Experimental investigation on the malfunction characteristics of the two-phase ejector in a typical enhanced refrigeration system

被引:1
|
作者
Bai, Tao [1 ]
Lu, Yu [2 ]
Wan, Jiahao [1 ]
Yu, Jianlin [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Dept Refrigerat & Cryogen Engn, Xian 710049, Peoples R China
[2] TBEA Xian Elect Technol Co Ltd, Xian 710099, Peoples R China
关键词
Experimental investigation; Malfunction; Two-phase Ejector; Structural parameters; Operating conditions; PERFORMANCE;
D O I
10.1016/j.applthermaleng.2024.125204
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this paper, experimental research was conducted to explore ejector malfunctions caused by varying structural and operating parameters in the ejector outlet split ejector refrigeration system. Effective methods and strategies to mitigate ejector failure were proposed. The results indicated that inappropriate structural parameters led to ejector failure or instability. A smaller nozzle throat diameter and excessively large or small NXP values caused entrainment malfunction but not obvious pressure lift malfunctions. Conversely, a smaller mixing section diameter resulted in pressure lift malfunctions. The effect of the operating parameters on mass entrainment failures or instability was discussed. Smaller electronic expansion valve openings led to significant mass entrainment issues, and the ejector's instability became more pronounced with higher evaporator heat loads. The sensitivity of the electronic expansion valve opening to causing ejector malfunctions varied with different nozzle throat diameters. Throat diameters of 0.7 mm and 0.9 mm corresponded to TOP values of 10 % and 5 % for ejector failure, respectively. Strategies to address ejector entrainment malfunction or instability were studied. Increasing the electronic expansion valve opening effectively suppressed ejector failure, while merely adjusting compressor speed did not. A combined approach of increasing compressor speed and electronic expansion valve opening quickly resolved ejector malfunctions.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Experimental investigation on two-phase driven ejector performance in a novel ejector enhanced refrigeration system
    Wang, Xiao
    Yu, Jianlin
    ENERGY CONVERSION AND MANAGEMENT, 2016, 111 : 391 - 400
  • [2] Experimental investigation on the dynamic malfunction behavior of the two-phase ejector in a modified auto-cascade freezer refrigeration system
    Bai, Tao
    Yan, Gang
    Yu, Jianlin
    ENERGY CONVERSION AND MANAGEMENT, 2019, 183 : 382 - 390
  • [3] Experimental investigation of a two-phase ejector installed into the refrigeration system for performance enhancement
    Sutthivirode, Kittiwoot
    Thongtip, Tongchana
    ENERGY REPORTS, 2022, 8 : 7263 - 7273
  • [4] Experimental investigation of a two-phase ejector installed into the refrigeration system for performance enhancement
    Sutthivirode, Kittiwoot
    Thongtip, Tongchana
    ENERGY REPORTS, 2022, 8 : 7263 - 7273
  • [5] Experimental investigation of the improvement potential of dual evaporator based refrigeration system equipped with two-phase ejector
    Thongtip, Tongchana
    Amornsawaddirak, Teerapharp
    Singmai, Wichean
    Sutthivirode, Kittiwoot
    APPLIED THERMAL ENGINEERING, 2025, 268
  • [6] Experimental investigation on the performance of the refrigeration cycle using a two-phase ejector as an expansion device
    Disawas, S
    Wongwises, S
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2004, 27 (06): : 587 - 594
  • [7] Experimental study of a two-phase ejector for CO2 transcritical refrigeration system
    Haberschill, Philippe
    Nehdi, Ezzeddine
    Kairouani, Lakdar
    Elakhdar, Mouna Abouda
    ARCHIVES OF THERMODYNAMICS, 2021, 42 (04) : 217 - 246
  • [8] Experimental Investigation on Performance Characteristics of Two-Phase Flow Ejector for Application of Energy Conversion System
    Park, Sang Kyoo
    Yang, Hei Cheon
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2020, 44 (12) : 741 - 749
  • [9] An experimental investigation of ejector performance characteristics in a jet refrigeration system
    Huang, MC
    Chen, SL
    JOURNAL OF THE CHINESE INSTITUTE OF CHEMICAL ENGINEERS, 1996, 27 (02): : 91 - 100
  • [10] EXPERIMENTAL INVESTIGATION OF MOTIVE NOZZLE IN TWO-PHASE EJECTOR
    Karwacki, J.
    Dudar, A.
    Butrymowicz, D.
    Smierciew, K.
    23RD IIR INTERNATIONAL CONGRESS OF REFRIGERATION, 2011, 23 : 3040 - +