Comparison of Diffusion-Weighted Imaging in the Human Brain Using Readout-Segmented EPI and PROPELLER Turbo Spin Echo With Single-Shot EPI at 7 T MRI

被引:29
|
作者
Kida, Ikuhiro [1 ,2 ]
Ueguchi, Takashi [1 ,2 ]
Matsuoka, Yuichiro [1 ,2 ]
Zhou, Kun [3 ]
Stemmer, Alto [4 ]
Porter, David [5 ]
机构
[1] Natl Inst Informat & Commun Technol, Ctr Informat & Neural Networks, 1-4 Yamadaoka, Suita, Osaka 5650871, Japan
[2] Osaka Univ, Grad Sch Frontier Biosci, Osaka, Japan
[3] Siemens Shenzhen Magnet Resonance Ltd, Shenzhen, Peoples R China
[4] Siemens Healthcare GmbH, Erlangen, Germany
[5] Fraunhofer Inst Med Image Comp MEVIS, Bremen, Germany
关键词
diffusion-weighted imaging; 7; T; EPI; BLADE; RESOLVE; ADC; brain; PROPELLER; readout-segmented EPI; REDUCTION; ISCHEMIA;
D O I
10.1097/RLI.0000000000000248
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives The purpose of the present study was to compare periodically rotated overlapping parallel lines with enhanced reconstruction-type turbo spin echo diffusion-weighted imaging (pTSE-DWI) and readout-segmented echo planar imaging (rsEPI-DWI) with single-shot echo planar imaging (ssEPI-DWI) in a 7 T human MR system. We evaluated the signal-to-noise ratio (SNR), image distortion, and apparent diffusion coefficient values in the human brain. Materials and Methods Six healthy volunteers were included in this study. The study protocol was approved by our institutional review board. All measurements were performed at 7 T using pTSE-DWI, rsEPI-DWI, and ssEPI-DWI sequences. The spatial resolution was 1.2 x 1.2 mm(2) in-plane with a 3-mm slice thickness. Signal-to-noise ratio was measured using 2 scans. Results The ssEPI-DWI sequence showed significant image blurring, whereas pTSE-DWI and rsEPI-DWI sequences demonstrated high image quality with low geometrical distortion compared with reference T2-weighted, turbo spin echo images. Signal loss in ventral regions near the air-filled paranasal sinus/nasal cavity was found in ssEPI-DWI and rsEPI-DWI but not pTSE-DWI. The apparent diffusion coefficient values for ssEPI-DWI were 824 17 x 10(-6) and 749 +/- 25 x 10(-6) mm(2)/s in the gray matter and white matter, respectively; the values obtained for pTSE-DWI were 798 +/- 21 x 10(-6) and 865 +/- 40 x 10(-6) mm(2)/s; and the values obtained for rsEPI-DWI were 730 +/- 12 x 10(-6) and 722 +/- 25 x 10(-6) mm(2)/s. The pTSE-DWI images showed no additional distortion comparison to the T2-weighted images, but had a lower SNR than ssEPI-DWI and rsEPI-DWI. The rsEPI-DWI sequence provided high-quality images with minor distortion and a similar SNR to ssEPI-DWI. Conclusions Our results suggest that the benefits of the rsEPI-DWI and pTSE-DWI sequences, in terms of SNR, image quality, and image distortion, appear to outweigh those of ssEPI-DWI. Thus, pTSE-DWI and rsEPI-DWI at 7 T have great potential use for clinical diagnoses. However, it is noteworthy that both sequences are limited by the scan time required. In addition, pTSE-DWI has limitations on the number of slices due to specific absorption rate. Overall, rsEPI-DWI is a favorable imaging sequence, taking into account the SNR and image quality at 7 T.
