Standardization of Ga-68 by coincidence measurements, liquid scintillation counting and 4πγ counting

被引:4
|
作者
Roteta, Miguel
Peyres, Virginia
Rodriguez Barquero, Leonor
Garcia-Torano, Eduardo
Arenillas, Pablo
Balpardo, Christian
Rodrigues, Dario
Llovera, Roberto
机构
关键词
Ga-68; Ge-68; Radionuclide standardization; IMPLEMENTATION; GE-68/GA-68; EFFICIENCY; EMITTERS;
D O I
10.1016/j.apradiso.2012.02.066
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The radionuclide Ga-68 is one of the few positron emitters that can be prepared in-house without the use of a cyclotron. It disintegrates to the ground state of Zn-68 partially by positron emission (89.1%) with a maximum energy of 1899.1 keV, and partially by electron capture (10.9%). This nuclide has been standardized in the frame of a cooperation project between the Radionuclide Metrology laboratories from CIEMAT (Spain) and CNEA (Argentina). Measurements involved several techniques: 4 pi beta-gamma coincidences, integral gamma counting and Liquid Scintillation Counting using the triple to double coincidence ratio and the CIEMAT/NIST methods. Given the short half-life of the radionuclide assayed, a direct comparison between results from both laboratories was excluded and a comparison of experimental efficiencies of similar Nal detectors was used instead. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2006 / 2011
页数:6
相关论文
共 50 条
  • [31] Cerenkov counting as a complement to liquid scintillation counting
    Scarpitta, SC
    Fisenne, IM
    APPLIED RADIATION AND ISOTOPES, 1996, 47 (08) : 795 - 800
  • [32] SPECIAL PROBLEMS INVOLVED IN LIQUID SCINTILLATION COUNTING - STANDARDIZATION OF Y-87 AND GA-67
    STEYN, J
    NUCLEAR INSTRUMENTS & METHODS, 1973, 112 (1-2): : 137 - 141
  • [34] Digital coincidence acquisition applied to portable β liquid scintillation counting device
    Ren Zhongguo
    Hu Bitao
    Zhao Zhiping
    Li Dongcang
    NUCLEAR SCIENCE AND TECHNIQUES, 2013, 24 (03)
  • [35] Digital coincidence acquisition applied to portable β liquid scintillation counting device
    REN Zhongguo
    HU Bitao
    ZHAO Zhiping
    LI Dongcang
    Nuclear Science and Techniques, 2013, 24 (03) : 47 - 51
  • [36] Standardization of 90Y solution by mean of a Cherenkov counting in comparison with a liquid scintillation counting technique
    Ziemek, Tomasz
    Lech, Edyta
    Tyminski, Zbigniew
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2022, 331 (08) : 3327 - 3333
  • [37] Standardization of 90Y solution by mean of a Cherenkov counting in comparison with a liquid scintillation counting technique
    Tomasz Ziemek
    Edyta Lech
    Zbigniew Tymiński
    Journal of Radioanalytical and Nuclear Chemistry, 2022, 331 : 3327 - 3333
  • [38] Accurate activity measurement of Lu-177 by the liquid scintillation 4πβ-γ coincidence counting technique
    Simpson, B. R. S.
    van Staden, M. J.
    Lubbe, J.
    van Wyngaardt, W. M.
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (09) : 2209 - 2214
  • [39] Liquid-scintillation counting techniques for the standardization of radionuclides used in therapy
    Coursey, B.M.
    Calhoum, J.M.
    Cessna, J.
    Golas, D.B.
    Shima, F.J.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1994, A339 (1-2) : 26 - 30
  • [40] LIQUID SCINTILLATION-COUNTING FOR THE STANDARDIZATION OF BETA-PARTICLE EMITTERS
    SONG, L
    WU, XZ
    WANG, ZE
    NUCLEAR INSTRUMENTS & METHODS, 1980, 175 (2-3): : 503 - 508