共 50 条
Diffusion tensor imaging of human Achilles tendon by stimulated echo readout-segmented EPI (ste-RS-EPI)
被引:22
|作者:
Wengler, Kenneth
[1
]
Tank, Dharmesh
[2
]
Fukuda, Takeshi
[2
]
Paci, James M.
[3
]
Huang, Mingqian
[2
]
Schweitzer, Mark E.
[2
]
He, Xiang
[2
]
机构:
[1] SUNY Stony Brook, Dept Biomed Engn, Stony Brook, NY 11794 USA
[2] SUNY Stony Brook, Dept Radiol, Stony Brook, NY 11794 USA
[3] SUNY Stony Brook, Dept Orthopaed Surg, Stony Brook, NY 11794 USA
关键词:
Achilles tendon;
diffusion tensor imaging;
readout-segmented EPI;
stimulated echo;
tendinopathy;
TIME-DEPENDENT DIFFUSION;
IN-VIVO;
MAGNETIC-RESONANCE;
FRACTIONAL ANISOTROPY;
T2-ASTERISK ANALYSIS;
COLLAGEN STRUCTURE;
PATELLAR TENDON;
WHITE-MATTER;
CELL-SIZE;
SPECTROSCOPY;
D O I:
10.1002/mrm.27220
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
Purpose: Healing, regeneration, and remodeling of the injured Achilles tendon are associated with notable changes in tendon architecture. However, assessing Achilles microstructural properties with conventional diffusion tension imaging (DTI) remains a challenge because of very short T-2/T-2(chi) values of the tendon. Hence, the objective of this study was to develop a novel Achilles tendon DTI protocol for a non-invasive investigation of the changes of microstructural integrity in tendinopathy. Methods: A novel stimulated echo readout-segmented EPI (ste-RS-EPI) DTI sequence was proposed to achieve a TE of similar to 14-20 ms for typical b-values of 400-800 s/mm(2) on clinical 3T MRI scanners. To further boost tendon MR signal, the Achilles was positioned at the magic angle (similar to 55 degrees) with respect to the scanner B-0 field. The sensitivity of the developed protocol was evaluated in 19 healthy participants and 6 patients with clinically confirmed tendinopathy. Results: Compared to spin echo RS-EPI DTI protocol, ste-RS-EPI provided an similar to 100-200% increase in Achilles MR signal. Tendinopathic Achilles demonstrated a high degree of microstructural disruption based on DTI tractography analysis, with significantly lower (P<0.05) axial diffusivity (1.20 +/- 0.19 vs. 1.39 +/- 0.10x10(-3) mm(2)/s), radial diffusivity (0.72 +/- 0.11 vs. 0.81 +/- 0.08x10(-3) mm(2)/s), and mean diffusivity (0.87 +/- 0.14 vs. 1.00 +/- 0.07x10(-3) mm(2)/s), but no significant difference in fractional anisotropy (0.38 +/- 0.04 vs. 0.38 +/- 0.05; P=0.86). Conclusion: Achilles tendon ste-RS-EPI DTI can non-invasively detect the tendinopathy-induced changes to microstructural integrity, consistent with the disruption of collagen arrangement and increased cellularity. This study demonstrated the robustness and sensitivity of the proposed protocol in Achilles tendinopathy.
引用
收藏
页码:2464 / 2474
页数:11
相关论文