Human Responses to the Thermal Comfort in Air-Conditioned Building: A Climate Chamber Study

被引:1
|
作者
Ismail, Ahmad Rasdan [1 ,2 ]
Jusoh, Norfadzilah [1 ]
Zein, Raemy Md [3 ]
机构
[1] Univ Malaysia Kelantan, Fac Creat Technol & Heritage, Bachok 16300, Kelantan, Malaysia
[2] Univ Malaysia Kelantan, Ctr Management Environm Occupat Safety & Hlth CMe, Bachok 16300, Kelantan, Malaysia
[3] Natl Inst Occupat Safety & Hlth NIOSH, Bandar Baru Bangi 43650, Selangor, Malaysia
来源
关键词
Thermal comfort; climate chamber; air conditioned; PMV; PPD index; HUMID TROPICS;
D O I
10.30880/ijie.2022.14.01.027
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
One of the challenges for engineers in designing comfort indoor environments is merging the need of energy savings and thermal comfort of the occupants. However, to assess complex heterogeneous environments created by novel building systems, there is a need for choosing more sophisticated and precise tools. There are many best ways to evaluate thermal comfort, at the same time the most cost and time-consuming one, various modelling tools are widely used. In this paper, we present a human climate chamber as a methodology for indoor environmental research, to predict the thermal comfort. Along with presenting this methodology, the human climate chamber was demonstrated on five supply temperature representing the indoor environment such as conditions for which thermal sensation was predicted with satisfactory accuracy. Based on the presented results, the overall thermal sensation on the body will be influenced mainly by those body segments that have a greatest thermal sensation under different condition's environment (supply temperature). The overall thermal comfort will follow the warmest environment (26 degrees C and 29 degrees C) and the coldest in a cool environment (19 degrees C and 23 degrees C). Furthermore, the overall thermal comfort will closely follow the parts of the body that feel the most uncomfortable in a cool or warm environment. The study found that supply temperature at the 23 degrees C indicates that the PMV is comfortable. The value of PMV in a supply temperature set at 23 degrees C is 0.26. This study contributes to the body knowledge of thermal comfort towards human in the building.
引用
收藏
页码:287 / 295
页数:9
相关论文
共 50 条
  • [41] Comparison of numerical simulation and experimental study on indoor air quality of air-conditioned office building in desert climate
    Wahhad, A. M.
    Adam, N. M.
    Sapuan, S. M.
    [J]. INTERNATIONAL JOURNAL OF AUTOMOTIVE AND MECHANICAL ENGINEERING, 2015, 12 : 3109 - 3124
  • [42] Field study of performance of solar chimney with air-conditioned building
    Khedari, J
    Rachapradit, N
    Hirunlabh, J
    [J]. ENERGY, 2003, 28 (11) : 1099 - 1114
  • [43] Effect of preferable wind directions on personal thermal comfort of occupants in the air-conditioned office in hot-humid climate
    Ilmiawan, Fakhrizal Akbar
    Zaki, Sheikh Ahmad
    Singh, Manoj Kumar
    Khalid, Waqas
    [J]. BUILDING AND ENVIRONMENT, 2024, 254
  • [44] Occupant perceptions on the thermal comfort guidelines in air-conditioned offices in Colombo, Sri Lanka
    Rodrigo, G. A.
    Perera, B. A. K. S.
    Ekanayake, B. J.
    [J]. INTERNATIONAL JOURNAL OF CONSTRUCTION MANAGEMENT, 2022, 22 (04) : 579 - 587
  • [45] A TALE OF 2 POPULATIONS - THERMAL COMFORT IN AIR-CONDITIONED AND NATURALLY VENTILATED OFFICES IN THAILAND
    BUSCH, JF
    [J]. ENERGY AND BUILDINGS, 1992, 18 (3-4) : 235 - 249
  • [46] Assessment of thermal comfort indices in an open air-conditioned stadium in hot and arid environment
    Ghani, Saud
    Mahgoub, Ahmed Osama
    Bakochristou, Foteini
    ElBialy, Esmail A.
    [J]. JOURNAL OF BUILDING ENGINEERING, 2021, 40
  • [47] The Relation between Clothing Insulation and Thermal Comfort of Occupants in Air-Conditioned Offices in Thailand
    Sikram, Tanadej
    Ichinose, Masayuki
    Sasaki, Rumiko
    [J]. SMART AND HEALTHY WITHIN THE TWO-DEGREE LIMIT (PLEA 2018), VOL 3, 2018, : 991 - 992
  • [48] An integrated approach to evaluate thermal comfort in air-conditioned large-space office
    Shan, Xiaofang
    Lu, Wei-Zhen
    [J]. SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2020, 27 (04) : 436 - 450
  • [49] CONSTRUCTION AND OPERATION OF A NATURALLY AIR-CONDITIONED BUILDING
    HAY, HR
    YELLOTT, JI
    [J]. MECHANICAL ENGINEERING, 1969, 91 (03) : 66 - &
  • [50] Wall/roof thermal performance differences between air-conditioned and non air-conditioned rooms
    Barrios, G.
    Huelsz, G.
    Rechtman, R.
    Rojas, J.
    [J]. ENERGY AND BUILDINGS, 2011, 43 (01) : 219 - 223