Intramedullary reaming for press-fit fixation of a humeral component removes cortical bone asymmetrically

被引:13
|
作者
Lee, Michael [1 ]
Chebli, Caroline [1 ]
Mounce, Doug [1 ]
Bertelsen, Alexander [1 ]
Richardson, Michael [2 ]
Matsen, Frederick, III [1 ]
机构
[1] Univ Washington, Med Ctr, Dept Orthopaed & Sports Med, Seattle, WA 98195 USA
[2] Univ Washington, Med Ctr, Dept Radiol, Seattle, WA 98195 USA
关键词
D O I
10.1016/j.jse.2007.03.032
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Periprosthetic humeral fractures are major complications of shoulder arthroplasty Bone removal during surgical reaming is a risk factor for these fractures. Although it is recognized that the endosteal surface of the humerus is asymmetrical whereas the reamers are symmetrical, to our knowledge, the effect of cylindrical reaming on the pattern of cortical bone removal during reaming has not been previously studied. The medullary canals of 10 cadaveric humeri (mean age, 73 years) were reamed in a manner similar to that used during humeral arthroplasty. Cortical dimensions were obtained from computed tomography scans before and after reaming. In unreamed humeri, the anterior-posterior endocortical diameter was 20% smaller than the medial-lateral diameter. The average medial-lateral diameter (15.6 +/- 2.3 mm) was significantly greater than the anterior-posterior diameter (12.5 +/- 1.9 mm) at 13 cm distal to the tuberosity (P < .00005). Successive cylindrical reaming preferentially thinned the anterior and posterior cortices. This bone loss would not be apparent on anterior-posterior radiographs. Intramedullary reaming to obtain substantial cortical contact asymmetrically removes cortical bone in a manner that may increase the risk of periprosthetic fracture.
引用
收藏
页码:150 / 155
页数:6
相关论文
共 50 条
  • [31] Response to La Banca et al regarding "On the concerning early failure of a short stem press-fit humeral component"
    Nicholson, Gregory
    Pourzal, Robin
    Garrigues, Grant E.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2025, 34 (03) : e178 - e178
  • [32] Knee arthrodesis with a press-fit modular intramedullary nail without bone-on-bone fusion after an infected revision TKA
    Iacono, Francesco
    Bruni, Danilo
    Lo Presti, Mirco
    Raspugli, Giovanni
    Bondi, Alice
    Sharma, Bharat
    Marcacci, Maurilio
    KNEE, 2012, 19 (05): : 555 - 559
  • [33] Characterization of bone-implant fixation using modal analysis: Application to a press-fit implant model
    Swider, P.
    Guerin, G.
    Baas, Joergen
    Soballe, Kjeld
    Bechtold, Joan E.
    JOURNAL OF BIOMECHANICS, 2009, 42 (11) : 1643 - 1649
  • [34] Tibial Press-Fit Fixation Technique in Anterior Cruciate Ligament Reconstruction
    Kocabey, Yavuz
    Yildirim, Cem
    Erden, Tunay
    Kaya, Alper
    ARTHROSCOPY TECHNIQUES, 2023, 12 (05): : E737 - E743
  • [35] INTRAMEDULLARY REAMING AND NAILING - ITS EARLY EFFECTS ON CORTICAL BONE VASCULARIZATION
    OLERUD, S
    STROMBERG, L
    ORTHOPEDICS, 1986, 9 (09) : 1204 - 1208
  • [36] Tibial press-fit fixation of the hamstring tendons for ACL-reconstruction
    M. Jagodzinski
    K. Scheunemann
    K. Knobloch
    K. Albrecht
    C. Krettek
    C. Hurschler
    J. Zeichen
    Knee Surgery, Sports Traumatology, Arthroscopy, 2006, 14 : 1281 - 1287
  • [37] Press-fit fixation in reconstruction of anterior cruciate ligament, using bone-patellar tendon-bone graft
    Al-Husseiny, M
    Batterjee, K
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2004, 12 (02) : 104 - 109
  • [38] The biomechanical strength of a hardware-free femoral press-fit method for ACL bone–tendon–bone graft fixation
    M. P. Arnold
    L. D. Burger
    D. Wirz
    B. Goepfert
    M. T. Hirschmann
    Knee Surgery, Sports Traumatology, Arthroscopy, 2017, 25 (4) : 1234 - 1240
  • [39] Biomechanical evaluation of press-fit femoral fixation technique in ACL reconstruction
    Attila Pavlik
    Péter Hidas
    Tibor Czigány
    István Berkes
    Knee Surgery, Sports Traumatology, Arthroscopy, 2004, 12 : 528 - 533
  • [40] Biomechanical evaluation of press-fit femoral fixation technique in ACL reconstruction
    Pavlik, A
    Hidas, P
    Czigány, T
    Berkes, I
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2004, 12 (06) : 528 - 533