引用
收藏
页码:435 / 439
页数:5
相关论文
共 50 条
  • [21] Comparison of DWI Methods in the Pediatric Brain: PROPELLER Turbo Spin-Echo Imaging Versus Readout-Segmented Echo-Planar Imaging Versus Single-Shot Echo-Planar Imaging
    Kim, Tae-Hyung
    Baek, Moon-Young
    Park, Ji Eun
    Ryu, Young Jin
    Cheon, Jung-Eun
    Kim, In-One
    Choi, Young Hun
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 210 (06) : 1352 - 1358
  • [22] Comparing the clinical utility of single-shot, readout-segmented and zoomit echo-planar imaging in diffusion-weighted imaging of the kidney at 3 T
    Liu, Wenguang
    Liu, Hui
    Xie, Simin
    Masokano, Ismail Bilal
    Bai, Yu
    Wang, Xiao
    Zhong, Linhui
    Wu, Yi
    Nie, Jilin
    Zhou, Gaofeng
    Pei, Yigang
    Li, Wenzheng
    [J]. SCIENTIFIC REPORTS, 2022, 12 (01)
  • [23] Comparing the clinical utility of single-shot, readout-segmented and zoomit echo-planar imaging in diffusion-weighted imaging of the kidney at 3 T
    Wenguang Liu
    Hui Liu
    Simin xie
    Ismail Bilal Masokano
    Yu Bai
    Xiao Wang
    Linhui Zhong
    Yi Wu
    Jilin Nie
    Gaofeng Zhou
    Yigang Pei
    Wenzheng Li
    [J]. Scientific Reports, 12
  • [24] Readout-segmented echo-planar imaging improves the image quality of diffusion-weighted MR imaging in rectal cancer: Comparison with single-shot echo-planar diffusion-weighted sequences
    Xia, Chun-chao
    Liu, Xi
    Peng, Wan-lin
    Li, Lei
    Zhang, Jin-ge
    Meng, Wen-jian
    Deng, Xiang-bing
    Zuo, Pan-li
    Li, Zhen-lin
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (10) : 1818 - 1823
  • [25] Readout-segmented echo-planar imaging in diffusion-weighted MR imaging of acute infarction of the brainstem and posterior fossa: comparison of single-shot echo-planar diffusion-weighted sequences
    Byeon, Jonghyun
    Kim, Jee Young
    Cho, A-Hyun
    [J]. CLINICAL IMAGING, 2015, 39 (05) : 765 - 769
  • [26] Readout-Segmented Echo-Planar Imaging in Diffusion-Weighted MR Imaging in Breast Cancer: Comparison with Single-Shot Echo-Planar Imaging in Image Quality
    Kim, Yun Ju
    Kim, Sung Hun
    Kang, Bong Joo
    Park, Chang Suk
    Kim, Hyeon Sook
    Son, Yo Han
    Porter, David Andrew
    Song, Byung Joo
    [J]. KOREAN JOURNAL OF RADIOLOGY, 2014, 15 (04) : 403 - 410
  • [27] Diffusion-weighted imaging (DWI) in MR mammography (MRM): clinical comparison of echo planar imaging (EPI) and half-Fourier single-shot turbo spin echo (HASTE) diffusion techniques
    Baltzer, P. A. T.
    Renz, D. M.
    Herrmann, K. -H.
    Dietzel, M.
    Krumbein, I.
    Gajda, M.
    Camara, O.
    Reichenbach, J. R.
    Kaiser, W. A.
    [J]. EUROPEAN RADIOLOGY, 2009, 19 (07) : 1612 - 1620
  • [28] Diffusion-weighted imaging (DWI) in MR mammography (MRM): clinical comparison of echo planar imaging (EPI) and half-Fourier single-shot turbo spin echo (HASTE) diffusion techniques
    P. A. T. Baltzer
    D. M. Renz
    K.-H. Herrmann
    M. Dietzel
    I. Krumbein
    M. Gajda
    O. Camara
    J. R. Reichenbach
    W. A. Kaiser
    [J]. European Radiology, 2009, 19 : 1612 - 1620
  • [29] Diffusion tensor imaging of human Achilles tendon by stimulated echo readout-segmented EPI (ste-RS-EPI)
    Wengler, Kenneth
    Tank, Dharmesh
    Fukuda, Takeshi
    Paci, James M.
    Huang, Mingqian
    Schweitzer, Mark E.
    He, Xiang
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (06) : 2464 - 2474
  • [30] Scan time reduction for readout-segmented EPI using simultaneous multislice acceleration: Diffusion-weighted imaging at 3 and 7 Tesla
    Frost, Robert
    Jezzard, Peter
    Douaud, Gwenaelle
    Clare, Stuart
    Porter, David A.
    Miller, Karla L.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2015, 74 (01) : 136 - 149