The error of neglecting natural convection in high temperature vertical shell-and-tube latent heat thermal energy storage systems

被引:28
|
作者
Tehrani, S. Saeed Mostafavi [1 ]
Diarce, Gonzalo [2 ]
Taylor, Robert A. [1 ]
机构
[1] Univ New South Wales, Sch Mech & Mfg Engn, Sydney, NSW 2052, Australia
[2] Univ Basque Country UPV EHU, Escuela Ingn Bilbao, Dept Maquinas y Motores Term, ENEDI Res Grp, Rafael Moreno Pitxitxi 2, Bilbao 48013, Spain
关键词
High temperature; Latent heat; Phase change material (PCM); Natural convection; Error correlation; Shell-and-tube; PHASE-CHANGE MATERIALS; TRANSIENT-BEHAVIOR ANALYSIS; NUMERICAL-ANALYSIS; PERFORMANCE; SOLIDIFICATION; DESIGN; SIMULATION; OPTIMIZATION; PARAMETERS; PARAFFIN;
D O I
10.1016/j.solener.2018.09.048
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
There is little understanding of the relative importance of natural convection when designing latent heat thermal energy storage (LHTES) systems based on geometric parameters and/or phase change material (PCM) properties. For high temperature shell-and-tube LHTES systems, this study aims: (i) to determine the error of ignoring natural convection, and (ii) to quantify this error for different geometric parameters and PCM properties. In particular, the study defines the circumstances under which natural convection is important and the error of choosing a 'conduction-only modelling approach'. To do so, the performance of LHTES systems with nine geometric aspect ratios and three commercial PCMs (of different melting points) were analyzed by means of a validated CFD model. The results showed that the error is a function of the process under analysis (melting or solidification) and the ratio of stored/delivered energy divided by the maximum capacity of PCM (i.e. its effectiveness). Geometry also plays a critical role in the relative importance of natural convection. The study demonstrates that a specific system geometry (i.e. a dimensionless number defined based on the inner and outer radius as well as the length of shell-and-tube geometry: S = R-2 - r(0)(2)/2r(0)L) can be used to determine the relevance of natural convection. It was found that regardless of PCM type, the error is of neglecting natural congestion is small if S < 0.005. For S > 0.005, the error depends on the following non-dimensional groups: r(0)/L, Ra, Ste, and Bi. As might be expected, the Rayleigh number was found to be the most influential group. Notably, a critical Rayleigh number value (8 x 10(5)) was found, below which the error of neglecting natural convection is < 1%. Finally, two correlations were developed in order to quantify the error achieved - one for melting and another for solidification.
引用
收藏
页码:489 / 501
页数:13
相关论文
共 50 条
  • [21] Effect of perforated fins on the heat-transfer performance of vertical shell-and-tube latent heat energy storage unit
    Li, Hongyang
    Hu, Chengzhi
    He, Yichuan
    Tang, Dawei
    Wang, Kuiming
    Huang, Wenguo
    JOURNAL OF ENERGY STORAGE, 2021, 39 (39):
  • [22] Experimental study on the melting and solidification behavior of erythritol in a vertical shell-and-tube latent heat thermal storage unit
    Wang, Yifei
    Wang, Liang
    Xie, Ningning
    Lin, Xipeng
    Chen, Haisheng
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2016, 99 : 770 - 781
  • [23] Numerical investigation of a shell-and-tube latent heat thermal energy storage system for urban heating network
    Lamrani, Bilal
    Kousksou, Tarik
    JOURNAL OF ENERGY STORAGE, 2021, 43
  • [24] NUMERICAL-SIMULATION OF A SHELL-AND-TUBE LATENT-HEAT THERMAL-ENERGY STORAGE UNIT
    LACROIX, M
    SOLAR ENERGY, 1993, 50 (04) : 357 - 367
  • [25] Simplified model for estimating performance of latent heat thermal energy storage of a shell-and-tube type unit
    Nakaso, K
    Nogami, S
    Takahashi, N
    Hamada, Y
    Fukai, J
    KAGAKU KOGAKU RONBUNSHU, 2004, 30 (04) : 474 - 479
  • [26] Economic evaluation of shell-and-tube latent heat thermal energy storage for concentrating solar power applications
    Bai, F.
    Wang, Y.
    Wang, Z.
    Sun, Y.
    Beath, A.
    INTERNATIONAL CONFERENCE ON CONCENTRATING SOLAR POWER AND CHEMICAL ENERGY SYSTEMS, SOLARPACES 2014, 2015, 69 : 737 - 747
  • [27] Numerical investigations of the effect of the flip method on charging/ discharging performance of a vertical shell-and-tube latent heat thermal energy storage unit
    Dai, Hui
    Zhou, Shaobin
    Niu, Pingping
    Wang, Wenlong
    Jiang, Jianguo
    He, Suoying
    Gao, Ming
    JOURNAL OF ENERGY STORAGE, 2023, 73
  • [28] Effects of shell modifications and operational parameters on melting uniformity of a vertical multi-section shell-and-tube latent heat thermal energy storage unit
    Chen, Lanxin
    Fan, Aiwu
    JOURNAL OF ENERGY STORAGE, 2022, 55
  • [29] Enhancing Heat Transfer and Energy Storage Performance of Shell-and-Tube Latent Heat Thermal Energy Storage Unit with Unequal-Length Fins
    Yangyang Wu
    Dong Li
    Ruitong Yang
    Arıcı Müslüm
    Changyu Liu
    Journal of Thermal Science, 2023, 32 : 2018 - 2031
  • [30] Enhancing Heat Transfer and Energy Storage Performance of Shell-and-Tube Latent Heat Thermal Energy Storage Unit with Unequal-Length Fins
    Wu Yangyang
    Li Dong
    Yang Ruitong
    Muslum, Arici
    Liu Changyu
    JOURNAL OF THERMAL SCIENCE, 2023, 32 (06) : 2018 - 2031