Computer-assisted diagnostic procedure for multislice computed tomography for assessment of the pulmonary arterial circulation

被引:0
|
作者
Malich, A. [1 ]
Hentrich, D.
Hansch, A. [2 ]
Boettcher, J.
Teichgraeber, U. [2 ]
机构
[1] Sudharz Krankenhaus Nordhausen, Inst Radiol, D-99734 Nordhausen, Germany
[2] Univ Jena, Zentrum Radiol, D-6900 Jena, Germany
来源
RADIOLOGE | 2012年 / 52卷 / 04期
关键词
Computer-assisted detection; Pulmonary embolism; Multislice computed tomography; Interobserver reliability; 3D analysis; AIDED DETECTION; CT ANGIOGRAPHY; RISK-FACTORS; EMBOLISM; HYPERTENSION; IMPACT;
D O I
10.1007/s00117-012-2304-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A recently developed CAD software which highlights intravascular thrombotic structures from multislice computed tomography (MSCT) data was tested regarding feasibility, interobserver reliability and effect on radiology reports. The CAD system ImageCheckerA (R) CT-Lung was tested in a randomized double-blinded study on 160 MSCT datasets (standardized technical conditions) performed for suspected pulmonary embolism (PE). The CAD data and images were analyzed by three radiologists in an independent and blinded fashion. The data from all 160 cases could be analyzed and 604 CAD prompts were set. Using the CAD analysis significantly more PEs were found in the peripheral pulmonary arterial circulation than described in the initial report. In 38 cases the 3 radiologists in consensus scored the images with the CAD adjunct as PE positive in peripheral vessels, which were initially reported as negative. Despite differences in the evaluation between two radiologists the amended assessment of the imaging data using the CAD softwear was reliable. There was a significant correlation between D-dimer values and the number of embolic structures detected by the CAD analysis. The recently developed CAD system is a useful adjunct as second reader to detect subtle emboli in peripheral vessels of MSCT datasets.
引用
收藏
页码:366 / 372
页数:7
相关论文
共 50 条
  • [41] Accuracy of computer-assisted pedicle screw placement - An in vivo computed tomography analysis
    Schwarzenbach, O
    Berlemann, U
    Jost, B
    Visarius, H
    Arm, E
    Langlotz, F
    Nolte, LP
    Ozdoba, C
    [J]. SPINE, 1997, 22 (04) : 452 - 458
  • [42] Multislice computed tomography for pulmonary embolism - A technological marvel
    Goldhaber, SZ
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (17): : 1812 - 1814
  • [43] Multislice Computed Tomography Assessment of Tracheobronchial Patterns in Partial Anomalous Left Pulmonary Artery
    Wang, Shi-Yu
    Gao, Wei
    Zhong, Yu-Min
    Sun, Ai-Min
    Wang, Qian
    Hu, Li-Wei
    Qiu, Hai-Sheng
    Li, Jian-Ying
    Jaffe, Richard B.
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2017, 41 (06) : 983 - 989
  • [44] SLICE GEOMETRY IN COMPUTER-ASSISTED TOMOGRAPHY
    BROOKS, RA
    DICHIRO, G
    [J]. NEURORADIOLOGY, 1978, 15 (02) : 123 - 123
  • [45] A STUDY OF COMPUTER-ASSISTED TOMOGRAPHY - INTRODUCTION
    ROTHMAN, RH
    [J]. SPINE, 1984, 9 (06) : 548 - 548
  • [46] COMPUTER-ASSISTED TOMOGRAPHY IN FAMILIAL LEUKODYSTROPHIES
    EIBEN, RM
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1977, 1 (02) : 270 - 271
  • [47] COMPUTER-ASSISTED TOMOGRAPHY OF URACHAL ABNORMALITIES
    SARNO, RC
    KLAUBER, G
    CARTER, BL
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1983, 7 (04) : 674 - 676
  • [48] HOLOGRAPHIC DISPLAYS FOR COMPUTER-ASSISTED TOMOGRAPHY
    GREGUSS, P
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1977, 1 (02) : 184 - 186
  • [49] COMPARISON OF COMPUTER-ASSISTED TOMOGRAPHY SCANNERS
    BROOKS, RA
    ALEXANDER, NE
    DICHIRO, G
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1977, 1 (02) : 252 - 253
  • [50] COMPUTER-ASSISTED TOMOGRAPHY IN INTRACRANIAL CYSTICERCOSIS
    WILSON, GH
    WINTER, J
    BENTSON, JR
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1977, 1 (02) : 260 - 260