Performance of the two-phase ejector expansion refrigeration cycle

被引:61
|
作者
Wongwises, S [1 ]
Disawas, S [1 ]
机构
[1] King Mongkuts Univ Technol Thonburi, Dept Engn Mech, Fluid Mech Thermal Engn & Multiphase Flow Res Lab, Bangkok 10140, Thailand
关键词
two-phase ejector; refrigeration; liquid-recirculation; coefficient of performance;
D O I
10.1016/j.ijheatmasstransfer.2005.04.017
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper is a continuation of the authors' previous work. The paper presents new experimental data of the system performance of the two-phase ejector refrigeration cycle (TPERC). The TPERC uses a two-phase ejector as an expansion device while the conventional refrigeration cycle (CRC) uses an expansion valve. The TPERC enables the evaporator to be flooded with refrigerant, resulting in a higher refrigerant-side heat transfer coefficient. The experimental study shows that the TPERC gives a higher cooling capacity and a higher coefficient of performance. Moreover, the pressure ratio and the discharge temperature of the compressor of the TPERC are lower than those of the CRC. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:4282 / 4286
页数:5
相关论文
共 50 条
  • [31] Experimental analysis on the effect of internal heat exchanger in transcritical CO2 refrigeration cycle with two-phase ejector
    Nakagawa, Masafumi
    Marasigan, Ariel R.
    Matsukawa, Takanori
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (07): : 1577 - 1586
  • [32] Preliminary study of a novel R718 refrigeration cycle with single stage centrifugal compressor and two-phase ejector
    Sarevski, Milan N.
    Sarevski, Vasko N.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2014, 40 : 435 - 449
  • [33] Experimental study of a two-phase ejector for CO2 transcritical refrigeration system
    Haberschill, Philippe
    Nehdi, Ezzeddine
    Kairouani, Lakdar
    Elakhdar, Mouna Abouda
    ARCHIVES OF THERMODYNAMICS, 2021, 42 (04) : 217 - 246
  • [34] A new CO 2 refrigeration system with two-phase ejector and parallel compression for supermarkets
    Tashtoush, Bourhan
    Sahli, Haythem
    Elakhdar, Mouna
    Megdouli, Karima
    Nehdi, Ezzedine
    HELIYON, 2024, 10 (05)
  • [35] Two-phase flow visualisation in the R744 vapour ejector for refrigeration systems
    Palacz, Michal
    Bodys, Jakub
    Haida, Michal
    Smolka, Jacek
    Nowak, Andrzej J.
    APPLIED THERMAL ENGINEERING, 2022, 210
  • [36] Experimental investigation on the malfunction characteristics of the two-phase ejector in a typical enhanced refrigeration system
    Bai, Tao
    Lu, Yu
    Wan, Jiahao
    Yu, Jianlin
    Applied Thermal Engineering, 2025,
  • [37] A high performance solar-assisted ejector expansion refrigeration cycle for residential air conditioning
    Zeinab Sajjadi S.
    Farhanieh B.
    Afshin H.
    Applied Thermal Engineering, 2024, 254
  • [38] INVESTIGATION OF THE EFFECT OF THE PRIMARY NOZZLE THROAT DIAMETER ON THE EVAPORATOR PERFORMANCE OF AN EJECTOR EXPANSION REFRIGERATION CYCLE
    Seckin, C.
    JOURNAL OF THERMAL ENGINEERING, 2018, 4 (03): : 1939 - 1953
  • [39] Cycle improvements to ejector-expansion transcritical CO2 two-stage refrigeration cycle
    Yari, M.
    Sirousazar, M.
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2008, 32 (07) : 677 - 687
  • [40] Application of an ejector in autocascade refrigeration cycle for the performance improvement
    Yu, Jianlin
    Zhao, Hua
    Li, Yanzhong
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (02): : 279 - 286