Optimized four-parameter PID controller for AVR systems with respect to robustness

被引:20
|
作者
Veinovic, Slavko [1 ,2 ]
Stojic, Djordje [2 ]
Joksimovic, Dusan [2 ]
机构
[1] Univ Belgrade, Sch Elect Engn, 73 Kralja Aleksandra, Belgrade, Serbia
[2] Univ Belgrade, Elect Inst Nikola Tesla, Automat & Control Dept, 8a Koste Glavinica, Belgrade, Serbia
关键词
PID controller; Excitation; Automatic voltage regulator; Load disturbance; Robustness; PERFORMANCE ANALYSIS; DESIGN;
D O I
10.1016/j.ijepes.2021.107529
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A procedure for the optimization of the proportional-integral-derivative (PID) controller under constraints to robustness of model uncertainties and sensitivity to measurement noise for a synchronous generator (SG) automatic voltage regulator (AVR) is presented in this paper. Performance indices related to the load disturbance response such as integral error (IE) and integral absolute error (IAE) are used as key criteria for the design method. They are minimized for a given maximum modulus of sensitivity function Ms. By maximizing loop gain regarding given sensitivities Ms and Mn we optimized load disturbance response. Contrary to majority AVR PID controller procedures, along with proportional, integral and derivative gain, a noise filter time constant is included in a proposed optimization algorithm to satisfy given sensitivity to the measurement noise Mn. A simple and effective solution of the optimization problem is obtained by binding a ratio between the integral and the derivative time constant Ti/Td. The optimal Ti/Td ratio is determined subsequently. Besides this, a step response to voltage reference change is modified with a reference filter to avoid large overshoots. This is achieved by limiting the maximum modulus of the resulting close-loop transfer function sensitivity Msp. The fact that zeros and poles of the second order reference filter have the same damping factor simplifies the procedure for resolving two out of six parameters. Also, two additional conditions result in the fact that three design parameters {Ms, Mn, Msp} are sufficient to determine the required six parameters of the two-degree-of-freedom (2DOF) PID controller. Such controller outperforms recently presented AVR controllers especially regarding the load disturbance rejection. Experiment tests with no-load SG and SG connected on the grid are carried out to prove the claims stated in this work concerning robustness performance and sensitivity to measurement noise. Also, we showed practical use of the proposed controller parameter tuning procedure by experimental runs performed on a lab generator.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] PI and PID controllers tuning for integral-type servo systems to ensure robust stability and controller robustness
    Radu-Emil Precup
    Stefan Preitl
    Electrical Engineering, 2006, 88 : 149 - 156
  • [32] A novel optimized fractional-order hybrid fuzzy intelligent PID controller for interconnected realistic power systems
    Haroun, A. H. Gomaa
    Li Yin-Ya
    TRANSACTIONS OF THE INSTITUTE OF MEASUREMENT AND CONTROL, 2019, 41 (11) : 3065 - 3080
  • [33] Fractional Order Sliding Mode PID Controller/Observer for Continuous Nonlinear Switched Systems with PSO Parameter Tuning
    Azar, Ahmad Taher
    Serrano, Fernando E.
    INTERNATIONAL CONFERENCE ON ADVANCED MACHINE LEARNING TECHNOLOGIES AND APPLICATIONS (AMLTA2018), 2018, 723 : 13 - 22
  • [34] JAYA Algorithm-Optimized Load Frequency Control of a Four-Area Interconnected Power System Tuning Using PID Controller
    Pahadasingh, Sunita
    Jena, Chitralekha
    Panigrahi, Chinmoy Kumar
    Ganthia, Bibhu Prasad
    ENGINEERING TECHNOLOGY & APPLIED SCIENCE RESEARCH, 2022, 12 (03) : 8646 - 8651
  • [35] A Novel Chaotic Particle Swarm Optimized Backpropagation Neural Network PID Controller for Four-Switch Buck-Boost Converters
    Ren, Luoyao
    Wang, Dazhi
    Yan, Xin
    Zhang, Yupeng
    Wang, Jiaxing
    ACTUATORS, 2024, 13 (11)
  • [36] A Particle Swarm Optimization tuned nonlinear PID controller with improved performance and robustness for First Order Plus Time Delay systems
    Charkoutsis, Stefanos
    Kara-Mohamed, Mohamed
    RESULTS IN CONTROL AND OPTIMIZATION, 2023, 12
  • [37] An Improved ACO Algorithm Optimized Fuzzy PID Controller for Load Frequency Control in Multi Area Interconnected Power Systems
    Chen, Gonggui
    Li, Zhijun
    Zhang, Zhizhong
    Li, Shuaiyong
    IEEE ACCESS, 2020, 8 : 6429 - 6447
  • [38] FUZZY aided PID controller is optimized by GA algorithm for Load Frequency Control of Multi-Source Power Systems
    Ahmadi, Sajjad
    Talami, Saeid Hojjati
    Sahnesaraie, Mostafa Andalib
    Dini, Fakbteh
    Tabernejadjozam, Bahareb
    Ashgevari, Yazdan
    2020 IEEE 18TH WORLD SYMPOSIUM ON APPLIED MACHINE INTELLIGENCE AND INFORMATICS (SAMI 2020), 2020, : 207 - 212
  • [39] Parameter Identification in Nonlinear Mechanical Systems with Noisy Partial State Measurement Using PID-Controller Penalty Functions
    Manikantan, R.
    Chakraborty, Sayan
    Uchida, Thomas K.
    Vyasarayani, C. P.
    MATHEMATICS, 2020, 8 (07)
  • [40] Frequency Regulation of Hybrid Distributed Power Systems Integrated with Renewable Sources by Optimized Type-2 Fuzzy PID Controller
    Nayak, Smrutiranjan
    Dash, Subhransu Sekhar
    Kar, Sanjeeb Kumar
    2021 9TH INTERNATIONAL CONFERENCE ON SMART GRID, ICSMARTGRID, 2021, : 259 - 263