Experimental investigation on the malfunction characteristics of the two-phase ejector in a typical enhanced refrigeration system

被引:1
|
作者
Bai, Tao [1 ]
Lu, Yu [2 ]
Wan, Jiahao [1 ]
Yu, Jianlin [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Dept Refrigerat & Cryogen Engn, Xian 710049, Peoples R China
[2] TBEA Xian Elect Technol Co Ltd, Xian 710099, Peoples R China
关键词
Experimental investigation; Malfunction; Two-phase Ejector; Structural parameters; Operating conditions; PERFORMANCE;
D O I
10.1016/j.applthermaleng.2024.125204
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this paper, experimental research was conducted to explore ejector malfunctions caused by varying structural and operating parameters in the ejector outlet split ejector refrigeration system. Effective methods and strategies to mitigate ejector failure were proposed. The results indicated that inappropriate structural parameters led to ejector failure or instability. A smaller nozzle throat diameter and excessively large or small NXP values caused entrainment malfunction but not obvious pressure lift malfunctions. Conversely, a smaller mixing section diameter resulted in pressure lift malfunctions. The effect of the operating parameters on mass entrainment failures or instability was discussed. Smaller electronic expansion valve openings led to significant mass entrainment issues, and the ejector's instability became more pronounced with higher evaporator heat loads. The sensitivity of the electronic expansion valve opening to causing ejector malfunctions varied with different nozzle throat diameters. Throat diameters of 0.7 mm and 0.9 mm corresponded to TOP values of 10 % and 5 % for ejector failure, respectively. Strategies to address ejector entrainment malfunction or instability were studied. Increasing the electronic expansion valve opening effectively suppressed ejector failure, while merely adjusting compressor speed did not. A combined approach of increasing compressor speed and electronic expansion valve opening quickly resolved ejector malfunctions.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Effect of spindle position on the performance and two-phase characteristics of controllable ejector for transcritical CO2 refrigeration system
    Chandran, R. Jishnu
    Arumugam, Senthil Kumar
    Sadasivan, Sreeja
    John, Bibin
    Kanna, P. Rajesh
    JOURNAL OF SUPERCRITICAL FLUIDS, 2024, 205
  • [32] EXPERIMENTAL INVESTIGATION OF CONTROL STRATEGIES FOR OFF-DESIGN OPERATION OF A TRANSCRITICAL CO2 TWO-PHASE EJECTOR REFRIGERATION SYSTEM FOR THE COLD CHAIN
    Lawrence, Neal
    Elbel, Stefan
    4TH IIR INTERNATIONAL CONFERENCE ON SUSTAINABILITY AND THE COLD CHAIN, 2016, : 256 - 263
  • [33] Two-phase radial ejector for transcritical CO2 refrigeration
    Chandran Ramachandran, Jishnu
    Sadasivan, Sreeja
    Arumugam, Senthil Kumar
    Chen, Fei
    PHYSICS OF FLUIDS, 2024, 36 (12)
  • [34] Analysis of application of two-phase injector in ejector refrigeration systems for isobutane
    Smierciew, Kamil
    Butrymowicz, Dariusz
    Kwidzinski, Roman
    Przybylinski, Tomasz
    APPLIED THERMAL ENGINEERING, 2015, 78 : 630 - 639
  • [35] Experimental Investigation of the Improvement Potential of a Heat Pump Equipped with a Two-Phase Ejector
    Singmai, Wichean
    Onthong, Kasemsil
    Thongtip, Tongchana
    ENERGIES, 2023, 16 (16)
  • [36] Exergy analysis of operation of two-phase ejector in compression refrigeration systems
    Dudar, Adam
    Butrymowicz, Dariusz
    Smierciew, Kamil
    Karwacki, Jaroslaw
    ARCHIVES OF THERMODYNAMICS, 2013, 34 (04) : 107 - 122
  • [37] Experimental Investigation of the Ejector Refrigeration Cycle for Cascade System Application
    Hao, Xinyue
    Gao, Neng
    Chen, Guangming
    Volovyk, Oleksii
    Wang, Xuehui
    Xuan, Yongmei
    JOURNAL OF THERMAL SCIENCE, 2022, 31 (05) : 1476 - 1486
  • [38] Experimental Investigation of the Ejector Refrigeration Cycle for Cascade System Application
    HAO Xinyue
    GAO Neng
    CHEN Guangming
    VOLOVYK Oleksii
    WANG Xuehui
    XUAN Yongmei
    JournalofThermalScience, 2022, 31 (05) : 1476 - 1486
  • [39] Experimental Investigation on HFC134a Ejector Refrigeration System
    Zheng Hui-fan
    Fan Xiao-wei
    Li An-gui
    ICIEA: 2009 4TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOLS 1-6, 2009, : 2159 - +
  • [40] Experimental Investigation on Liquid-ring Ejector Refrigeration System
    Huang, Bi-Han
    Tang, Jian-Bo
    Zhou, Yuan
    Wang, Jun-Jie
    Ji, Wei
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2018, 39 (08): : 1643 - 1648