130
  • [29] Selective Determination of Dopamine, Ascorbic Acid and Uric Acid at SDS-MWCNTs Modified Glassy Carbon Electrode
    Zhang, Jian
    Zhu, Zhixin
    Zhu, Jianling
    Li, Kechang
    Hua, Shucheng
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2014, 9 (03): : 1264 - 1272
  • [30] Highly Selective Differential Pulse Voltammetric Determination of Uric Acid using Modified Glassy Carbon Electrode
    Movlaee, Kaveh
    Norouzi, Parviz
    Beitollahi, Hadi
    Rezapour, Morteza
    Larijani, Bagher
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (04): : 3241 - 3251