Experimental investigation on the malfunction characteristics of the two-phase ejector in a typical enhanced refrigeration system

被引:1
|
作者
Bai, Tao [1 ]
Lu, Yu [2 ]
Wan, Jiahao [1 ]
Yu, Jianlin [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Dept Refrigerat & Cryogen Engn, Xian 710049, Peoples R China
[2] TBEA Xian Elect Technol Co Ltd, Xian 710099, Peoples R China
关键词
Experimental investigation; Malfunction; Two-phase Ejector; Structural parameters; Operating conditions; PERFORMANCE;
D O I
10.1016/j.applthermaleng.2024.125204
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this paper, experimental research was conducted to explore ejector malfunctions caused by varying structural and operating parameters in the ejector outlet split ejector refrigeration system. Effective methods and strategies to mitigate ejector failure were proposed. The results indicated that inappropriate structural parameters led to ejector failure or instability. A smaller nozzle throat diameter and excessively large or small NXP values caused entrainment malfunction but not obvious pressure lift malfunctions. Conversely, a smaller mixing section diameter resulted in pressure lift malfunctions. The effect of the operating parameters on mass entrainment failures or instability was discussed. Smaller electronic expansion valve openings led to significant mass entrainment issues, and the ejector's instability became more pronounced with higher evaporator heat loads. The sensitivity of the electronic expansion valve opening to causing ejector malfunctions varied with different nozzle throat diameters. Throat diameters of 0.7 mm and 0.9 mm corresponded to TOP values of 10 % and 5 % for ejector failure, respectively. Strategies to address ejector entrainment malfunction or instability were studied. Increasing the electronic expansion valve opening effectively suppressed ejector failure, while merely adjusting compressor speed did not. A combined approach of increasing compressor speed and electronic expansion valve opening quickly resolved ejector malfunctions.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Experimental Investigation of the Performance and Spray Characteristics of a Supersonic Two-Phase Flow Ejector with Different Structures
    Li, Shizhen
    Li, Wei
    Liu, Yanjun
    Ji, Chen
    Zhang, Jingzhi
    ENERGIES, 2020, 13 (05)
  • [22] Influence of Structural Parameters of Two-Throat Nozzle Ejector on Performance of Two-phase Flow Ejector Refrigeration System
    Huang, Kang
    Guo, Xianmin
    Zhang, Peilan
    8TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY (ICAE2016), 2017, 105 : 5091 - 5097
  • [23] An Experimental Investigation on Vapor Compression Refrigeration System Cascaded with Ejector Refrigeration System
    Kumar, Vikas
    Sachdeva, Gulshan
    Tiwari, Sandeep
    Anuradha, Parinam
    Jain, Vaibhav
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2021, 29 (03)
  • [24] Performance of two-phase ejector in compression/ejection refrigeration cycle
    Wang, Fei
    Lü, Henglin
    Feng, Wei
    Shen, Shengqiang
    Huagong Xuebao/CIESC Journal, 2012, 63 (10): : 3094 - 3100
  • [25] An experimental investigation on a modified cascade refrigeration system with an ejector
    Li, Yunxiang
    Yu, Jianlin
    Qin, Hongqi
    Sheng, Zheng
    Wang, Qi
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 96 : 63 - 69
  • [26] EXPERIMENTAL INVESTIGATION OF EJECTOR REFRIGERATION SYSTEM WITH DOUBLE CONDENSERS
    Sait, H. H.
    Habibullah, B. A.
    Turkman, N.
    Ma, H. B.
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2018, VOL 6B, 2019,
  • [27] Experimental investigation and theoretical analysis of an ejector refrigeration system
    Pounds, Daniel A.
    Dong, J. M.
    Cheng, P.
    Ma, H. B.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2013, 67 : 200 - 209
  • [28] Experimental Investigation of an Ejector Refrigeration System with an Alternative Propellant
    Kuebel-Heising, Felix
    Repke, Jens-Uwe
    Raedle, Matthias
    CHEMIE INGENIEUR TECHNIK, 2019, 91 (09) : 1293 - 1301
  • [29] A new CO 2 refrigeration system with two-phase ejector and parallel compression for supermarkets
    Tashtoush, Bourhan
    Sahli, Haythem
    Elakhdar, Mouna
    Megdouli, Karima
    Nehdi, Ezzedine
    HELIYON, 2024, 10 (05)
  • [30] Performance analyses of novel two-phase ejector enhanced multi-evaporator refrigeration systems
    Sarkar, Jahar
    APPLIED THERMAL ENGINEERING, 2017, 110 : 1635 - 1642