Contraction behaviors of dental composite restorations - Finite element investigation with DIC validation

被引:35
|
作者
Chuang, Shu-Fen [1 ,2 ]
Chang, Chih-Han [3 ]
Chen, Terry Yuan-Fang [4 ]
机构
[1] Natl Cheng Kung Univ, Inst Oral Med, Coll Med & Hosp, 138 Sheng Li Rd, Tainan 70403, Taiwan
[2] Natl Cheng Kung Univ, Dept Stomatol, Coll Med & Hosp, Tainan 70403, Taiwan
[3] Natl Cheng Kung Univ, Inst Biomed Engn, Tainan 70403, Taiwan
[4] Natl Cheng Kung Univ, Ctr Micro Nano Sci & Technol, Dept Mech Engn, Tainan 70403, Taiwan
关键词
Dental restoration; Resin composite; Polymerization shrinkage; Digital image correlation; Finite element analysis; DIGITAL-IMAGE-CORRELATION; POLYMERIZATION SHRINKAGE STRAIN; ELASTIC-MODULUS; STRESS-ANALYSIS; C-FACTOR; RESIN; CONFIGURATION; MICROLEAKAGE; DEFORMATION; DIMENSIONS;
D O I
10.1016/j.jmbbm.2011.07.014
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The objective of this study was to examine the effects of cavity configuration on the polymerization shrinkage and stress of light-cured composite restorations by combining local strain measurement and a finite element analysis (FEA). Dental mesio-occlusodistal cavities of various widths and depths (each for 2 vs. 4 mm), representing different configuration factors, were prepared on extracted molars. The displacements of the bonded tooth cusps and cavity floors, caused by polymerization shrinkage of composite restorations, were assessed utilizing a digital-image-correlation (DIC) technique. The cervical marginal microleakage was investigated by examining the resin replicas of these restorations under SEM. The local material properties of the polymerized composite along the curing depth were defined by the nanoindentation test and applied in the subsequent PEA. In the FEA, four models were generated to correspond with the experimental restorations. In the DIC measurement results, the 4((omega)) x 4((D)) mm cavity presented the greatest values of inward displacements at the cusp and floor. The cavity depth, rather than the cavity width, was found to significantly correlate to the floor deformation, the location of shrinkage centers, and also the cervical microleakage ratio. The FEA simulation results showed that the 2((omega)) x 4((D)) mm cavity presented the maximal von Mises and principal stress located respectively on the cervical margins and cavity floor. Additional safety factor analysis showed a high risk of bond failure over the cavity floor in the 4-mm deep cavity. With the experimental validation, the simulation revealed that the cavity depth was significant to the formation of contraction stress and the incidence of interfacial debonding. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2138 / 2149
页数:12
相关论文
共 50 条
  • [41] A detailed finite element investigation of composite bolted joints with countersunk fasteners
    Stocchi, C.
    Robinson, P.
    Pinho, S. T.
    COMPOSITES PART A-APPLIED SCIENCE AND MANUFACTURING, 2013, 52 : 143 - 150
  • [42] Finite element investigation of the structural behaviour of deck slabs in composite bridges
    Zheng, Yu
    Robinson, Des
    Taylor, Su
    Cleland, David
    ENGINEERING STRUCTURES, 2009, 31 (08) : 1762 - 1776
  • [43] A numerical investigation for the optimisation of the behaviour of a composite EBF finite element model
    Vataman, A.
    Grecea, D.
    MODERN TECHNOLOGIES FOR THE 3RD MILLENNIUM, 2018, : 391 - 396
  • [44] FINITE ELEMENT ANALYSIS OF COMPOSITE REPAIRS WITH FULL-SCALE VALIDATION TESTING
    Sheets, Colton
    Rettew, Robert
    Alexander, Chris
    Iyer, Ashwin
    PROCEEDINGS OF THE 11TH INTERNATIONAL PIPELINE CONFERENCE, 2016, VOL 1, 2017,
  • [45] The Effects of Using Cements of Different Thicknesses and Amalgam Restorations with Different Young's Modulus Values on Stress on Dental Tissue: An Investigation Using Finite Element Analysis
    Gonder, Hakan Yasin
    Demirel, Mehmet Gokberkkaan
    Mohammadi, Reza
    Alkurt, Sinem
    Fidancioglu, Yasemin Derya
    Yuksel, Ibrahim Burak
    COATINGS, 2023, 13 (01)
  • [46] Development of patient-specific finite element model for study of composite dental implants
    Gupta, Vivek
    Garg, Anshika
    Tewari, Nitesh
    Srivastav, Sukeshana
    Chanda, Arnab
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2024, 10 (02)
  • [47] Three dimensional finite element analysis for direct fibre - Reinforced composite dental bridge
    Li, W
    Steven, GP
    Doube, CP
    COMPUTER METHODS IN BIOMECHANICS & BIOMEDICAL ENGINEERING - 2, 1998, : 713 - 720
  • [48] Finite-element analysis of deformation behaviors in random-whisker-reinforced composite
    Lee, W. J.
    Son, J. H.
    Kang, N. H.
    Park, I. M.
    Park, Y. H.
    SCRIPTA MATERIALIA, 2009, 61 (06) : 580 - 583
  • [49] Homogenized Finite Element Analysis on Effective Elastoplastic Mechanical Behaviors of Composite with Imperfect Interfaces
    Jiang, Wu-Gui
    Zhong, Ren-Zhi
    Qin, Qing H.
    Tong, Yong-Gang
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2014, 15 (12): : 23389 - 23407
  • [50] Finite element and in vitro study on biomechanical behavior of endodontically treated premolars restored with direct or indirect composite restorations
    Tatjana Maravić
    Allegra Comba
    Claudia Mazzitelli
    Luca Bartoletti
    Irene Balla
    Elisabetta di Pietro
    Uroš Josić
    Luigi Generali
    Darko Vasiljević
    Larisa Blažić
    Lorenzo Breschi
    Annalisa Mazzoni
    Scientific Reports, 12