Optimized four-parameter PID controller for AVR systems with respect to robustness

被引:20
|
作者
Veinovic, Slavko [1 ,2 ]
Stojic, Djordje [2 ]
Joksimovic, Dusan [2 ]
机构
[1] Univ Belgrade, Sch Elect Engn, 73 Kralja Aleksandra, Belgrade, Serbia
[2] Univ Belgrade, Elect Inst Nikola Tesla, Automat & Control Dept, 8a Koste Glavinica, Belgrade, Serbia
关键词
PID controller; Excitation; Automatic voltage regulator; Load disturbance; Robustness; PERFORMANCE ANALYSIS; DESIGN;
D O I
10.1016/j.ijepes.2021.107529
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A procedure for the optimization of the proportional-integral-derivative (PID) controller under constraints to robustness of model uncertainties and sensitivity to measurement noise for a synchronous generator (SG) automatic voltage regulator (AVR) is presented in this paper. Performance indices related to the load disturbance response such as integral error (IE) and integral absolute error (IAE) are used as key criteria for the design method. They are minimized for a given maximum modulus of sensitivity function Ms. By maximizing loop gain regarding given sensitivities Ms and Mn we optimized load disturbance response. Contrary to majority AVR PID controller procedures, along with proportional, integral and derivative gain, a noise filter time constant is included in a proposed optimization algorithm to satisfy given sensitivity to the measurement noise Mn. A simple and effective solution of the optimization problem is obtained by binding a ratio between the integral and the derivative time constant Ti/Td. The optimal Ti/Td ratio is determined subsequently. Besides this, a step response to voltage reference change is modified with a reference filter to avoid large overshoots. This is achieved by limiting the maximum modulus of the resulting close-loop transfer function sensitivity Msp. The fact that zeros and poles of the second order reference filter have the same damping factor simplifies the procedure for resolving two out of six parameters. Also, two additional conditions result in the fact that three design parameters {Ms, Mn, Msp} are sufficient to determine the required six parameters of the two-degree-of-freedom (2DOF) PID controller. Such controller outperforms recently presented AVR controllers especially regarding the load disturbance rejection. Experiment tests with no-load SG and SG connected on the grid are carried out to prove the claims stated in this work concerning robustness performance and sensitivity to measurement noise. Also, we showed practical use of the proposed controller parameter tuning procedure by experimental runs performed on a lab generator.
引用
收藏
页数:12
相关论文
共 50 条
  • [11] PID Controller Design for a Class of Distributed Parameter Systems
    Li Donghai
    Ji Yinghuang
    Li Mingda
    Liu Jinggong
    2011 30TH CHINESE CONTROL CONFERENCE (CCC), 2011, : 1021 - 1026
  • [12] Robustness with respect to delays for exponential stability of distributed parameter systems
    Rebarber, R
    Townley, S
    SIAM JOURNAL ON CONTROL AND OPTIMIZATION, 1998, 37 (01) : 230 - 244
  • [13] Q-Learning-Based Dumbo Octopus Algorithm for Parameter Tuning of Fractional-Order PID Controller for AVR Systems
    Li, Yuanyuan
    Ni, Lei
    Wang, Geng
    Aphale, Sumeet S.
    Zhang, Lanqiang
    MATHEMATICS, 2024, 12 (19)
  • [14] Robustness Analysis for PID Controller Optimized using PFPSO for Underactuated Gantry Crane System
    Hussien, S. Y. S.
    Ghazali, R.
    Jaafar, H. I.
    Soon, C. C.
    PROCEEDINGS 5TH IEEE INTERNATIONAL CONFERENCE ON CONTROL SYSTEM, COMPUTING AND ENGINEERING (ICCSCE 2015), 2015, : 520 - 525
  • [15] Transient stability analysis of power systems: Robustness with respect to parameter uncertainties
    Bretas, NG
    Alberto, LFC
    2002 IEEE POWER ENGINEERING SOCIETY WINTER MEETING, VOLS 1 AND 2, CONFERENCE PROCEEDINGS, 2002, : 1105 - 1112
  • [16] Application of the novel four-parameter discrete optimized grey model to forecast the wastewater discharged in Chongqing China
    Gou, Xiaoyi
    Zeng, Bo
    Gong, Ying
    ENGINEERING APPLICATIONS OF ARTIFICIAL INTELLIGENCE, 2022, 107
  • [17] Multi Objective Ant Algorithm to Parameter Optimized of PID Controller and Compare to Genetic Algorithm
    Kumar, Saurabh
    Bhatt, Rajesh
    2013 IEEE INTERNATIONAL CONFERENCE ON COMPUTATIONAL INTELLIGENCE AND COMPUTING RESEARCH (ICCIC), 2013, : 174 - 177
  • [18] PID controller design for distribution parameter systems based on genetic algorithms
    Chen, Xing
    Li, Donghai
    Qinghua Daxue Xuebao/Journal of Tsinghua University, 2007, 47 (08): : 1356 - 1360
  • [19] MPPT constraint conditions based on four-parameter cell model for some usual photovoltaic systems
    Li, Shaowu
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2024, 68
  • [20] Research on frequency robustness of multi-frequency electrical impedance tomography based on Four-Parameter Sine-fit algorithm
    Qiu, Maolin
    Hu, Xuehai
    PROCEEDINGS OF INTERNATIONAL CONFERENCE ON ALGORITHMS, SOFTWARE ENGINEERING, AND NETWORK SECURITY, ASENS 2024, 2024, : 296 - 300