Computer-assisted diagnostic procedure for multislice computed tomography for assessment of the pulmonary arterial circulation

被引:0
|
作者
Malich, A. [1 ]
Hentrich, D.
Hansch, A. [2 ]
Boettcher, J.
Teichgraeber, U. [2 ]
机构
[1] Sudharz Krankenhaus Nordhausen, Inst Radiol, D-99734 Nordhausen, Germany
[2] Univ Jena, Zentrum Radiol, D-6900 Jena, Germany
来源
RADIOLOGE | 2012年 / 52卷 / 04期
关键词
Computer-assisted detection; Pulmonary embolism; Multislice computed tomography; Interobserver reliability; 3D analysis; AIDED DETECTION; CT ANGIOGRAPHY; RISK-FACTORS; EMBOLISM; HYPERTENSION; IMPACT;
D O I
10.1007/s00117-012-2304-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A recently developed CAD software which highlights intravascular thrombotic structures from multislice computed tomography (MSCT) data was tested regarding feasibility, interobserver reliability and effect on radiology reports. The CAD system ImageCheckerA (R) CT-Lung was tested in a randomized double-blinded study on 160 MSCT datasets (standardized technical conditions) performed for suspected pulmonary embolism (PE). The CAD data and images were analyzed by three radiologists in an independent and blinded fashion. The data from all 160 cases could be analyzed and 604 CAD prompts were set. Using the CAD analysis significantly more PEs were found in the peripheral pulmonary arterial circulation than described in the initial report. In 38 cases the 3 radiologists in consensus scored the images with the CAD adjunct as PE positive in peripheral vessels, which were initially reported as negative. Despite differences in the evaluation between two radiologists the amended assessment of the imaging data using the CAD softwear was reliable. There was a significant correlation between D-dimer values and the number of embolic structures detected by the CAD analysis. The recently developed CAD system is a useful adjunct as second reader to detect subtle emboli in peripheral vessels of MSCT datasets.
引用
收藏
页码:366 / 372
页数:7
相关论文
共 50 条
  • [1] COMPUTER-ASSISTED METHOD TO DETERMINE DIAGNOSTIC EFFICACY OF COMPUTED TOMOGRAPHY OF BODY
    LEVITT, RG
    JOST, RG
    TRACHTMAN, J
    SAGEL, SS
    STANLEY, RJ
    [J]. RADIOLOGY, 1977, 123 (01) : 97 - 101
  • [2] Computed tomography with computer-assisted detection of pulmonary nodules in dogs and cats
    Niesterok, C.
    Piesnack, S.
    Koehler, C.
    Ludewig, E.
    Alef, M.
    Kiefer, I.
    [J]. TIERAERZTLICHE PRAXIS AUSGABE KLEINTIERE HEIMTIERE, 2015, 43 (06): : 381 - 388
  • [3] Computerassistiertes Diagnoseverfahren für die Mehrschichtcomputertomographie zur Beurteilung der pulmonalarteriellen StrombahnKlinische BedeutungComputer-assisted diagnostic procedure for multislice computed tomography for assessment of the pulmonary arterial circulationClinical relevance
    A. Malich
    D. Hentrich
    A. Hansch
    J. Böttcher
    U. Teichgräber
    [J]. Der Radiologe, 2012, 52 (4): : 366 - 372
  • [4] EVALUATION IN AN INPATIENT SETTING OF DTREE, A COMPUTER-ASSISTED DIAGNOSTIC-ASSESSMENT PROCEDURE
    FIRST, MB
    OPLER, LA
    HAMILTON, RM
    LINDER, J
    LINFIELD, LS
    SILVER, JM
    TOSHAV, NL
    KAHN, D
    WILLIAMS, JBW
    SPITZER, RL
    [J]. COMPREHENSIVE PSYCHIATRY, 1993, 34 (03) : 171 - 175
  • [5] COMPUTER-ASSISTED QUANTITATIVE-ANALYSIS OF COMPUTED TOMOGRAPHY
    BELANGER, MG
    YASNOFF, WA
    BACUS, JW
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1977, 1 (02) : 275 - 275
  • [8] Assessment of coronary arterial stents by multislice-computed tomography angiography
    Grude, M
    Maintz, D
    Paul, M
    Fischbach, R
    Breithardt, G
    Wichter, T
    [J]. EUROPEAN HEART JOURNAL, 2003, 24 : 329 - 329
  • [9] COMPUTER-ASSISTED TOMOGRAPHY
    DONIN, JF
    [J]. WESTERN JOURNAL OF MEDICINE, 1976, 124 (04): : 326 - 327
  • [10] COMPUTER-ASSISTED TOMOGRAPHY
    LLOYD, GAS
    WRIGHT, JE
    [J]. BRITISH MEDICAL JOURNAL, 1974, 3 (5923): : 114 - 115