Contraction behaviors of dental composite restorations - Finite element investigation with DIC validation

被引:35
|
作者
Chuang, Shu-Fen [1 ,2 ]
Chang, Chih-Han [3 ]
Chen, Terry Yuan-Fang [4 ]
机构
[1] Natl Cheng Kung Univ, Inst Oral Med, Coll Med & Hosp, 138 Sheng Li Rd, Tainan 70403, Taiwan
[2] Natl Cheng Kung Univ, Dept Stomatol, Coll Med & Hosp, Tainan 70403, Taiwan
[3] Natl Cheng Kung Univ, Inst Biomed Engn, Tainan 70403, Taiwan
[4] Natl Cheng Kung Univ, Ctr Micro Nano Sci & Technol, Dept Mech Engn, Tainan 70403, Taiwan
关键词
Dental restoration; Resin composite; Polymerization shrinkage; Digital image correlation; Finite element analysis; DIGITAL-IMAGE-CORRELATION; POLYMERIZATION SHRINKAGE STRAIN; ELASTIC-MODULUS; STRESS-ANALYSIS; C-FACTOR; RESIN; CONFIGURATION; MICROLEAKAGE; DEFORMATION; DIMENSIONS;
D O I
10.1016/j.jmbbm.2011.07.014
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The objective of this study was to examine the effects of cavity configuration on the polymerization shrinkage and stress of light-cured composite restorations by combining local strain measurement and a finite element analysis (FEA). Dental mesio-occlusodistal cavities of various widths and depths (each for 2 vs. 4 mm), representing different configuration factors, were prepared on extracted molars. The displacements of the bonded tooth cusps and cavity floors, caused by polymerization shrinkage of composite restorations, were assessed utilizing a digital-image-correlation (DIC) technique. The cervical marginal microleakage was investigated by examining the resin replicas of these restorations under SEM. The local material properties of the polymerized composite along the curing depth were defined by the nanoindentation test and applied in the subsequent PEA. In the FEA, four models were generated to correspond with the experimental restorations. In the DIC measurement results, the 4((omega)) x 4((D)) mm cavity presented the greatest values of inward displacements at the cusp and floor. The cavity depth, rather than the cavity width, was found to significantly correlate to the floor deformation, the location of shrinkage centers, and also the cervical microleakage ratio. The FEA simulation results showed that the 2((omega)) x 4((D)) mm cavity presented the maximal von Mises and principal stress located respectively on the cervical margins and cavity floor. Additional safety factor analysis showed a high risk of bond failure over the cavity floor in the 4-mm deep cavity. With the experimental validation, the simulation revealed that the cavity depth was significant to the formation of contraction stress and the incidence of interfacial debonding. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2138 / 2149
页数:12
相关论文
共 50 条
  • [31] Nanoscale mechanical analysis of dental filling composite and its finite element modelling
    Eichlerova, R.
    Lukes, J.
    Sepitka, J.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2011, 14 : 261 - 262
  • [32] Biomechanical performance of resin composite on dental tissue restoration: A finite element analysis
    Ouldyerou, Abdelhak
    Mehboob, Hassan
    Mehboob, Ali
    Merdji, Ali
    Aminallah, Laid
    Mukdadi, Osama M.
    Barsoum, Imad
    Junaedi, Harri
    PLOS ONE, 2023, 18 (12):
  • [33] Modeling dental composite shrinkage by digital image correlation and finite element methods
    Chen, Terry Yuan-Fang
    Huang, Pin-Sheng
    Chuang, Shu-Fen
    OPTICS AND LASERS IN ENGINEERING, 2014, 61 : 23 - 30
  • [34] New Subperiosteal Dental Implant Design with Finite Element Analysis and Mechanical Validation: A Design Validation Study
    Vanaclocha, Vicente
    Atienza, Carlos
    Vanaclocha, Amparo
    Penuelas, Andres
    Gomez-Herrero, Juan
    Perez-Carrio, Francisco
    Diego-Leyda, Jose Antonio
    Saiz-Sapena, Nieves
    Vanaclocha, Leyre
    MATERIALS, 2025, 18 (03)
  • [35] Finite Element Model of the Knee for Investigation of Injury Mechanisms: Development and Validation
    Kiapour, Ali
    Kiapour, Ata M.
    Kaul, Vikas
    Quatman, Carmen E.
    Wordeman, Samuel C.
    Hewett, Timothy E.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2014, 136 (01):
  • [36] Comparison of Bulk Polymeric Resin Composite and Hybrid Glass Ionomer Cement in Adhesive Class I Dental Restorations: A 3D Finite Element Analysis
    di Lauro, Alessandro E.
    Ciaramella, Stefano
    Tribst, Joao P. Mendes
    Aliberti, Angelo
    Ausiello, Pietro
    POLYMERS, 2024, 16 (17)
  • [37] 3D finite element analysis on esthetic indirect dental restorations under thermal and mechanical loading
    Cornacchia, Tulimar P. M.
    Las Casas, Estevam B.
    Cimini, Carlos Alberto, Jr.
    Peixoto, Rodrigo G.
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2010, 48 (11) : 1107 - 1113
  • [38] 3D finite element analysis on esthetic indirect dental restorations under thermal and mechanical loading
    Tulimar P. M. Cornacchia
    Estevam B. Las Casas
    Carlos Alberto Cimini
    Rodrigo G. Peixoto
    Medical & Biological Engineering & Computing, 2010, 48 : 1107 - 1113
  • [39] Numerical investigation of a finite element abdominal wall model during breathing and muscular contraction
    Jourdan, Arthur
    Dhume, Rohit
    Guerin, Elisabeth
    Siegel, Alice
    Le Ruyet, Anicet
    Palmer, Mark
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2024, 244
  • [40] Investigation of the role of dental ceramic core material using finite element analysis
    Proos, K
    Swain, M
    Ironside, J
    Steven, G
    BIOCERAMICS 15, 2003, 240-2 : 871 - 874