Intramedullary reaming for press-fit fixation of a humeral component removes cortical bone asymmetrically

被引:13
|
作者
Lee, Michael [1 ]
Chebli, Caroline [1 ]
Mounce, Doug [1 ]
Bertelsen, Alexander [1 ]
Richardson, Michael [2 ]
Matsen, Frederick, III [1 ]
机构
[1] Univ Washington, Med Ctr, Dept Orthopaed & Sports Med, Seattle, WA 98195 USA
[2] Univ Washington, Med Ctr, Dept Radiol, Seattle, WA 98195 USA
关键词
D O I
10.1016/j.jse.2007.03.032
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Periprosthetic humeral fractures are major complications of shoulder arthroplasty Bone removal during surgical reaming is a risk factor for these fractures. Although it is recognized that the endosteal surface of the humerus is asymmetrical whereas the reamers are symmetrical, to our knowledge, the effect of cylindrical reaming on the pattern of cortical bone removal during reaming has not been previously studied. The medullary canals of 10 cadaveric humeri (mean age, 73 years) were reamed in a manner similar to that used during humeral arthroplasty. Cortical dimensions were obtained from computed tomography scans before and after reaming. In unreamed humeri, the anterior-posterior endocortical diameter was 20% smaller than the medial-lateral diameter. The average medial-lateral diameter (15.6 +/- 2.3 mm) was significantly greater than the anterior-posterior diameter (12.5 +/- 1.9 mm) at 13 cm distal to the tuberosity (P < .00005). Successive cylindrical reaming preferentially thinned the anterior and posterior cortices. This bone loss would not be apparent on anterior-posterior radiographs. Intramedullary reaming to obtain substantial cortical contact asymmetrically removes cortical bone in a manner that may increase the risk of periprosthetic fracture.
引用
收藏
页码:150 / 155
页数:6
相关论文
共 50 条
  • [41] Tibial press-fit fixation of the hamstring tendons for ACL-reconstruction
    Jagodzinski, M.
    Scheunemann, K.
    Knobloch, K.
    Albrecht, K.
    Krettek, C.
    Hurschler, C.
    Zeichen, J.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2006, 14 (12) : 1281 - 1287
  • [42] Biomechanical analysis of press-fit fixation of anterior cruciate ligament transplants
    Jagodzinski, M.
    Ettinger, M.
    Haasper, C.
    Hankemeier, S.
    Breitmeier, D.
    Hurschler, C.
    Krettek, C.
    UNFALLCHIRURG, 2010, 113 (07): : 532 - 539
  • [43] BIOLOGIC FIXATION OF A PRESS-FIT TITANIUM HIP-JOINT ENDOPROSTHESIS
    ZWEYMULLER, KA
    LINTNER, FK
    SEMLITSCH, MF
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1988, (235) : 195 - 206
  • [44] Computational assessment of press-fit acetabular implant fixation: the effect of implant design, interference fit, bone quality, and frictional properties
    Janssen, D.
    Zwartele, R. E.
    Doets, H. C.
    Verdonschot, N.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2010, 224 (H1) : 67 - 75
  • [45] Reconstruction of the Acetabulum with Structured Bone Graft in Press-Fit Technique
    Halder, Andreas
    Beier, Alexander
    Neumann, Wolfram
    OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2010, 22 (03): : 232 - 240
  • [46] Periacetabular Cortical and Cancellous Bone Mineral Density Loss After Press-Fit Cup Fixation A Prospective 7-Year Follow-Up
    Schmidt, Rainer
    Kress, Alexander Michael
    Nowak, Melanie
    Forst, Raimund
    Nowak, Tobias Eckhard
    Mueller, Lutz Arne
    JOURNAL OF ARTHROPLASTY, 2012, 27 (07): : 1358 - 1363
  • [47] The effect of bone quality on the intramedullary fixation of proximal humeral fractures
    Rajesh, MB
    BONE, 2003, 32 (05) : S165 - S165
  • [48] Tensile properties of an anterior cruciate ligament graft after bone-patellar tendon-bone press-fit fixation
    Musahl, V
    Abramowitch, SD
    Gabriel, MT
    Debski, RE
    Hertel, P
    Fu, FH
    Woo, SLY
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2003, 11 (02) : 68 - 74
  • [49] Beta-tricalcium phosphate plugs for press-fit fixation in ACL reconstruction - A mechanical analysis in bovine bone
    Mayr, Hermann O.
    Hube, Robert
    Bernstein, Anke
    Seibt, Alexander B.
    Hein, Werner
    von Eisenhart-Rothe, Ruediger
    KNEE, 2007, 14 (03): : 239 - 244
  • [50] Implant-free press-fit fixation for bone–patellar tendon–bone ACL reconstruction: 10-year results
    Gernot Felmet
    Archives of Orthopaedic and Trauma Surgery, 2010, 130 : 985 - 992