Test-retest reliability of a portable monitor to assess energy expenditure

被引:0
|
作者
Brazeau, Anne-Sophie [1 ,2 ,3 ]
Karelis, Antony D. [2 ,4 ]
Mignault, Diane [2 ,5 ]
Lacroix, Marie-Josee [2 ]
Prud'homme, Denis [6 ]
Rabasa-Lhoret, Remi [1 ,2 ,3 ]
机构
[1] Montreal Clin Res Inst IRCM, Montreal, PQ, Canada
[2] Univ Montreal, Dept Nutr, Montreal, PQ H3T 1A8, Canada
[3] Univ Montreal Hosp Res Ctr CR CHUM, Montreal Diabet Res Ctr MDRC, Montreal, PQ H1W 4A4, Canada
[4] Univ Quebec, Dept Kinanthropol, Montreal, PQ H2X 3R9, Canada
[5] Montreal Clin Res Inst IRCM, Montreal, PQ H2W 1R7, Canada
[6] Univ Ottawa, Fac Hlth Sci, Sch Human Kinet, Ottawa, ON K1N 6N5, Canada
基金
加拿大健康研究院;
关键词
test-retest; activity monitoring; motion sensors; energy expenditure; accelerometer; physical activity; OBSTRUCTIVE PULMONARY-DISEASE; PHYSICAL-ACTIVITY; MULTISENSOR ARMBAND; WEIGHT-LOSS; EXERCISE; ADULTS; TECHNOLOGY; ACCURACY; SYSTEM; DEVICE;
D O I
10.1139/H11-016
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
The ability of the SenseWear Armband (SWA) to estimate energy expenditure (EE) in adults is established. However, except for resting metabolic rate, the test-retest reliability of the SWA for the estimation of EE in adults is unknown. To explore reliability, 34 healthy adults (50% women; age, 26.7 +/- 6.1 years; body mass index, 23.6 +/- 3.3 kg(.)m(-2)) completed a 2-day study protocol. During 13 h of direct supervision, subjects completed, each day, 60 min of lying awake rest, 30 min of structured sedentary activity, 45 min of walking circuit, and 45 min of ergocycling at 50% of their peak oxygen uptake. For the remaining 10 h, subjects remained seated. The SWA showed significant intraclass correlations between the 2 days of testing for the overall 13 h of direct supervision (r = 0.97; p < 0.001), the lying awake rest (r = 0.98; p < 0.001), the structured sedentary activity (r = 0.62; p < 0.05), the walking circuit (r = 0.95; p < 0.001), and the standardized physical activity (r = 0.85; p < 0.001). The results of this study indicate that the SWA is a reliable tool to estimate EE during multiple activities. These data provide additional evidence of the usefulness of the SWA in monitoring EE in healthy adults.
引用
收藏
页码:339 / 343
页数:5
相关论文
共 50 条
  • [31] Test-Retest Reliability of Electroglottography Measurement
    Cangi, Mehmet Emrah
    Yilmaz, Goksu
    JOURNAL OF ACADEMIC RESEARCH IN MEDICINE-JAREM, 2021, 11 (02): : 126 - 136
  • [32] INDEPENDENT SAMPLES AND TEST-RETEST RELIABILITY
    ROSEN, S
    AMERICAN SOCIOLOGIST, 1968, 3 (04): : 297 - 297
  • [33] ASSESSING TEST-RETEST RELIABILITY OF THE PORTABLE BROWER SPEED TRAP II TESTING SYSTEM
    Shalfawi, Shaher A. I.
    Enoksen, Eystein
    Tonnessen, Espen
    Ingebrigtsen, Jorgen
    KINESIOLOGY, 2012, 44 (01) : 24 - 30
  • [34] TEST-RETEST RELIABILITY OF THE SCHOOL AND COLLEGE ABILITY TEST
    TULLY, GE
    HALL, BW
    JOURNAL OF EDUCATIONAL MEASUREMENT, 1965, 2 (01) : 129 - 129
  • [35] THE TEST-RETEST RELIABILITY OF THE MCCARTHY SCREENING-TEST
    UMANSKY, W
    PAGET, KD
    COHEN, LR
    JOURNAL OF CLINICAL PSYCHOLOGY, 1981, 37 (03) : 650 - 654
  • [36] The Test-Retest Reliability of Indirect Calorimetry Measures of Energy Expenditure During Overground Walking in Older Adults With Mobility Limitations
    Wert, David M.
    VanSwearingen, Jessie M.
    Perera, Subashan
    Brach, Jennifer S.
    JOURNAL OF AGING AND PHYSICAL ACTIVITY, 2015, 23 (03) : 346 - 351
  • [37] THE TEST OF ORIENTATION FOR REHABILITATION PATIENTS - TEST-RETEST RELIABILITY
    DEITZ, JC
    TOVAR, VS
    BEEMAN, C
    THORN, DW
    TREVISAN, MS
    OCCUPATIONAL THERAPY JOURNAL OF RESEARCH, 1992, 12 (03): : 172 - 185
  • [38] Test-retest reliability of segment kinetic energy measures in the golf swing
    Outram, Tom
    Wheat, Jon
    SPORTS BIOMECHANICS, 2021, 20 (03) : 344 - 359
  • [39] TEST-RETEST RELIABILITY FOR HITTING ACCURACY TENNIS TEST
    Strecker, Estevam
    Foster, Ernest B.
    Pascoe, David D.
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2011, 25 (12) : 3501 - 3505
  • [40] THE TEST-RETEST RELIABILITY OF THE COMPREHENSIVE SYSTEM FOR THE RORSCHACH TEST
    DERUITER, C
    COHEN, L
    VANDERGRIJP, DN
    BINKHUYSEN, PJF
    INTERNATIONAL JOURNAL OF PSYCHOLOGY, 1992, 27 (3-4) : 345 - 350